Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB E3S2500PR121/P-LSIG is a 2500 A four-pole fixed SACE Emax air circuit breaker with rear horizontal terminals and a PR121/P-LSIG R2500 electronic trip unit providing long-time, short-time, instantaneous and earth-fault protection.
£18,796.23
The ABB E3S2500PR121/P-LSIG is a high-performance 2500 A four-pole air circuit breaker designed for reliable switching and comprehensive overcurrent protection in demanding low-voltage power distribution systems. Part of the established ABB SACE Emax New Emax series, this E3S breaker combines high short-circuit performance with the PR121/P-LSIG electronic overcurrent release.
The PR121/P-LSIG trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. These LSIG functions help protect cables, busbars, switchboards and connected electrical equipment against sustained overloads, severe short-circuit currents and earth faults, making the breaker suitable for critical industrial and commercial distribution networks.
With a rated uninterrupted current of 2500 A, a four-pole fixed configuration and rear horizontal terminals, ABB order code 1SDA056282R1 is designed for integration into high-current low-voltage switchboards. The breaker incorporates a PR121/P-LSIG R2500 overcurrent release, four auxiliary contacts and circuit-breaker open/closed position indication for monitoring and control integration.
Air circuit breakers such as the ABB E3S2500 provide switching and overcurrent protection for high-current low-voltage distribution circuits. The electronic trip release monitors circuit conditions and initiates breaker operation when configured protection thresholds are exceeded, helping protect cables, busbars, switchboards and connected electrical equipment against damaging overload, short-circuit and earth-fault currents.
The PR121/P-LSIG release combines four essential protection functions within a single electronic trip system. Together with the E3S frame's 75 kA short-circuit breaking capacity, 2500 A current rating, four-pole configuration and fixed rear-horizontal-terminal construction, this breaker is well suited to critical main distribution and high-current feeder applications requiring integrated earth-fault protection.
| Series | SACE Emax / New Emax |
|---|---|
| ABB order code | 1SDA056282R1 |
| Extended product type | E3S2500PR121/P-LSIGIn=2500A4pFHR |
| Product type | Air circuit breaker |
| Frame | E3S |
| Short-circuit performance level | S |
| Rated current | 2500 A |
| Rated operational current | 2500 A |
| Rated uninterrupted current | 2500 A |
| Number of poles | 4 |
| Current type | AC |
| Rated operational voltage | 690 V AC |
| Rated voltage | 690 V |
| Rated insulation voltage | 1000 V |
| Rated impulse withstand voltage | 12 kV |
| Rated ultimate short-circuit breaking capacity | 75 kA at 220–690 V AC |
| Rated service short-circuit breaking capacity | 75 kA at 220–690 V AC |
| Rated short-time withstand current | 75 kA for 1 s; 65 kA for 3 s |
| Execution | Fixed |
| Terminal arrangement | Rear horizontal terminals (HR) |
| Trip unit | PR121/P-LSIG |
| Release type | Electronic |
| Overcurrent release rating | R2500 |
| Protection functions | L, S, I and G |
| Integrated earth-fault protection | Yes |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Power loss | 205 W |
| Electrical durability | 8000 cycles at Ue ≤ 440 V; 7000 cycles at Ue 500–690 V |
| Maximum electrical operating frequency | 20 cycles per hour |
| Mechanical durability | 20,000 cycles |
| Maximum mechanical operating frequency | 60 cycles per hour |
| Dimensions (W × H × D) | 530 × 418 × 302 mm |
| Net weight | 76 kg |
| EAN | 8015644576226 |
| Customs tariff number | 85362090 |
| Standard | IEC |
It is a 2500 A four-pole air circuit breaker designed for switching and protecting high-current low-voltage AC power distribution circuits in industrial, commercial and infrastructure switchboards.
The PR121/P-LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.
The E3S2500 has a rated ultimate and service short-circuit breaking capacity of 75 kA across its specified operational-voltage range from 220 to 690 V AC, with a rated short-time withstand current of 75 kA for 1 s.
ABB order code 1SDA056282R1 is a fixed four-pole SACE Emax air circuit breaker equipped with rear horizontal terminals.
Yes. The G function of the PR121/P-LSIG electronic release provides integrated earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
ABB SACE Emax air circuit breakers are widely used in industrial and commercial low-voltage distribution systems, combining robust high-current switching technology with configurable electronic protection for dependable operation in demanding electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.