ABB 1SDA056149R1 is a SACE Emax E3N 3200 three-pole 3200 A fixed air circuit breaker with rear horizontal flat terminals and a PR122/P-LSIG R3200 electronic overcurrent release for comprehensive high-current low-voltage circuit protection.
£18,162.67
The ABB E3N3200 PR122/P-LSIG, order code 1SDA056149R1, is a high-current SACE Emax air circuit breaker designed for switching and protection in demanding low-voltage power distribution systems. Part of the ABB SACE Emax E3N series, this three-pole fixed circuit breaker is rated at 3200 A and incorporates the PR122/P-LSIG R3200 electronic overcurrent release.
The PR122/P-LSIG trip unit provides comprehensive long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection. This combination supports coordinated protection against overloads, short circuits and earth faults, helping safeguard cables, busbars, switchgear and connected equipment in high-current electrical distribution systems.
This E3N3200 configuration features a three-pole fixed execution with rear horizontal flat terminals. It has a rated operational voltage of 690 V AC, rated ultimate and service short-circuit breaking capacities of 65 kA across its specified AC voltage range, and a rated short-time withstand current of 65 kA, making it suitable for substantial industrial and infrastructure distribution systems.
Air circuit breakers such as the ABB SACE Emax E3N3200 provide switching and protection for high-current low-voltage distribution circuits. The electronic overcurrent release monitors electrical conditions and initiates breaker operation when configured protection thresholds are exceeded, helping protect cables, busbars, switchgear and connected electrical equipment.
The PR122/P-LSIG release combines long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection within an electronic trip unit. Together with the E3N frame's 3200 A current capability, 65 kA short-circuit performance and three-pole fixed construction, this configuration provides comprehensive protection for main distribution and high-current feeder circuits.
| Product family | SACE Emax |
|---|---|
| Series / frame | E3N 3200 |
| ABB order code | 1SDA056149R1 |
| Product type | Air circuit breaker |
| Rated current (In) | 3200 A |
| Rated operational current (Ie) | 3200 A |
| Rated uninterrupted current (Iu) | 3200 A |
| Number of poles | 3 |
| Trip unit | PR122/P-LSIG R3200 |
| Release type | Electronic |
| Protection functions | LSIG |
| Long-time protection | L |
| Short-time protection | S |
| Instantaneous protection | I |
| Earth-fault protection | G |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) | 65 kA at 220–690 V AC |
| Rated service short-circuit breaking capacity (Ics) | 65 kA at 220–690 V AC |
| Rated short-time withstand current (Icw) | 65 kA for 1 s and 3 s |
| Short-circuit performance level | N |
| Execution | Fixed |
| Terminal configuration | Rear horizontal flat terminals |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Electrical durability | 6000 cycles at ≤440 V; 5000 cycles at 500–690 V |
| Mechanical durability | 20,000 cycles |
| Power loss | 330 W |
| Dimensions (W × H × D) | 404 × 418 × 302 mm |
| Net weight | 60 kg |
| Standard | IEC |
| EAN | 8015644574895 |
| HS code | 85362090 |
| Product group | 310513-New Emax |
The ABB 1SDA056149R1 is a SACE Emax E3N 3200 three-pole fixed air circuit breaker rated at 3200 A, fitted with rear horizontal flat terminals and a PR122/P-LSIG R3200 electronic overcurrent release.
The circuit breaker has a rated operational and uninterrupted current of 3200 A, making it suitable for substantial high-current low-voltage power distribution applications.
LSIG denotes long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, providing comprehensive electronic protection against major distribution-system fault conditions.
The ABB 1SDA056149R1 is a three-pole air circuit breaker designed for three-phase low-voltage power distribution systems.
This model is a fixed air circuit breaker with rear horizontal flat terminals, intended for permanent installation within a compatible low-voltage switchboard.
Yes. Its PR122/P-LSIG electronic release includes the G earth-fault protection function in addition to long-time, short-time and instantaneous overcurrent protection.
ABB SACE Emax air circuit breakers are widely used in demanding low-voltage power distribution systems, providing dependable high-current switching and advanced electronic protection for industrial, commercial and infrastructure installations.