1SDA056164R1 ABB E3N3200PR122/P-LSI 3200A 3-Pole Air Circuit Breaker Moving Part

1SDA056164R1 ABB E3N3200PR122/P-LSI 3200A 3-Pole Air Circuit Breaker Moving Part

ABB E3N3200PR122/P-LSI is a 3200 A three-pole withdrawable SACE Emax air circuit breaker moving part with a PR122/P-LSI R3200 electronic trip unit providing long-time, short-time and instantaneous overcurrent protection.

SKU: 1SDA056164R1MPN: 1SDA056164R1
Price
List Price £28,032.37 ex VAT
Your Price (ex VAT) Save 25%
£21,024.28 25% OFF
You save £7,008.09 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £21,024.28
Trade pricing is personalised to your account

Manufacturer Lead Time

£21,024.28

Why Choose the ABB E3N3200PR122/P-LSI 3200A Air Circuit Breaker?

The ABB E3N3200PR122/P-LSI is a high-performance 3200 A three-pole air circuit breaker moving part designed for reliable switching and overcurrent protection in demanding low-voltage power distribution systems. As part of the established ABB SACE Emax New Emax series, this E3N configuration combines a robust high-current breaker frame with the advanced PR122/P-LSI electronic overcurrent release.

The PR122/P-LSI trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. These LSI protection functions help safeguard cables, busbars, switchboards and connected electrical equipment against sustained overloads and short-circuit faults while supporting selective protection and coordination within complex electrical distribution networks.

With a rated uninterrupted current of 3200 A, a three-pole withdrawable moving-part configuration and a PR122/P-LSI R3200 release, ABB order code 1SDA056164R1 is designed for integration into compatible SACE Emax withdrawable switchgear. The moving part is fitted with four auxiliary contacts and circuit-breaker open/closed position indication for effective monitoring and control integration.

Key Advantages

  • High-capacity 3200 A air circuit breaker moving part for low-voltage distribution.
  • Three-pole withdrawable configuration suitable for three-phase AC systems.
  • Advanced PR122/P-LSI R3200 electronic overcurrent release.
  • LSI functions provide long-time, short-time and instantaneous overcurrent protection.
  • 65 kA ultimate and service short-circuit breaking capacity throughout its specified operating-voltage range up to 690 V AC.
  • Withdrawable construction supports efficient inspection, maintenance and breaker replacement.
  • Four auxiliary contacts and open/closed position indication support switchboard monitoring and control.

Key Features

  • ABB SACE Emax E3N series.
  • 3200 A rated uninterrupted current.
  • Three-pole circuit-breaker configuration.
  • Withdrawable moving part (W MP).
  • PR122/P-LSI electronic trip unit.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • 690 V AC rated operational voltage.
  • Four auxiliary contacts with circuit-breaker open/closed position indication.

Reliable Protection for High-Current Power Distribution

Air circuit breakers such as the ABB E3N3200 provide switching and overcurrent protection for high-current low-voltage distribution circuits. The electronic trip release monitors circuit conditions and initiates breaker operation when configured protection thresholds are exceeded, helping protect cables, busbars, switchboards and connected electrical equipment against damaging overload and short-circuit currents.

The PR122/P-LSI release combines long-time, short-time and instantaneous protection functions in an electronic trip system. Together with the E3N frame's 65 kA short-circuit performance, 3200 A current rating and service-friendly withdrawable construction, this moving part is well suited to critical main distribution and high-current feeder applications.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process facilities.
  • Commercial and infrastructure electrical installations.
  • Incoming mains and high-current feeder protection.
  • Transformer secondary distribution systems.
  • Withdrawable ABB SACE Emax switchgear assemblies.

Technical Specifications

Series SACE Emax / New Emax
ABB order code 1SDA056164R1
Extended product type E3N3200PR122/P-LSIIn=3200A3pWMP
Product type Air circuit breaker moving part
Frame E3N
Short-circuit performance level N
Rated current 3200 A
Rated operational current 3200 A
Rated uninterrupted current 3200 A
Number of poles 3
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 12 kV
Rated ultimate short-circuit breaking capacity 65 kA
Rated service short-circuit breaking capacity 65 kA
Rated short-time withstand current 65 kA for 1 s / 3 s
Execution Withdrawable moving part (W MP)
Trip unit PR122/P-LSI
Release type Electronic
Overcurrent release rating R3200
Protection functions L, S and I
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Power loss 570 W
Electrical durability 6000 cycles at Ue ≤ 440 V; 5000 cycles at Ue 500–690 V
Maximum electrical operating frequency 20 cycles per hour
Mechanical durability 20,000 cycles
Maximum mechanical operating frequency 60 cycles per hour
Dimensions (W × H × D) 432 × 461 × 396.5 mm
Net weight 64 kg
EAN 8015644575045
Customs tariff number 85362090
Standard IEC

Frequently Asked Questions

What is the ABB E3N3200PR122/P-LSI used for?

It is a 3200 A three-pole air circuit breaker moving part designed for switching and protecting high-current low-voltage AC power distribution circuits in compatible ABB SACE Emax withdrawable switchgear.

What protection does the PR122/P-LSI trip unit provide?

The PR122/P-LSI electronic trip unit provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection.

What is the breaking capacity of ABB 1SDA056164R1?

The E3N3200 has a rated ultimate and service short-circuit breaking capacity of 65 kA throughout its specified operational-voltage range up to 690 V AC, together with a rated short-time withstand current of 65 kA.

Is ABB 1SDA056164R1 a fixed or withdrawable breaker?

ABB order code 1SDA056164R1 is a three-pole withdrawable moving part for a compatible SACE Emax E3N circuit-breaker installation.

Does the E3N3200PR122/P-LSI include auxiliary contacts?

Yes. This configuration is fitted with four auxiliary contacts together with circuit-breaker open/closed position indication for signalling and control applications.

Trusted by Electrical Professionals Worldwide

ABB SACE Emax air circuit breakers are widely used in industrial and commercial low-voltage distribution systems, combining robust high-current switching technology with configurable electronic protection and service-friendly withdrawable configurations for demanding electrical installations.