1SDA056165R1 ABB E3N3200 PR122/P-LSIG 3200A 3-Pole Withdrawable Air Circuit Breaker

1SDA056165R1 ABB E3N3200 PR122/P-LSIG 3200A 3-Pole Withdrawable Air Circuit Breaker

ABB 1SDA056165R1 is a SACE Emax E3N3200 three-pole withdrawable air circuit breaker moving part rated at 3200 A with a PR122/P-LSIG electronic overcurrent release for comprehensive high-current low-voltage circuit protection.

SKU: 1SDA056165R1Alt SKU: E3N 3200A 3P DRAWOMPN: 1SDA056165R1
Price
List Price £29,289.80 ex VAT
Your Price (ex VAT) Save 25%
£21,967.35 25% OFF
You save £7,322.45 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £21,967.35
Trade pricing is personalised to your account

Manufacturer Lead Time

£21,967.35

Why Choose the ABB E3N3200 PR122/P-LSIG 3200A 3-Pole Air Circuit Breaker?

The ABB E3N3200 PR122/P-LSIG, order code 1SDA056165R1, is a high-performance SACE Emax air circuit breaker (ACB) moving part designed for switching and protection in high-current low-voltage electrical distribution systems. As part of the ABB SACE Emax E3 series, this three-pole withdrawable breaker combines a 3200 A rated uninterrupted current with the advanced PR122/P-LSIG electronic overcurrent release.

The PR122/P-LSIG trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. This comprehensive LSIG protection configuration makes the breaker particularly suitable for critical power distribution applications where selective protection, fault coordination and reliable protection of high-current circuits are required.

With a 3200 A rated current, three-pole configuration and withdrawable moving-part construction, the E3N3200 is well suited to main switchboards, industrial distribution systems and high-current incomer and feeder applications. The E3N performance level provides rated ultimate and service short-circuit breaking capacities of 65 kA at 415 V AC, together with a rated short-time withstand current of 65 kA for 1 and 3 seconds.

Key Advantages

  • High-performance ABB SACE Emax air circuit breaker moving part for low-voltage power distribution.
  • 3200 A rated uninterrupted current for demanding high-current installations.
  • Three-pole configuration for three-phase electrical distribution systems.
  • Advanced PR122/P-LSIG electronic overcurrent release.
  • Comprehensive long-time, short-time, instantaneous and ground-fault protection.
  • 65 kA ultimate and service short-circuit breaking capacity at 415 V AC.
  • Withdrawable construction facilitates inspection, servicing and replacement.
  • Four auxiliary contacts support circuit-breaker status indication and control integration.

Key Features

  • ABB SACE Emax E3N3200 air circuit breaker moving part.
  • 3200 A rated uninterrupted current.
  • Three-pole (3P) configuration.
  • PR122/P-LSIG electronic overcurrent release.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Ground-fault protection (G).
  • Withdrawable (W) execution.
  • Moving part (MP) for the withdrawable SACE Emax system.
  • 690 V AC rated operational voltage.
  • 65 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • 65 kA rated service short-circuit breaking capacity at 415 V AC.
  • 65 kA rated short-time withstand current for 1 and 3 seconds.
  • Fitted with four auxiliary contacts and open/closed circuit-breaker position indication.

Reliable Circuit Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E3N3200 provide switching, isolation and overcurrent protection for high-current low-voltage distribution circuits. The electronic trip unit monitors current conditions and initiates circuit-breaker operation when configured protection thresholds are exceeded, helping protect cables, switchgear and connected electrical equipment from damaging electrical faults.

The PR122/P-LSIG release gives the E3N3200 multiple levels of protection for effective coordination within electrical distribution systems. Long-time protection responds to sustained overloads, short-time and instantaneous functions provide protection against short circuits, and the ground-fault function provides additional protection against earth-fault conditions.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • Manufacturing and process facilities.
  • High-current incomer and feeder protection.
  • Transformer and generator distribution systems.

Technical Specifications

Series SACE Emax E3
ABB order code 1SDA056165R1
Product group 310513-New Emax
Product type Air circuit breaker moving part
Frame / performance level E3N
Rated current 3200 A
Rated uninterrupted current 3200 A
Rated operational current 3200 A
Number of poles 3
Execution Withdrawable
Component Moving part (MP)
Trip unit PR122/P-LSIG
Release rating R3200
Release type Electronic
Protection functions LSIG
Long-time protection L
Short-time protection S
Instantaneous protection I
Ground-fault protection G
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 12 kV
Rated ultimate short-circuit breaking capacity at 415 V AC 65 kA
Rated service short-circuit breaking capacity at 415 V AC 65 kA
Rated short-time withstand current (1 s) 65 kA
Rated short-time withstand current (3 s) 65 kA
Power loss 570 W
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Electrical durability at ≤440 V 6000 cycles
Electrical durability at 500–690 V 5000 cycles
Mechanical durability 20,000 cycles
Dimensions (W × H × D) 432 × 461 × 396.5 mm
Net weight 64 kg
EAN 8015644575052
Customs tariff number 85362090
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA056165R1 used for?

The ABB 1SDA056165R1 is a SACE Emax E3N3200 air circuit breaker moving part designed for switching and protecting high-current low-voltage electrical distribution circuits.

What is the rated current of the ABB E3N3200 PR122/P-LSIG?

The E3N3200 has a rated uninterrupted current of 3200 A.

What protection functions does the PR122/P-LSIG trip unit provide?

The PR122/P-LSIG electronic overcurrent release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection.

What is the breaking capacity of the ABB E3N3200?

The E3N3200 has rated ultimate and service short-circuit breaking capacities of 65 kA at 415 V AC, together with a rated short-time withstand current of 65 kA for 1 and 3 seconds.

Is the ABB 1SDA056165R1 fixed or withdrawable?

The 1SDA056165R1 is a withdrawable three-pole circuit breaker moving part, allowing it to be withdrawn from its associated fixed part for inspection, servicing or replacement.