1SDA056137R1 ABB E3N2500 PR121/P-LSI 2500A 4P Withdrawable Air Circuit Breaker

1SDA056137R1 ABB E3N2500 PR121/P-LSI 2500A 4P Withdrawable Air Circuit Breaker

ABB 1SDA056137R1 SACE Emax E3N2500 four-pole withdrawable air circuit breaker moving part with a 2500 A rating, PR121/P-LSI electronic protection and 65 kA breaking capacity for demanding low-voltage power distribution.

SKU: 1SDA056137R1Alt SKU: E3MPMPN: 1SDA056137R1
Price
List Price £26,176.88 ex VAT
Your Price (ex VAT) Save 25%
£19,632.66 25% OFF
You save £6,544.22 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £19,632.66
Trade pricing is personalised to your account

Manufacturer Lead Time

£19,632.66

Why Choose the ABB E3N2500 PR121/P-LSI 2500A 4P Withdrawable Air Circuit Breaker?

The ABB 1SDA056137R1 is a high-performance SACE Emax E3N air circuit breaker (ACB) moving part designed for switching and protection in demanding low-voltage electrical distribution systems. Part of the ABB New Emax product group, this four-pole withdrawable circuit breaker combines a 2500 A rated uninterrupted current with the PR121/P-LSI R2500 electronic overcurrent release for dependable protection of industrial, commercial and infrastructure power networks.

The E3N2500 provides long-time, short-time and instantaneous protection through its LSI trip functionality. The PR121/P electronic release provides overload, delayed short-circuit and instantaneous short-circuit protection, supporting effective coordination and selectivity between protective devices. As an LSI configuration, this breaker does not include integrated earth-fault protection.

With a rated uninterrupted current of 2500 A, a 690 V AC rated operational voltage and an ultimate short-circuit breaking capacity of 65 kA at 415 V AC, the E3N2500 provides robust protection for high-current distribution systems. This version is a four-pole withdrawable moving part, allowing removal from a compatible ABB SACE Emax fixed part for inspection, testing, servicing or replacement.

Key Advantages

  • High-performance ABB SACE Emax E3N air circuit breaker moving part for high-current low-voltage distribution.
  • 2500 A rated uninterrupted current for demanding electrical installations.
  • Four-pole withdrawable configuration suitable for three-phase systems requiring neutral switching.
  • PR121/P-LSI R2500 electronic overcurrent release for overload and short-circuit protection.
  • LSI functionality provides long-time, short-time and instantaneous protection.
  • 65 kA Icu and Ics across the specified 220–690 V AC operating range.
  • 65 kA short-time withstand current for 1 s and 3 s supports robust system coordination.
  • Withdrawable moving-part construction facilitates inspection, testing, servicing and replacement.

Key Features

  • ABB SACE Emax E3N2500 air circuit breaker moving part.
  • 2500 A rated uninterrupted current.
  • Four-pole construction.
  • Withdrawable moving-part configuration.
  • PR121/P-LSI R2500 electronic overcurrent release.
  • Long-time, short-time and instantaneous (LSI) protection functions.
  • 690 V AC rated operational voltage.
  • 65 kA Icu at 220–690 V AC.
  • 65 kA Ics at 220–690 V AC.
  • 65 kA Icw for 1 s and 3 s.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Four auxiliary contacts.
  • Circuit-breaker open/closed position indication.

Reliable High-Current Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax E3N2500 provide switching, isolation and overcurrent protection at critical points within high-current low-voltage distribution systems. The E3 frame accommodates substantial continuous currents, while the N performance level provides dependable short-circuit interruption and short-time withstand capability for industrial switchboards, transformer-fed networks and other high-capacity distribution applications.

The PR121/P-LSI electronic trip unit provides long-time overload, short-time overcurrent and instantaneous short-circuit protection. Combined with the withdrawable Emax construction and 65 kA short-circuit performance, this configuration provides dependable electrical protection while allowing the circuit-breaker moving part to be removed from compatible switchgear for inspection, testing, maintenance or replacement.

Typical Applications

  • Main incoming circuit breakers in low-voltage switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • Manufacturing and process plants.
  • Transformer-fed distribution systems.
  • Generator distribution and protection systems.
  • High-current distribution feeder protection.
  • Four-pole distribution systems requiring neutral switching.
  • Withdrawable low-voltage switchgear and power distribution assemblies.

Technical Specifications

Series SACE Emax
Product group 310513-New Emax
ABB order code 1SDA056137R1
EAN 8015644574772
Customs tariff number 85362090
Product type Air circuit breaker moving part
Frame / size E3
Short-circuit performance level N
Rated current (In) 2500 A
Rated uninterrupted current (Iu) 2500 A
Rated operational current (Ie) 2500 A
Current type AC
Number of poles 4
Version Withdrawable moving part (W MP)
Trip unit PR121/P-LSI R2500
Release type Electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Integrated earth-fault protection No
Rated operational voltage 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 220–690 V AC 65 kA
Rated service short-circuit breaking capacity (Ics) at 220–690 V AC 65 kA
Rated short-time withstand current (Icw), 1 s 65 kA
Rated short-time withstand current (Icw), 3 s 65 kA
Auxiliary contacts 4
Position indication Circuit breaker open/closed
Mechanical durability 20,000 operating cycles
Maximum mechanical operating frequency 60 cycles per hour
Electrical durability at ≤440 V 8,000 operating cycles
Electrical durability at 500–690 V 7,000 operating cycles
Maximum electrical operating frequency 20 cycles per hour
Power loss 350 W
Dimensions (W × H × D) 558 × 461 × 396.5 mm
Net weight 81 kg
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA056137R1 used for?

The ABB 1SDA056137R1 is an E3N2500 withdrawable air circuit breaker moving part designed for switching and protecting high-current low-voltage electrical distribution systems against overload and short-circuit conditions.

What is the rated current of the ABB E3N2500 1SDA056137R1?

This circuit breaker has a rated uninterrupted current of 2500 A, making it suitable for high-current industrial, commercial and infrastructure power distribution applications.

What protection does the PR121/P-LSI trip unit provide?

The PR121/P-LSI electronic overcurrent release provides long-time overload, short-time overcurrent and instantaneous short-circuit protection. This LSI configuration does not include integrated earth-fault protection.

What is the breaking capacity of the ABB E3N2500?

The E3N2500 has a rated ultimate and service short-circuit breaking capacity of 65 kA across the specified 220–690 V AC operating range, with a rated short-time withstand current of 65 kA for 1 s and 3 s.

Is the ABB 1SDA056137R1 fixed or withdrawable?

The 1SDA056137R1 is a four-pole withdrawable circuit breaker moving part designed for use with a compatible ABB SACE Emax fixed part. The moving part and matching fixed part together form the complete withdrawable circuit-breaker assembly.

Trusted Protection from ABB

ABB SACE Emax air circuit breakers provide dependable switching and protection for demanding low-voltage power distribution systems, combining high continuous-current capability, robust short-circuit performance and service-friendly withdrawable construction for industrial, commercial and infrastructure applications.