1SDA056040R1 ABB E2S 2000 PR121/P-LI 2000 A 4-Pole Withdrawable Air Circuit Breaker

1SDA056040R1 ABB E2S 2000 PR121/P-LI 2000 A 4-Pole Withdrawable Air Circuit Breaker

ABB 1SDA056040R1 is a SACE Emax E2S 2000 A four-pole withdrawable air circuit breaker moving part with a PR121/P-LI R2000 electronic overcurrent release providing long-time overload and instantaneous short-circuit protection.

SKU: 1SDA056040R1MPN: 1SDA056040R1
Price
List Price £20,881.42 ex VAT
Your Price (ex VAT) Save 25%
£15,661.07 25% OFF
You save £5,220.36 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £15,661.07
Trade pricing is personalised to your account

Manufacturer Lead Time

£15,661.07

Why Choose the ABB E2S 2000 PR121/P-LI 1SDA056040R1 Air Circuit Breaker?

The ABB 1SDA056040R1 is a high-performance SACE Emax E2S 2000 air circuit breaker moving part designed for reliable switching and overcurrent protection in demanding low-voltage electrical distribution systems. This four-pole withdrawable circuit breaker moving part is equipped with the PR121/P-LI R2000 electronic overcurrent release, combining a high continuous-current rating with dependable electronic protection.

With a rated uninterrupted current of 2000 A and a rated operational voltage of up to 690 V AC, the E2S 2000 is suitable for main distribution switchboards, industrial installations, transformer protection and commercial power infrastructure. The PR121/P-LI electronic trip unit provides long-time overload and instantaneous short-circuit protection for conductors, switchgear and connected equipment.

The E2S performance level provides high short-circuit interruption capability, including a rated ultimate short-circuit breaking capacity of 85 kA at 220 V AC and a rated short-time withstand current of 65 kA for 1 s. This version is supplied as a four-pole withdrawable moving part (W MP) fitted with four auxiliary contacts and open/closed circuit-breaker position indication.

Key Advantages

  • Heavy-duty 2000 A air circuit breaker moving part for high-current low-voltage power distribution.
  • Four-pole configuration suitable for systems requiring phase and neutral switching.
  • High E2S S-performance short-circuit capability for demanding electrical installations.
  • Advanced PR121/P-LI R2000 electronic overcurrent release.
  • LI protection provides long-time overload and instantaneous short-circuit protection.
  • Withdrawable moving-part construction supports convenient inspection, servicing and replacement.
  • Part of the proven ABB SACE Emax E2S air circuit breaker platform.

Key Features

  • ABB SACE Emax E2S 2000 series.
  • 2000 A rated uninterrupted current.
  • Four-pole configuration.
  • Withdrawable moving-part execution.
  • PR121/P-LI R2000 electronic trip unit.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 65 kA short-time withstand current for 1 s.
  • Four auxiliary contacts.
  • Open/closed circuit-breaker position indication.

Electronic LI Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E2S provide switching, isolation and overcurrent protection for high-current low-voltage distribution circuits. The E2S 2000 combines substantial continuous-current capability with high short-circuit performance, making it suitable for main switchboards, industrial distribution systems and other installations where dependable fault interruption is essential.

The PR121/P-LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. Combined with the four-pole withdrawable SACE Emax construction, the 1SDA056040R1 provides dependable electronic protection while allowing the circuit breaker moving part to be withdrawn from its compatible fixed portion for inspection, maintenance or replacement.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Transformer protection and distribution.
  • Generator and utility distribution systems.
  • Manufacturing and process plant switchgear.
  • Commercial and infrastructure electrical distribution.
  • Four-pole installations requiring withdrawable circuit-breaker construction.

Technical Specifications

Product family SACE Emax
Series E2S
ABB order code 1SDA056040R1
Product group 310513-New Emax
Product type Air circuit breaker moving part
Rated uninterrupted current (Iu) 2000 A
Rated operational current (Ie) 2000 A
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 4
Execution Withdrawable moving part (W MP)
Trip unit PR121/P-LI R2000
Release type Electronic overcurrent release
Protection functions LI – long-time overload and instantaneous short-circuit protection
Short-circuit performance level S
Rated ultimate short-circuit breaking capacity (Icu) at 220 V AC 85 kA
Rated service short-circuit breaking capacity (Ics) at 220 V AC 85 kA
Rated short-time withstand current (Icw), 1 s 65 kA
Auxiliary contacts 4
Position indication Open / closed
Product depth 396.5 mm
Net weight 73 kg
EAN 8015644573805

Frequently Asked Questions

What is the ABB 1SDA056040R1 used for?

The ABB 1SDA056040R1 is a 2000 A four-pole air circuit breaker moving part designed for switching and electronic overcurrent protection in demanding low-voltage electrical distribution systems.

What is the current rating of the ABB E2S 2000 1SDA056040R1?

The ABB 1SDA056040R1 has a rated uninterrupted current of 2000 A, making it suitable for high-current industrial, commercial and infrastructure power distribution applications.

What protection does the PR121/P-LI trip unit provide?

The PR121/P-LI electronic trip unit provides LI protection functions consisting of long-time overload protection and instantaneous short-circuit protection.

What is the short-circuit performance of the ABB E2S 2000?

The E2S 2000 is an S-performance air circuit breaker. For this configuration, the rated ultimate and service short-circuit breaking capacities are 85 kA at 220 V AC, while the rated short-time withstand current is 65 kA for 1 s.

Is the ABB 1SDA056040R1 fixed or withdrawable?

The ABB 1SDA056040R1 is a four-pole withdrawable moving part (W MP) designed for use with a compatible SACE Emax withdrawable fixed part.

Trusted for Industrial Power Distribution

ABB SACE Emax air circuit breakers are engineered to provide dependable switching, isolation and electronic protection in demanding low-voltage power distribution systems, making the E2S 2000 a robust solution for industrial, commercial and infrastructure installations.