ABB 1SDA056055R1 E2L1250 PR123/P-LSIG is a 1250 A three-pole fixed SACE Emax air circuit breaker with a PR123/P-LSIG R1250 electronic overcurrent release, rear horizontal terminals, four auxiliary contacts and open/closed position indication for demanding low-voltage power distribution systems.

SKU: 1SDA056055R1MPN: 1SDA056055R1
Price
List Price £19,859.36 ex VAT
Your Price (ex VAT) Save 25%
£14,894.52 25% OFF
You save £4,964.84 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £14,894.52
Trade pricing is personalised to your account

Manufacturer Lead Time

£14,894.52

Why Choose the ABB E2L1250 PR123/P-LSIG 1250A Air Circuit Breaker?

The ABB E2L1250 PR123/P-LSIG, order code 1SDA056055R1, is a high-performance three-pole fixed air circuit breaker (ACB) designed for switching and protection in demanding low-voltage electrical distribution systems. Part of the established ABB SACE Emax series, this E2L circuit breaker combines a rated current of 1250 A with the advanced PR123/P electronic overcurrent release for comprehensive protection in industrial, commercial and infrastructure power networks.

This configuration is supplied as a fixed three-pole circuit breaker with rear horizontal terminals. The fitted PR123/P-LSIG R1250 electronic overcurrent release provides long-time, short-time, instantaneous and ground-fault protection functions, helping protect electrical systems against sustained overloads, short circuits and earth faults while supporting selective protection coordination.

The E2L performance class is engineered for low-voltage installations requiring particularly high short-circuit interruption capability. Four auxiliary contacts and open/closed circuit-breaker position indication support remote signalling, monitoring and control, making this configuration well suited to critical high-current switchboards and power distribution assemblies.

Key Advantages

  • High-performance ABB SACE Emax E2L air circuit breaker for demanding low-voltage power distribution.
  • 1250 A rated current for substantial industrial and commercial electrical loads.
  • Three-pole fixed configuration for three-phase electrical distribution systems.
  • PR123/P-LSIG electronic overcurrent release for advanced circuit protection.
  • Long-time, short-time, instantaneous and ground-fault protection against multiple electrical fault conditions.
  • Rear horizontal terminals for practical integration into low-voltage switchboards.
  • Four auxiliary contacts support remote circuit-breaker status signalling and control.
  • E2L high-performance construction is suited to installations with demanding prospective short-circuit conditions.

Key Features

  • ABB SACE Emax E2L series.
  • 1250 A rated current.
  • Three-pole construction.
  • Fixed installation version.
  • Rear horizontal terminals (HR).
  • PR123/P electronic overcurrent release.
  • R1250 release rating.
  • LSIG protection: long-time, short-time, instantaneous and ground-fault.
  • Advanced electronic protection for selective low-voltage distribution systems.
  • Four auxiliary contacts for monitoring and control.
  • Open/closed circuit-breaker position indication.
  • High-performance E2L construction for critical power distribution applications.

Advanced Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax E2L1250 provide switching, isolation and protection for high-current low-voltage distribution circuits. The E2L performance class is intended for demanding applications where strong short-circuit interruption capability is required, making this breaker suitable for main distribution boards, incomers, feeders and other critical positions in industrial and infrastructure electrical networks.

The PR123/P electronic overcurrent release provides comprehensive LSIG protection for demanding electrical systems. Long-time protection responds to sustained overloads, short-time protection supports selective coordination during fault events, instantaneous protection provides rapid interruption of severe short circuits, and ground-fault protection helps detect potentially damaging earth-fault currents within the distribution network.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incomer and high-current feeder protection.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure installations.
  • Motor control centres and power distribution assemblies.
  • Transformer secondary and generator distribution circuits.
  • High fault-level systems requiring advanced LSIG electronic protection.

Technical Specifications

Series SACE Emax
ABB order code 1SDA056055R1
EAN 8015644573959
Product type Air circuit breaker (ACB)
Frame / performance level E2L
Performance class L
Rated current (In) 1250 A
Overcurrent release rating R1250
Number of poles 3
Current type AC
Installation version Fixed
Terminal configuration Rear horizontal terminals
Trip unit PR123/P
Release type Electronic
Protection functions LSIG
Long-time protection L
Short-time protection S
Instantaneous protection I
Ground-fault protection G
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Net weight 55 kg
HS code 85362090
ABB product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA056055R1 used for?

The ABB 1SDA056055R1 is a 1250 A three-pole fixed SACE Emax air circuit breaker designed for switching and protecting demanding low-voltage electrical distribution systems.

What protection functions does the PR123/P-LSIG trip unit provide?

The PR123/P-LSIG electronic overcurrent release provides long-time, short-time, instantaneous and ground-fault protection, commonly abbreviated as LSIG, covering overload, short-circuit and earth-fault conditions.

What is the rated current of the ABB E2L1250 PR123/P-LSIG?

The E2L1250 circuit breaker is fitted with an R1250 overcurrent release and has a rated current of 1250 A.

Is the ABB 1SDA056055R1 fixed or withdrawable?

The ABB 1SDA056055R1 is a fixed three-pole circuit breaker supplied with rear horizontal terminals.

What protection release is fitted to the ABB 1SDA056055R1?

The ABB 1SDA056055R1 is fitted with the PR123/P-LSIG R1250 electronic overcurrent release, providing long-time, short-time, instantaneous and ground-fault protection for demanding low-voltage distribution systems.

Trusted Protection for Critical Power Systems

ABB SACE Emax air circuit breakers are engineered for dependable low-voltage power distribution, combining high-current switching capability, advanced electronic LSIG protection and robust construction for critical industrial, commercial and infrastructure electrical systems.