1SDA056112R1 ABB E3N2500 PR121/P-LI 2500 A 3-Pole Fixed Air Circuit Breaker

1SDA056112R1 ABB E3N2500 PR121/P-LI 2500 A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA056112R1 is a SACE Emax E3N2500 three-pole fixed air circuit breaker rated at 2500 A with rear flat horizontal terminals and a PR121/P-LI R2500 electronic release providing long-time overload and instantaneous short-circuit protection.

SKU: 1SDA056112R1Alt SKU: E3N2500MPN: 1SDA056112R1
Price
List Price £16,802.56 ex VAT
Your Price (ex VAT) Save 25%
£12,601.92 25% OFF
You save £4,200.64 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,601.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,601.92

Why Choose the ABB E3N2500 PR121/P-LI 1SDA056112R1 Air Circuit Breaker?

The ABB 1SDA056112R1 is a robust SACE Emax E3N2500 air circuit breaker designed for switching and protection in high-current low-voltage electrical distribution systems. Part of the ABB New Emax range, this three-pole fixed circuit breaker has a rated uninterrupted current of 2500 A and incorporates the PR121/P-LI R2500 electronic overcurrent release.

The PR121/P-LI trip unit provides long-time overload and instantaneous short-circuit protection, helping protect conductors, switchgear, transformers and connected equipment against damaging overcurrent conditions. The E3N2500 provides a rated ultimate and service short-circuit breaking capacity of 65 kA across its specified AC voltage range.

With a rated operational voltage of up to 690 V AC, three-pole configuration and fixed construction with rear flat horizontal terminals, the E3N2500 is well suited to high-current switchboards and main distribution panels. Four auxiliary change-over contacts and circuit-breaker open/closed position indication support integration with switchboard control and signalling systems.

Key Advantages

  • Heavy-duty ABB SACE Emax air circuit breaker for high-current low-voltage distribution.
  • 2500 A rated uninterrupted current for demanding electrical installations.
  • PR121/P-LI R2500 electronic release provides overload and instantaneous short-circuit protection.
  • 65 kA Icu and Ics across the specified 220–690 V AC range.
  • 65 kA short-time withstand current for 1 s and 3 s.
  • Three-pole configuration suitable for three-phase distribution circuits.
  • Fixed construction with rear flat horizontal terminals for permanent switchboard installation.
  • Four auxiliary change-over contacts and open/closed position indication support control and signalling applications.

Key Features

  • ABB SACE Emax E3N2500 air circuit breaker.
  • 2500 A rated uninterrupted current.
  • Three-pole configuration.
  • PR121/P-LI R2500 electronic overcurrent release.
  • L protection: long-time overload protection.
  • I protection: instantaneous short-circuit protection.
  • 65 kA Icu/Ics at 220–690 V AC.
  • 65 kA Icw for 1 s and 3 s.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Fixed F version with rear flat horizontal terminals.
  • Fitted with four auxiliary change-over contacts.

Reliable Protection for Low-Voltage Distribution Systems

The ABB SACE Emax E3N2500 is engineered for high-current low-voltage distribution duties where dependable circuit protection and substantial short-circuit withstand capability are required. Its 2500 A rating and 65 kA short-circuit breaking capacity make it suitable for protecting major distribution circuits, switchboards, transformer-fed systems and industrial electrical installations.

The PR121/P-LI electronic release combines adjustable long-time overload protection with instantaneous short-circuit protection. Together with the fixed three-pole E3N platform and rear flat horizontal connection arrangement, these functions make the 1SDA056112R1 a practical solution for main incomers and high-current feeders requiring reliable electronic protection and permanent switchboard installation.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main electrical distribution panels.
  • Incoming mains and feeder protection.
  • Manufacturing and process industry electrical systems.
  • Commercial and infrastructure power distribution.
  • Transformer and installation protection.
  • High-current three-pole distribution circuits.

Technical Specifications

Product group 310513-New Emax
Series SACE Emax
Order code / MPN 1SDA056112R1
Product type Air circuit breaker
Frame / sub-type E3
Short-circuit performance level N
Rated current (In) 2500 A
Rated uninterrupted current (Iu) 2500 A
Rated operational current (Ie) 2500 A
Number of poles 3
Release PR121/P-LI
Release rating R2500
Release type Electronic
Protection functions LI
Long-time protection (L) Overload protection
Instantaneous protection (I) Instantaneous short-circuit protection
Integrated earth-fault protection No
Rated operational voltage 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) 65 kA at 220–690 V AC
Rated service short-circuit breaking capacity (Ics) 65 kA at 220–690 V AC
Rated short-time withstand current (Icw) 65 kA for 1 s
Overload release setting range 1000–2500 A
Instantaneous short-circuit release setting range 3750–37500 A
Version Fixed
Terminal connection Rear flat horizontal
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Motor drive Optional
Standard IEC
EAN 8015644574529
HS code 85362090

Frequently Asked Questions

What is the ABB 1SDA056112R1 used for?

The ABB 1SDA056112R1 is an E3N2500 SACE Emax air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution circuits.

What is the current rating of the ABB E3N2500 1SDA056112R1?

The circuit breaker has a rated uninterrupted current of 2500 A.

What protection does the PR121/P-LI release provide?

The PR121/P-LI electronic release provides long-time overload protection and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E3N2500 1SDA056112R1?

The circuit breaker has a rated ultimate short-circuit breaking capacity (Icu) and rated service short-circuit breaking capacity (Ics) of 65 kA across its specified 220–690 V AC range.

Is the ABB 1SDA056112R1 fixed or withdrawable?

The 1SDA056112R1 is a three-pole fixed air circuit breaker with rear flat horizontal terminals for permanent installation in a compatible low-voltage switchboard assembly.

Trusted ABB Power Distribution Technology

ABB SACE Emax air circuit breakers are engineered for dependable switching and protection in demanding low-voltage power distribution systems, combining high-current capability, electronic protection and robust construction for industrial, commercial and infrastructure electrical installations.