ABB 1SDA056099R1 is a SACE Emax E2L 1600 three-pole 1600 A withdrawable air circuit breaker moving part with a PR122/P-LI R1600 electronic overcurrent release for high-current low-voltage circuit protection.
£9,436.27
The ABB E2L1600 PR122/P-LI, order code 1SDA056099R1, is a high-performance SACE Emax air circuit breaker moving part designed for switching and protection in demanding low-voltage power distribution systems. As part of the ABB SACE Emax E2L series, this three-pole withdrawable circuit breaker is rated at 1600 A and incorporates the PR122/P-LI R1600 electronic overcurrent release.
The PR122/P-LI trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection, helping protect electrical distribution circuits against sustained overcurrents and severe short-circuit faults. Its electronic release provides adjustable protection for high-current applications while the E2L performance level delivers substantial short-circuit interruption capability.
This E2L1600 configuration is a three-pole withdrawable moving part for compatible SACE Emax switchgear. It is rated for operation at up to 690 V AC and provides an ultimate short-circuit breaking capacity of 130 kA at 400–415 V AC, combining high fault-handling capability with the serviceability benefits of withdrawable construction.
Air circuit breakers such as the ABB SACE Emax E2L1600 provide switching and protection for high-current low-voltage distribution circuits. The electronic overcurrent release monitors circuit current and initiates breaker operation when configured protection thresholds are exceeded, helping protect cables, busbars, switchgear and connected electrical equipment.
The PR122/P-LI release combines long-time overload and instantaneous short-circuit protection within an electronic trip unit. Together with the E2L frame's high fault-interruption capability and three-pole withdrawable construction, this configuration provides dependable protection for main distribution and feeder circuits while facilitating maintenance in compatible switchboard systems.
| Product family | SACE Emax |
|---|---|
| Series / frame | E2L 1600 |
| ABB order code | 1SDA056099R1 |
| Product type | Air circuit breaker moving part |
| Rated current (In) | 1600 A |
| Rated operational current (Ie) | 1600 A |
| Rated uninterrupted current (Iu) | 1600 A |
| Number of poles | 3 |
| Trip unit | PR122/P-LI R1600 |
| Release type | Electronic |
| Protection functions | LI |
| Long-time protection | L |
| Instantaneous protection | I |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate short-circuit breaking capacity (Icu) | 130 kA at 400–415 V AC |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 110 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Service short-circuit breaking capacity (Ics) | 130 kA at 400–415 V AC |
| Service short-circuit breaking capacity (Ics) at 690 V AC | 65 kA |
| Rated short-time withstand current (Icw) | 10 kA for 1 s |
| Short-circuit performance level | L |
| Execution | Withdrawable / moving part |
| Terminal connection type | Withdrawable circuit breaker |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Electrical durability | 3000 cycles at Ue ≤ 440 V; 2000 cycles at 500–690 V |
| Mechanical durability | 20,000 cycles |
| Power loss | 265 W |
| Dimensions (W × H × D) | 324 × 461 × 396.5 mm |
| Net weight | 49 kg |
| Standard | IEC |
| EAN | 8015644574390 |
| HS code | 85362090 |
| Product group | 310513-New Emax |
The ABB 1SDA056099R1 is a SACE Emax E2L 1600 three-pole withdrawable air circuit breaker moving part rated at 1600 A and equipped with a PR122/P-LI R1600 electronic overcurrent release.
The circuit breaker has a rated operational and uninterrupted current of 1600 A and is designed for high-current low-voltage power distribution applications.
LI denotes long-time overload protection and instantaneous short-circuit protection, helping protect the electrical system against sustained overcurrents and severe short-circuit faults.
The ABB 1SDA056099R1 is a three-pole air circuit breaker moving part designed for three-phase low-voltage power distribution systems.
This model is a withdrawable moving part of the SACE Emax E2L 1600 circuit breaker system and is intended for use within compatible withdrawable switchgear.
The breaker has an ultimate short-circuit breaking capacity of 130 kA at 400–415 V AC and 85 kA at 690 V AC.
ABB SACE Emax air circuit breakers are widely applied in demanding low-voltage power distribution systems, providing dependable high-current switching and advanced electronic protection for industrial, commercial and infrastructure installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.