1SDA056019R1 ABB E2S2000 PR122/P-LI 2000A 3-Pole Fixed Air Circuit Breaker

1SDA056019R1 ABB E2S2000 PR122/P-LI 2000A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA056019R1 E2S2000 PR122/P-LI is a 2000 A three-pole fixed SACE Emax air circuit breaker with an R2000 LI electronic overcurrent release, 85 kA breaking capacity at 415 V AC and horizontal rear terminals for demanding low-voltage power distribution systems.

SKU: 1SDA056019R1MPN: 1SDA056019R1
Price
List Price £14,883.45 ex VAT
Your Price (ex VAT) Save 25%
£11,162.59 25% OFF
You save £3,720.86 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,162.59
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,162.59

Why Choose the ABB E2S2000 PR122/P-LI 2000A Air Circuit Breaker?

The ABB E2S2000 PR122/P-LI, order code 1SDA056019R1, is a high-performance three-pole fixed air circuit breaker (ACB) designed for switching and protection in demanding low-voltage electrical distribution systems. Part of the established ABB SACE Emax series, this E2S circuit breaker combines a rated current of 2000 A with the PR122/P electronic overcurrent release for dependable protection in industrial, commercial and infrastructure power networks.

This configuration is supplied as a fixed three-pole circuit breaker with horizontal rear terminals. The fitted PR122/P-LI R2000 electronic overcurrent release provides long-time and instantaneous protection functions, helping protect electrical systems against sustained overloads and severe short-circuit faults while providing a robust solution for high-current switchboard applications.

The E2S performance level provides an ultimate and service short-circuit breaking capacity of 85 kA at 415 V AC and 65 kA at 690 V AC, together with a short-time withstand current of 65 kA for 1 s. Four auxiliary contacts and open/closed circuit-breaker position indication support status signalling, monitoring and integration into low-voltage power distribution assemblies.

Key Advantages

  • High-performance ABB SACE Emax E2S air circuit breaker for demanding low-voltage power distribution.
  • 2000 A rated current for high-current industrial and commercial installations.
  • Three-pole fixed configuration for three-phase electrical distribution systems.
  • PR122/P-LI electronic overcurrent release for dependable circuit protection.
  • Long-time and instantaneous protection against overload and severe short-circuit conditions.
  • 85 kA ultimate and service short-circuit breaking capacity at 415 V AC.
  • 65 kA short-time withstand current for 1 s for robust fault-current performance.
  • Horizontal rear terminals support efficient integration into switchboards and power distribution assemblies.

Key Features

  • ABB SACE Emax E2S series.
  • 2000 A rated uninterrupted current.
  • Three-pole construction.
  • Fixed installation version.
  • Horizontal rear terminals (HR).
  • PR122/P electronic overcurrent release.
  • R2000 release rating.
  • LI protection: long-time and instantaneous.
  • 690 V AC rated operational voltage.
  • 85 kA breaking capacity at 415 V AC.
  • 65 kA breaking capacity at 690 V AC.
  • Four auxiliary contacts plus open/closed position indication.

Advanced Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax E2S2000 provide switching, isolation and protection for high-current low-voltage distribution circuits. The E2S performance class combines high short-circuit interruption capability with robust short-time withstand performance, making this breaker suitable for main distribution boards, incomers, feeders and other critical positions where substantial prospective fault currents may be present.

The PR122/P electronic overcurrent release provides LI protection for demanding electrical networks. Long-time protection responds to sustained overload conditions, while instantaneous protection rapidly interrupts severe short-circuit currents to help safeguard conductors, switchgear, transformers and connected electrical equipment.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incomer and high-current feeder protection.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure installations.
  • Motor control centres and power distribution assemblies.
  • Transformer secondary and generator distribution circuits.
  • High fault-level low-voltage switchgear systems.

Technical Specifications

Series SACE Emax
ABB order code 1SDA056019R1
EAN 8015644573591
Product type Air circuit breaker (ACB)
Frame / performance level E2S
Short-circuit performance level S
Rated current (In) 2000 A
Rated operational current (Ie) 2000 A
Rated uninterrupted current (Iu) 2000 A
Number of poles 3
Current type AC
Installation version Fixed
Terminal configuration Horizontal rear terminals
Trip unit PR122/P
Overcurrent release rating R2000
Release type Electronic
Protection functions LI
Long-time protection L
Instantaneous protection I
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 65 kA
Service short-circuit breaking capacity (Ics) at 500 V AC 65 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 65 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 65 kA
Short-time withstand current (Icw) for 1 s 65 kA
Short-time withstand current (Icw) for 3 s 50 kA
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Power loss 180 W
Mechanical durability 25,000 cycles
Net weight 55 kg
Standard IEC
HS code 85362090
ABB product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA056019R1 used for?

The ABB 1SDA056019R1 is a 2000 A three-pole fixed air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution systems.

What protection functions does the PR122/P-LI trip unit provide?

The PR122/P-LI electronic overcurrent release provides long-time and instantaneous protection, commonly abbreviated as LI, helping protect electrical circuits against overload and severe short-circuit conditions.

What is the rated current of the ABB E2S2000 PR122/P-LI?

The E2S2000 circuit breaker and its R2000 overcurrent release are rated at 2000 A.

Is the ABB 1SDA056019R1 fixed or withdrawable?

The ABB 1SDA056019R1 is a fixed three-pole circuit breaker fitted with horizontal rear terminals.

What is the breaking capacity of the ABB E2S2000?

The E2S2000 provides an ultimate and service short-circuit breaking capacity of 85 kA at 415 V AC and 65 kA at 690 V AC, with a short-time withstand current of 65 kA for 1 s.

Trusted Protection for Critical Power Systems

ABB SACE Emax air circuit breakers are engineered for dependable low-voltage power distribution, combining high-current switching capability, electronic protection and robust short-circuit performance for industrial, commercial and infrastructure electrical systems.