1SDA056001R1 ABB E2S1600 PR121/P-LSI 1600A 3-Pole Withdrawable Air Circuit Breaker

1SDA056001R1 ABB E2S1600 PR121/P-LSI 1600A 3-Pole Withdrawable Air Circuit Breaker

ABB 1SDA056001R1 E2S1600 PR121/P-LSI is a 1600 A three-pole withdrawable SACE Emax air circuit breaker moving part with an R1600 LSI electronic overcurrent release and 85 kA breaking capacity at 415 V AC for demanding low-voltage power distribution systems.

SKU: 1SDA056001R1Alt SKU: E2S 1600A 3P DRAWOMPN: 1SDA056001R1
Price
List Price £12,843.69 ex VAT
Your Price (ex VAT) Save 25%
£9,632.77 25% OFF
You save £3,210.92 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,632.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,632.77

Why Choose the ABB E2S1600 PR121/P-LSI 1600A Air Circuit Breaker?

The ABB E2S1600 PR121/P-LSI, order code 1SDA056001R1, is a high-performance three-pole withdrawable air circuit breaker moving part designed for switching and protection in demanding low-voltage electrical distribution systems. Part of the established ABB SACE Emax series, this E2S circuit breaker combines a rated current of 1600 A with the PR121/P electronic overcurrent release for dependable protection in industrial, commercial and infrastructure power networks.

This configuration is supplied as the withdrawable moving part (W MP) for use with a compatible SACE Emax withdrawable fixed part. The fitted PR121/P-LSI R1600 electronic overcurrent release provides long-time, short-time and instantaneous protection functions, helping protect electrical systems against sustained overloads and short-circuit faults while supporting selective protection coordination.

The E2S performance level provides an ultimate and service short-circuit breaking capacity of 85 kA at 415 V AC and 65 kA at 690 V AC, together with a short-time withstand current of 65 kA for 1 s. The breaker is fitted with four auxiliary contacts and open/closed position indication, supporting status signalling and integration into maintainable high-current switchboards.

Key Advantages

  • High-performance ABB SACE Emax E2S air circuit breaker moving part for low-voltage power distribution.
  • 1600 A rated current for demanding industrial and commercial distribution applications.
  • Three-pole withdrawable configuration for three-phase electrical systems.
  • PR121/P-LSI electronic overcurrent release for accurate circuit protection.
  • Long-time, short-time and instantaneous protection against overload and short-circuit conditions.
  • 85 kA ultimate and service short-circuit breaking capacity at 415 V AC.
  • 65 kA short-time withstand current for 1 s for robust fault-current performance.
  • Withdrawable moving-part architecture supports efficient inspection, servicing and replacement.

Key Features

  • ABB SACE Emax E2S series.
  • 1600 A rated uninterrupted current.
  • Three-pole construction.
  • Withdrawable moving part (W MP).
  • PR121/P electronic overcurrent release.
  • R1600 release rating.
  • LSI protection: long-time, short-time and instantaneous.
  • 690 V AC rated operational voltage.
  • 85 kA breaking capacity at 415 V AC.
  • 65 kA breaking capacity at 690 V AC.
  • Four auxiliary contacts for status signalling.
  • Open/closed circuit-breaker position indication.

Advanced Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax E2S1600 provide switching, isolation and protection for high-current low-voltage distribution circuits. The E2S performance class combines high short-circuit interruption capability with robust short-time withstand performance, while the withdrawable architecture enables the moving circuit-breaker assembly to be removed from its compatible fixed part for inspection, servicing or replacement.

The PR121/P electronic overcurrent release provides LSI protection for demanding electrical networks. Long-time protection responds to sustained overload conditions, short-time protection supports selective coordination during fault events, and instantaneous protection rapidly interrupts severe short-circuit currents to help safeguard conductors, switchgear and connected electrical equipment.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incomer and high-current feeder protection.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure installations.
  • Motor control centres and power distribution assemblies.
  • Transformer secondary and generator distribution circuits.
  • Switchgear requiring withdrawable circuit-breaker architecture for maintenance flexibility.

Technical Specifications

Series SACE Emax
ABB order code 1SDA056001R1
EAN 8015644573416
Product type Air circuit breaker moving part
Frame / performance level E2S
Short-circuit performance level S
Rated current (In) 1600 A
Rated operational current (Ie) 1600 A
Rated uninterrupted current (Iu) 1600 A
Number of poles 3
Current type AC
Installation version Withdrawable
Configuration Moving part (MP)
Trip unit PR121/P
Overcurrent release rating R1600
Release type Electronic
Protection functions LSI
Long-time protection L
Short-time protection S
Instantaneous protection I
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 65 kA
Service short-circuit breaking capacity (Ics) at 500 V AC 65 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 65 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 65 kA
Short-time withstand current (Icw) for 1 s 65 kA
Short-time withstand current (Icw) for 3 s 50 kA
Terminal connection type Withdrawable circuit breaker
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Power loss 215 W
Mechanical durability 25,000 cycles
Electrical durability at ≤440 V 12,000 cycles
Electrical durability at 500–690 V 10,000 cycles
Dimensions (W × H × D) 324 × 461 × 396.5 mm
Net weight 49 kg
Standard IEC
HS code 85362090
ABB product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA056001R1 used for?

The ABB 1SDA056001R1 is a 1600 A three-pole withdrawable air circuit breaker moving part designed for switching and protecting high-current low-voltage electrical distribution systems.

What protection functions does the PR121/P-LSI trip unit provide?

The PR121/P-LSI electronic overcurrent release provides long-time, short-time and instantaneous protection, commonly abbreviated as LSI, for protection against overload and short-circuit conditions.

What is the rated current of the ABB E2S1600 PR121/P-LSI?

The E2S1600 circuit breaker and its R1600 overcurrent release are rated at 1600 A.

Is the ABB 1SDA056001R1 fixed or withdrawable?

The ABB 1SDA056001R1 is the withdrawable moving part of the E2S1600 circuit breaker and is designed for use with the corresponding SACE Emax withdrawable fixed part.

What is the breaking capacity of the ABB E2S1600?

The E2S1600 provides an ultimate and service short-circuit breaking capacity of 85 kA at 415 V AC and 65 kA at 690 V AC, with a short-time withstand current of 65 kA for 1 s.

Trusted Protection for Critical Power Systems

ABB SACE Emax air circuit breakers are engineered for dependable low-voltage power distribution, combining high-current switching capability, electronic protection and maintainable withdrawable configurations for industrial, commercial and infrastructure electrical systems.