ABB 1SDA056049R1 SACE Emax E2L1250 three-pole fixed air circuit breaker with a 1250 A rating, PR121/P-LSI electronic overcurrent protection and 130 kA breaking capacity at 415 V AC for demanding low-voltage power distribution.
£8,606.30
The ABB 1SDA056049R1 is a high-performance SACE Emax E2L air circuit breaker (ACB) designed for protection and switching in demanding low-voltage electrical distribution systems. As part of the ABB New Emax product group, this three-pole fixed circuit breaker combines a 1250 A rated current with the PR121/P-LSI electronic overcurrent release for reliable protection of industrial, commercial and infrastructure power networks.
The E2L1250 provides long-time, short-time and instantaneous protection through its LSI trip functionality. The PR121/P electronic release provides adjustable protection characteristics, helping protect conductors and equipment against overload and short-circuit conditions while supporting coordination and selectivity throughout low-voltage distribution systems.
With a rated uninterrupted current of 1250 A, a 690 V AC rated operational voltage and an ultimate short-circuit breaking capacity of 130 kA at 415 V AC, the E2L1250 offers exceptionally high fault-interruption performance. This version features a three-pole fixed configuration with rear horizontal terminals for permanent integration into electrical switchboards and power distribution assemblies.
Air circuit breakers such as the ABB Emax E2L1250 provide switching, isolation and overcurrent protection at critical points within high-current low-voltage distribution systems. The E2L performance level offers particularly high short-circuit breaking capability, making this circuit breaker suitable for installations where substantial prospective fault currents may occur.
The PR121/P-LSI electronic trip unit provides long-time overload, short-time overcurrent and instantaneous short-circuit protection. Adjustable protection settings allow the breaker to be coordinated with other protective devices throughout the electrical network, helping isolate faults while maintaining continuity of supply to unaffected circuits.
| Series | SACE Emax |
|---|---|
| Product group | 310513-New Emax |
| ABB order code | 1SDA056049R1 |
| EAN | 8015644573898 |
| Product type | Air circuit breaker |
| Frame / size | E2 |
| Short-circuit performance level | L |
| Rated current (In) | 1250 A |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated operational current (Ie) | 1250 A |
| Current type | AC |
| Number of poles | 3 |
| Installation | Fixed |
| Trip unit | PR121/P-LSI |
| Release type | Electronic |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Overload release adjustment range | 500–1250 A |
| Short-time delayed short-circuit release adjustment range | 1250–12500 A |
| Instantaneous short-circuit release adjustment range | 1875–18750 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 220–415 V AC | 130 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 110 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC | 85 kA |
| Rated service short-circuit breaking capacity (Ics) at 220–415 V AC | 130 kA |
| Rated service short-circuit breaking capacity (Ics) at 440 V AC | 110 kA |
| Rated service short-circuit breaking capacity (Ics) at 500–690 V AC | 65 kA |
| Rated short-time withstand current (Icw), 1 s | 10 kA |
| Terminal connection | Rear flat horizontal |
| Auxiliary contacts | 4 change-over contacts |
| Position indication | Circuit breaker open/closed |
| Motor drive | Optional |
| Mechanical durability | 20,000 operating cycles |
| Electrical durability at ≤440 V | 4,000 operating cycles |
| Electrical durability at 500–690 V | 3,000 operating cycles |
| Power loss | 105 W |
| Dimensions (W × H × D) | 296 × 418 × 302 mm |
| Net weight | 45 kg |
| Standard | IEC |
The ABB 1SDA056049R1 is an E2L1250 air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution systems against overload and short-circuit conditions.
This circuit breaker has a rated uninterrupted current of 1250 A, making it suitable for high-current industrial, commercial and infrastructure power distribution applications.
The PR121/P-LSI electronic overcurrent release provides long-time overload, short-time overcurrent and instantaneous short-circuit protection.
The E2L1250 has a rated ultimate short-circuit breaking capacity of 130 kA at 415 V AC, 110 kA at 440 V AC and 85 kA at 690 V AC.
The 1SDA056049R1 is a three-pole fixed circuit breaker with rear flat horizontal terminals, designed for permanent installation within a suitable low-voltage switchboard or power distribution assembly.
ABB SACE Emax air circuit breakers provide dependable switching and protection for demanding low-voltage power distribution systems, combining high short-circuit performance with electronic overcurrent protection for industrial, commercial and infrastructure applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.