1SDA056048R1 ABB E2L1250 PR121/P-LI 1250 A 3P Fixed Air Circuit Breaker

1SDA056048R1 ABB E2L1250 PR121/P-LI 1250 A 3P Fixed Air Circuit Breaker

ABB 1SDA056048R1 E2L1250 three-pole fixed air circuit breaker rated at 1250 A with rear horizontal terminals and a PR121/P-LI R1250 electronic release providing long-time overload and instantaneous short-circuit protection.

SKU: 1SDA056048R1MPN: 1SDA056048R1
Price
List Price £10,744.76 ex VAT
Your Price (ex VAT) Save 25%
£8,058.57 25% OFF
You save £2,686.19 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,058.57
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,058.57

Why Choose the ABB E2L1250 PR121/P-LI Air Circuit Breaker?

The ABB E2L1250 PR121/P-LI, order code 1SDA056048R1, is a high-performance three-pole fixed air circuit breaker (ACB) designed for demanding low-voltage power distribution and protection applications. Part of the ABB SACE Emax E2 series, it combines a rated current of 1250 A with the PR121/P-LI R1250 electronic overcurrent release and the high short-circuit performance of the E2L version.

The PR121/P-LI release provides long-time overload and instantaneous short-circuit protection, helping protect conductors, switchgear and connected equipment against sustained overcurrents and severe fault conditions. The electronic release offers adjustable protection settings, enabling the breaker to be configured for the requirements of industrial, commercial and infrastructure distribution systems.

This E2L1250 version features fixed construction with rear horizontal terminals, four auxiliary change-over contacts and open/closed circuit-breaker position indication. With a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 130 kA at 400/415 V AC, it is engineered for installations with particularly high prospective fault levels.

Key Advantages

  • High-performance ABB SACE Emax E2L air circuit breaker.
  • 1250 A rated uninterrupted current for high-current distribution systems.
  • Three-pole configuration for three-phase low-voltage networks.
  • PR121/P-LI R1250 electronic overcurrent release.
  • Long-time and instantaneous protection against overload and severe short-circuit conditions.
  • High 130 kA Icu at 400/415 V AC for demanding fault levels.
  • Fixed construction with rear horizontal terminals for switchboard integration.
  • Four change-over auxiliary contacts support signalling, monitoring and control functions.

Key Features

  • ABB SACE Emax E2L series.
  • 1250 A rated current.
  • Three-pole fixed air circuit breaker.
  • PR121/P-LI R1250 electronic release.
  • LI protection functions: Long-time and Instantaneous.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 130 kA Icu and Ics at 400/415 V AC.
  • Rear horizontal main terminals.
  • Four change-over auxiliary contacts.
  • Open/closed circuit-breaker position indication.
  • Optional motor operating mechanism capability.

High-Breaking-Capacity Protection for Critical Distribution

The ABB SACE Emax E2L1250 is designed for low-voltage installations where high prospective short-circuit currents demand substantial interruption capability. Its E2L performance level delivers an ultimate breaking capacity of 130 kA at 400/415 V AC, making it particularly suitable for high-capacity main distribution boards, transformer-fed systems and demanding industrial switchgear.

The PR121/P-LI electronic release provides long-time protection against sustained overloads together with instantaneous protection against severe short circuits. Combined with fixed rear-horizontal-terminal construction, four auxiliary change-over contacts and open/closed position indication, the E2L1250 provides robust protection and straightforward integration into suitably designed ABB Emax switchgear.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plant switchgear.
  • Commercial and infrastructure electrical distribution.
  • Transformer secondary protection.
  • Generator and standby power installations.
  • High-current incoming and feeder protection.
  • Installations with high prospective short-circuit fault levels.

Technical Specifications

Series SACE Emax E2
ABB order code 1SDA056048R1
Product type Air circuit breaker
Short-circuit performance level L
Number of poles 3
Rated current (In) 1250 A
Rated uninterrupted current (Iu) 1250 A
Rated operational current (Ie) 1250 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Trip unit PR121/P-LI R1250
Release type Electronic
Protection functions LI – Long-time and Instantaneous
Overload release current setting 500–1250 A
Instantaneous short-circuit release adjustment range 1875–18750 A
Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 130 kA
Service short-circuit breaking capacity (Ics) at 400/415 V AC 130 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 110 kA
Service short-circuit breaking capacity (Ics) at 440 V AC 110 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 65 kA
Rated short-time withstand current (Icw), 1 s 10 kA
Installation Fixed
Terminal arrangement Rear horizontal
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Integrated earth-fault protection No
Motor operating mechanism Optional
Power loss 105 W
Mechanical durability 20,000 cycles
Standard IEC
Weight 55 kg
EAN 8015644573881

Frequently Asked Questions

What is the ABB 1SDA056048R1?

The ABB 1SDA056048R1 is a three-pole fixed SACE Emax E2L1250 air circuit breaker rated at 1250 A, equipped with rear horizontal terminals and a PR121/P-LI R1250 electronic overcurrent release.

What protection functions does the PR121/P-LI provide?

The PR121/P-LI provides long-time overload protection and instantaneous short-circuit protection.

What is the rated current of ABB 1SDA056048R1?

The E2L1250 has a rated uninterrupted current of 1250 A and uses a three-pole configuration.

Is ABB 1SDA056048R1 fixed or withdrawable?

ABB 1SDA056048R1 is a fixed air circuit breaker with rear horizontal main terminals for integration into suitable low-voltage switchgear.

What is the breaking capacity of the E2L1250?

This E2L1250 configuration provides an ultimate short-circuit breaking capacity of 130 kA at 400/415 V AC and 85 kA at 690 V AC.

Trusted Protection for Critical Power Systems

ABB SACE Emax air circuit breakers combine high short-circuit performance, electronic overcurrent protection and robust switchgear integration to provide dependable switching and protection for demanding low-voltage power distribution systems.