Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA056019R1 E2S2000 PR122/P-LI is a 2000 A three-pole fixed SACE Emax air circuit breaker with an R2000 LI electronic overcurrent release, 85 kA breaking capacity at 415 V AC and horizontal rear terminals for demanding low-voltage power distribution systems.
£11,162.59
The ABB E2S2000 PR122/P-LI, order code 1SDA056019R1, is a high-performance three-pole fixed air circuit breaker (ACB) designed for switching and protection in demanding low-voltage electrical distribution systems. Part of the established ABB SACE Emax series, this E2S circuit breaker combines a rated current of 2000 A with the PR122/P electronic overcurrent release for dependable protection in industrial, commercial and infrastructure power networks.
This configuration is supplied as a fixed three-pole circuit breaker with horizontal rear terminals. The fitted PR122/P-LI R2000 electronic overcurrent release provides long-time and instantaneous protection functions, helping protect electrical systems against sustained overloads and severe short-circuit faults while providing a robust solution for high-current switchboard applications.
The E2S performance level provides an ultimate and service short-circuit breaking capacity of 85 kA at 415 V AC and 65 kA at 690 V AC, together with a short-time withstand current of 65 kA for 1 s. Four auxiliary contacts and open/closed circuit-breaker position indication support status signalling, monitoring and integration into low-voltage power distribution assemblies.
Air circuit breakers such as the ABB SACE Emax E2S2000 provide switching, isolation and protection for high-current low-voltage distribution circuits. The E2S performance class combines high short-circuit interruption capability with robust short-time withstand performance, making this breaker suitable for main distribution boards, incomers, feeders and other critical positions where substantial prospective fault currents may be present.
The PR122/P electronic overcurrent release provides LI protection for demanding electrical networks. Long-time protection responds to sustained overload conditions, while instantaneous protection rapidly interrupts severe short-circuit currents to help safeguard conductors, switchgear, transformers and connected electrical equipment.
| Series | SACE Emax |
|---|---|
| ABB order code | 1SDA056019R1 |
| EAN | 8015644573591 |
| Product type | Air circuit breaker (ACB) |
| Frame / performance level | E2S |
| Short-circuit performance level | S |
| Rated current (In) | 2000 A |
| Rated operational current (Ie) | 2000 A |
| Rated uninterrupted current (Iu) | 2000 A |
| Number of poles | 3 |
| Current type | AC |
| Installation version | Fixed |
| Terminal configuration | Horizontal rear terminals |
| Trip unit | PR122/P |
| Overcurrent release rating | R2000 |
| Release type | Electronic |
| Protection functions | LI |
| Long-time protection | L |
| Instantaneous protection | I |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V |
| Rated impulse withstand voltage | 12 kV |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 85 kA |
| Service short-circuit breaking capacity (Ics) at 400 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 85 kA |
| Service short-circuit breaking capacity (Ics) at 415 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 85 kA |
| Service short-circuit breaking capacity (Ics) at 440 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 65 kA |
| Service short-circuit breaking capacity (Ics) at 500 V AC | 65 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 65 kA |
| Service short-circuit breaking capacity (Ics) at 690 V AC | 65 kA |
| Short-time withstand current (Icw) for 1 s | 65 kA |
| Short-time withstand current (Icw) for 3 s | 50 kA |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Power loss | 180 W |
| Mechanical durability | 25,000 cycles |
| Net weight | 55 kg |
| Standard | IEC |
| HS code | 85362090 |
| ABB product group | 310513-New Emax |
The ABB 1SDA056019R1 is a 2000 A three-pole fixed air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution systems.
The PR122/P-LI electronic overcurrent release provides long-time and instantaneous protection, commonly abbreviated as LI, helping protect electrical circuits against overload and severe short-circuit conditions.
The E2S2000 circuit breaker and its R2000 overcurrent release are rated at 2000 A.
The ABB 1SDA056019R1 is a fixed three-pole circuit breaker fitted with horizontal rear terminals.
The E2S2000 provides an ultimate and service short-circuit breaking capacity of 85 kA at 415 V AC and 65 kA at 690 V AC, with a short-time withstand current of 65 kA for 1 s.
ABB SACE Emax air circuit breakers are engineered for dependable low-voltage power distribution, combining high-current switching capability, electronic protection and robust short-circuit performance for industrial, commercial and infrastructure electrical systems.
We use cookies