1SDA056311R1 ABB E3S3200 PR123/P-LSIG 3200 A 3-Pole Fixed Air Circuit Breaker

1SDA056311R1 ABB E3S3200 PR123/P-LSIG 3200 A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA056311R1 E3S3200 is a 3200 A three-pole fixed SACE Emax air circuit breaker with a PR123/P-LSIG electronic overcurrent release, LSIG protection and rear horizontal terminals for high-current low-voltage power distribution.

SKU: 1SDA056311R1MPN: 1SDA056311R1
Price
List Price £32,096.64 ex VAT
Your Price (ex VAT) Save 25%
£24,072.48 25% OFF
You save £8,024.16 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £24,072.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£24,072.48

Why Choose the ABB 1SDA056311R1 E3S3200 Air Circuit Breaker?

The ABB 1SDA056311R1 is a high-performance SACE Emax E3S air circuit breaker (ACB) designed for protection and switching in demanding low-voltage electrical distribution systems. As part of the ABB New Emax E3 series, this three-pole fixed circuit breaker combines a 3200 A rated current with the advanced PR123/P-LSIG electronic overcurrent release for comprehensive protection of high-current industrial, commercial and infrastructure installations.

The E3S3200 is equipped with ABB's PR123/P-LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground-fault protection. This LSIG configuration provides comprehensive protection against overloads, short circuits and earth faults, making the breaker well suited to critical distribution systems requiring advanced electronic protection and selective coordination.

With a rated uninterrupted current of 3200 A, a three-pole fixed configuration and rear horizontal terminals, the 1SDA056311R1 is engineered for integration into high-current low-voltage switchboards. The E3S performance level provides a rated ultimate short-circuit breaking capacity of 75 kA at 400 V AC, making it suitable for installations with substantial prospective fault currents.

Key Advantages

  • High-performance ABB SACE Emax air circuit breaker for demanding low-voltage power distribution.
  • 3200 A rated uninterrupted current for high-current industrial and commercial applications.
  • PR123/P-LSIG electronic overcurrent release for advanced circuit protection.
  • LSIG functionality provides long-time, short-time, instantaneous and ground-fault protection.
  • 75 kA short-circuit breaking capacity at 400 V AC for systems with high prospective fault currents.
  • Three-pole fixed construction for permanent installation within low-voltage switchboards.
  • Rear horizontal terminals provide practical connection to switchboard busbars and conductors.
  • Four auxiliary change-over contacts and open/closed position indication support monitoring and control.

Key Features

  • ABB SACE Emax E3S3200 series air circuit breaker.
  • 3200 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed circuit-breaker version.
  • PR123/P-LSIG electronic overcurrent release.
  • LSIG protection covering long-time, short-time, instantaneous and ground-fault protection.
  • Rated operational voltage of 690 V AC.
  • 75 kA rated ultimate short-circuit breaking capacity at 400 V AC.
  • Adjustable overload protection from 1280–3200 A.
  • Adjustable instantaneous short-circuit protection from 4800–48000 A.
  • Rear horizontal terminals for main circuit connections.
  • Four auxiliary change-over contacts with circuit-breaker open/closed position indication.

Advanced Protection for High-Current Power Distribution

Air circuit breakers such as the ABB E3S3200 provide switching, isolation and protection for high-current low-voltage distribution systems. By detecting overload, short-circuit and ground-fault conditions, the electronic protection system enables the breaker to interrupt potentially damaging fault currents and help protect busbars, cables, transformers and connected electrical equipment.

The integrated PR123/P-LSIG electronic trip unit provides long-time, short-time, instantaneous and ground-fault protection for comprehensive fault management. Combined with the E3S breaker's 3200 A current rating and 75 kA short-circuit performance, the 1SDA056311R1 is particularly suited to main incomers, high-current feeders and critical distribution circuits requiring advanced protection.

Typical Applications

  • Low-voltage main distribution switchboards.
  • High-current industrial power distribution systems.
  • Manufacturing and process plants.
  • Large commercial building electrical distribution.
  • Main incomer and high-current feeder protection.
  • Generator and transformer distribution circuits.
  • Installations requiring ground-fault protection.
  • Power control centres and switchgear assemblies.
  • Infrastructure and utility installations.

Technical Specifications

Product group 310513-New Emax
Series SACE Emax / New Emax E3
ABB order code 1SDA056311R1
Product type Air circuit breaker
Frame / performance type E3S
Rated current (In) 3200 A
Rated uninterrupted current (Iu) 3200 A
Number of poles 3
Mounting version Fixed
Terminal arrangement Rear horizontal terminals
Trip unit PR123/P-LSIG electronic overcurrent release
Protection functions LSIG – long-time, short-time, instantaneous and ground fault
Integrated earth-fault protection Yes
Overload release setting range 1280–3200 A
Instantaneous short-circuit release setting range 4800–48000 A
Rated operational voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 75 kA
Current type AC
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Complete device with protection unit Yes
Motor drive Optional
DIN rail mounting No
Net weight 72 kg
EAN 8015644576516
Customs tariff number 85362090

Frequently Asked Questions

What is the ABB 1SDA056311R1 used for?

The ABB 1SDA056311R1 is an air circuit breaker used for switching and protecting high-current low-voltage electrical distribution circuits against overload, short-circuit and ground-fault conditions.

What is the rated current of the ABB E3S3200 1SDA056311R1?

The circuit breaker has a rated uninterrupted current of 3200 A, making it suitable for high-current power distribution applications.

What protection unit is fitted to this circuit breaker?

The 1SDA056311R1 is fitted with an ABB PR123/P-LSIG electronic overcurrent release, providing long-time, short-time, instantaneous and ground-fault protection functions.

What does LSIG protection mean?

LSIG denotes long-time overload protection, short-time short-circuit protection, instantaneous short-circuit protection and ground-fault protection, providing comprehensive protection for low-voltage distribution circuits.

What is the short-circuit breaking capacity of the ABB E3S3200?

The E3S performance level provides a rated ultimate short-circuit breaking capacity of 75 kA at 400 V AC, making it suitable for demanding installations with high prospective fault currents.

Is the ABB 1SDA056311R1 fixed or withdrawable?

The 1SDA056311R1 is a three-pole fixed air circuit breaker with rear horizontal terminals for permanent integration into compatible low-voltage switchboards.

Trusted ABB Power Distribution Technology

ABB SACE Emax air circuit breakers provide robust high-current switching and advanced electronic protection for demanding low-voltage distribution systems, combining high short-circuit performance with sophisticated protection and dependable switchgear integration.