ABB 1SDA056073R1 SACE Emax E2L1250 four-pole withdrawable air circuit breaker moving part with a 1250 A rating, PR121/P-LSI electronic protection and 130 kA breaking capacity at 415 V AC for demanding low-voltage power distribution.
£11,130.17
The ABB 1SDA056073R1 is a high-performance SACE Emax E2L air circuit breaker (ACB) moving part designed for protection and switching in demanding low-voltage electrical distribution systems. Part of the ABB New Emax product group, this four-pole withdrawable circuit breaker combines a 1250 A rated current with the PR121/P-LSI electronic overcurrent release for reliable protection of industrial, commercial and infrastructure power networks.
The E2L1250 provides long-time, short-time and instantaneous protection through its LSI trip functionality. The PR121/P electronic release offers adjustable overload and short-circuit protection settings, helping protect conductors and electrical equipment while supporting effective coordination and selectivity throughout complex low-voltage distribution systems.
With a rated uninterrupted current of 1250 A, a 690 V AC rated operational voltage and an ultimate short-circuit breaking capacity of 130 kA at 415 V AC, the E2L1250 is particularly suited to installations with high prospective fault currents. This version is a four-pole withdrawable moving part, allowing removal from a compatible ABB SACE Emax fixed part for inspection, testing, servicing or replacement.
Air circuit breakers such as the ABB Emax E2L1250 provide switching, isolation and overcurrent protection at critical points within high-current low-voltage distribution systems. The E2L performance level offers particularly high short-circuit interruption capability, making this breaker suitable for switchboards and distribution systems where substantial prospective fault currents may occur.
The PR121/P-LSI electronic trip unit provides long-time overload, short-time overcurrent and instantaneous short-circuit protection. Combined with the withdrawable Emax construction, this provides dependable electrical protection while allowing the circuit-breaker moving part to be removed from compatible switchgear for inspection, testing, maintenance or replacement.
| Series | SACE Emax |
|---|---|
| Product group | 310513-New Emax |
| ABB order code | 1SDA056073R1 |
| EAN | 8015644574130 |
| Product type | Air circuit breaker moving part |
| Frame / size | E2 |
| Performance level | L |
| Rated current (In) | 1250 A |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated operational current (Ie) | 1250 A |
| Current type | AC |
| Number of poles | 4 |
| Version | Withdrawable moving part (W MP) |
| Trip unit | PR121/P-LSI |
| Release type | Electronic |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Overload release adjustment range | 500–1250 A |
| Short-time delayed short-circuit release adjustment range | 1250–12500 A |
| Instantaneous short-circuit release adjustment range | 1875–18750 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 220–415 V AC | 130 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 110 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC | 85 kA |
| Rated service short-circuit breaking capacity (Ics) at 220–415 V AC | 130 kA |
| Rated service short-circuit breaking capacity (Ics) at 440 V AC | 110 kA |
| Rated service short-circuit breaking capacity (Ics) at 500–690 V AC | 65 kA |
| Rated short-time withstand current (Icw), 1 s | 10 kA |
| Auxiliary contacts | 4 change-over contacts |
| Position indication | Circuit breaker open/closed |
| Motor drive | Optional |
| Mechanical durability | 20,000 operating cycles |
| Electrical durability at ≤440 V | 4,000 operating cycles |
| Electrical durability at 500–690 V | 3,000 operating cycles |
| Power loss | 165 W |
| Dimensions (W × H × D) | 414 × 461 × 396.5 mm |
| Net weight | 61 kg |
| Standard | IEC |
The ABB 1SDA056073R1 is an E2L1250 withdrawable air circuit breaker moving part designed for switching and protecting high-current low-voltage electrical distribution systems against overload and short-circuit conditions.
This circuit breaker has a rated uninterrupted current of 1250 A, making it suitable for high-current industrial, commercial and infrastructure power distribution applications.
The PR121/P-LSI electronic overcurrent release provides long-time overload, short-time overcurrent and instantaneous short-circuit protection.
The E2L1250 has a rated ultimate short-circuit breaking capacity of 130 kA at 415 V AC, 110 kA at 440 V AC and 85 kA at 690 V AC.
The 1SDA056073R1 is a four-pole withdrawable circuit breaker moving part designed for use with a compatible ABB SACE Emax fixed part, allowing removal for inspection, testing, servicing or replacement.
ABB SACE Emax air circuit breakers are engineered for dependable switching and protection in demanding low-voltage power distribution systems, combining high short-circuit performance with electronic overcurrent protection and service-friendly withdrawable construction.
We use cookies