ABB 1SDA055986R1 E2S1600 PR121/P-LSIG is a 1600 A three-pole fixed SACE Emax air circuit breaker with an R1600 LSIG electronic overcurrent release, 85 kA breaking capacity at 415 V AC and horizontal rear terminals for demanding low-voltage power distribution systems.

SKU: 1SDA055986R1MPN: 1SDA055986R1
Price
List Price £12,734.51 ex VAT
Your Price (ex VAT) Save 25%
£9,550.88 25% OFF
You save £3,183.63 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,550.88
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,550.88

Why Choose the ABB E2S1600 PR121/P-LSIG 1600A Air Circuit Breaker?

The ABB E2S1600 PR121/P-LSIG, order code 1SDA055986R1, is a high-performance three-pole fixed air circuit breaker (ACB) designed for switching and protection in demanding low-voltage electrical distribution systems. Part of the established ABB SACE Emax series, this E2S circuit breaker combines a rated current of 1600 A with the PR121/P electronic overcurrent release for dependable protection in industrial, commercial and infrastructure power networks.

This configuration is supplied as a fixed three-pole circuit breaker with horizontal rear terminals and an R1600 PR121/P-LSIG electronic overcurrent release. The LSIG trip unit provides long-time, short-time, instantaneous and ground-fault protection functions, helping protect electrical systems against sustained overloads, short circuits and earth faults while supporting coordinated protection throughout the distribution network.

The E2S performance level provides an ultimate and service short-circuit breaking capacity of 85 kA at 415 V AC and 65 kA at 690 V AC, together with a short-time withstand current of 65 kA for 1 s. Four auxiliary contacts and open/closed position indication support remote status signalling, monitoring and integration into high-current low-voltage switchboards.

Key Advantages

  • High-performance ABB SACE Emax E2S air circuit breaker for demanding low-voltage power distribution.
  • 1600 A rated current for high-current industrial and commercial installations.
  • Three-pole fixed configuration for three-phase electrical distribution systems.
  • PR121/P-LSIG electronic overcurrent release for comprehensive circuit protection.
  • Long-time, short-time, instantaneous and ground-fault protection against multiple electrical fault conditions.
  • 85 kA ultimate and service short-circuit breaking capacity at 415 V AC.
  • 65 kA short-time withstand current for 1 s for robust fault-current performance.
  • Horizontal rear terminals support efficient integration into switchboards and power distribution assemblies.

Key Features

  • ABB SACE Emax E2S series.
  • 1600 A rated uninterrupted current.
  • Three-pole construction.
  • Fixed installation version.
  • Horizontal rear terminals (HR).
  • PR121/P electronic overcurrent release.
  • R1600 release rating.
  • LSIG protection: long-time, short-time, instantaneous and ground-fault.
  • 690 V AC rated operational voltage.
  • 85 kA breaking capacity at 415 V AC.
  • 65 kA breaking capacity at 690 V AC.
  • Four auxiliary contacts plus open/closed position indication.

Advanced Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax E2S1600 provide switching, isolation and protection for high-current low-voltage distribution circuits. The E2S performance class combines high short-circuit interruption capability with robust short-time withstand performance, making this breaker suitable for main distribution boards, incomers, feeders and other critical positions where substantial prospective fault currents may be present.

The PR121/P electronic overcurrent release provides comprehensive LSIG protection for demanding electrical networks. Long-time protection responds to sustained overloads, short-time protection supports selective coordination during fault events, instantaneous protection rapidly interrupts severe short circuits, and ground-fault protection detects potentially damaging earth-fault currents within the distribution system.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incomer and high-current feeder protection.
  • Manufacturing and process plants.
  • Commercial buildings and infrastructure installations.
  • Motor control centres and power distribution assemblies.
  • Transformer secondary and generator distribution circuits.
  • High fault-level systems requiring integrated ground-fault protection.

Technical Specifications

Series SACE Emax
ABB order code 1SDA055986R1
EAN 8015644573263
Product type Air circuit breaker (ACB)
Frame / performance level E2S
Short-circuit performance level S
Rated current (In) 1600 A
Rated operational current (Ie) 1600 A
Rated uninterrupted current (Iu) 1600 A
Number of poles 3
Current type AC
Installation version Fixed
Terminal configuration Horizontal rear terminals
Trip unit PR121/P
Overcurrent release rating R1600
Release type Electronic
Protection functions LSIG
Long-time protection L
Short-time protection S
Instantaneous protection I
Ground-fault protection G
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 65 kA
Service short-circuit breaking capacity (Ics) at 500 V AC 65 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 65 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 65 kA
Short-time withstand current (Icw) for 1 s 65 kA
Short-time withstand current (Icw) for 3 s 50 kA
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Power loss 115 W
Mechanical durability 25,000 cycles
Electrical durability at ≤440 V 12,000 cycles
Electrical durability at 500–690 V 10,000 cycles
Net weight 55 kg
Standard IEC
HS code 85362090
ABB product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA055986R1 used for?

The ABB 1SDA055986R1 is a 1600 A three-pole fixed air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution systems.

What protection functions does the PR121/P-LSIG trip unit provide?

The PR121/P-LSIG electronic overcurrent release provides long-time, short-time, instantaneous and ground-fault protection, commonly abbreviated as LSIG, covering overload, short-circuit and earth-fault conditions.

What is the rated current of the ABB E2S1600 PR121/P-LSIG?

The E2S1600 circuit breaker and its R1600 overcurrent release are rated at 1600 A.

Is the ABB 1SDA055986R1 fixed or withdrawable?

The ABB 1SDA055986R1 is a fixed three-pole circuit breaker fitted with horizontal rear terminals.

What is the breaking capacity of the ABB E2S1600?

The E2S1600 provides an ultimate and service short-circuit breaking capacity of 85 kA at 415 V AC and 65 kA at 690 V AC, with a short-time withstand current of 65 kA for 1 s.

Trusted Protection for Critical Power Systems

ABB SACE Emax air circuit breakers are engineered for dependable low-voltage power distribution, combining high-current switching capability, comprehensive electronic LSIG protection and robust short-circuit performance for industrial, commercial and infrastructure electrical systems.