ABB E2L1250 1SDA056058R1 is a 1250 A four-pole fixed SACE Emax air circuit breaker with horizontal rear terminals and a PR121/P-LSIG electronic trip unit for overload, short-circuit and earth-fault protection.
£11,882.93
The ABB E2L1250 1SDA056058R1 is a high-performance SACE Emax air circuit breaker (ACB) designed for protection and switching in demanding high-current low-voltage electrical distribution systems. Part of the proven ABB SACE Emax E2 series, this four-pole fixed circuit breaker combines a 1250 A rated current with the PR121/P-LSIG electronic trip unit for comprehensive overload, short-time, instantaneous and earth-fault protection.
Designed for industrial, infrastructure and commercial power distribution applications, the E2L1250 provides exceptionally high short-circuit interruption performance. The PR121/P-LSIG electronic overcurrent release provides L, S, I and G protection functions, helping protect conductors, busbars and connected equipment against sustained overloads, short circuits and earth faults.
This model is a four-pole fixed circuit breaker with horizontal rear terminals for switchboard and busbar integration. The E2L performance level provides a rated ultimate short-circuit breaking capacity of 130 kA at 415 V AC, making it particularly suitable for distribution systems with very high prospective fault currents.
The ABB E2L1250 is engineered for low-voltage installations where exceptionally high prospective short-circuit currents require substantial interruption capability. With an ultimate breaking capacity of 130 kA at 415 V AC, this E2L configuration is well suited to main switchboards, transformer-fed distribution systems and industrial networks located close to high-capacity power sources.
The PR121/P-LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. Combined with the robust fixed SACE Emax platform and four-pole construction, this configuration provides comprehensive protection for critical three-phase and neutral low-voltage distribution circuits.
| Series | SACE Emax E2 |
|---|---|
| ABB order code | 1SDA056058R1 |
| Product group | 310513-New Emax |
| Product type | Air circuit breaker |
| Rated current (In) | 1250 A |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated operational current (Ie) | 1250 A |
| Number of poles | 4 |
| Execution | Fixed |
| Terminal arrangement | Horizontal rear terminals |
| Trip unit | PR121/P-LSIG electronic release |
| Protection functions | L, S, I, G |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate breaking capacity (Icu) at 400 V AC | 130 kA |
| Rated ultimate breaking capacity (Icu) at 415 V AC | 130 kA |
| Rated ultimate breaking capacity (Icu) at 440 V AC | 110 kA |
| Rated ultimate breaking capacity (Icu) at 500 V AC | 85 kA |
| Rated ultimate breaking capacity (Icu) at 690 V AC | 85 kA |
| Rated service breaking capacity (Ics) at 415 V AC | 130 kA |
| Rated service breaking capacity (Ics) at 690 V AC | 65 kA |
| Rated short-time withstand current (Icw), 1 s | 10 kA |
| Short-circuit performance level | L |
| Current type | AC |
| Power loss | 105 W |
| Electrical durability at ≤440 V | 4,000 cycles |
| Electrical durability at 500–690 V | 3,000 cycles |
| Mechanical durability | 20,000 cycles |
| Product dimensions (W × H × D) | 386 × 418 × 302 mm |
| Product net weight | 56 kg |
| EAN | 8015644573980 |
| Customs tariff number | 85362090 |
| Standard | IEC |
It is a 1250 A air circuit breaker designed for switching and comprehensive protection of demanding low-voltage electrical distribution systems.
This circuit breaker is equipped with an ABB PR121/P-LSIG electronic overcurrent release.
The LSIG configuration provides long-time overload, short-time, instantaneous short-circuit and earth-fault protection.
The E2L1250 provides a rated ultimate short-circuit breaking capacity of 130 kA at 415 V AC.
This model is a four-pole fixed air circuit breaker with horizontal rear terminals and a rated current of 1250 A.
ABB SACE Emax air circuit breakers are engineered for dependable protection and control of low-voltage power distribution systems, combining high breaking performance with electronic protection technology for demanding industrial, commercial and infrastructure installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.