Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA055984R1 is a SACE Emax E2S 1600 A three-pole fixed air circuit breaker with rear horizontal terminals and a PR121/P-LI R1600 electronic overcurrent release for high-current low-voltage power distribution protection.
£8,107.52
The ABB 1SDA055984R1 is a high-performance SACE Emax E2S 1600 air circuit breaker (ACB) designed for reliable switching, isolation and protection in demanding low-voltage electrical distribution systems. Part of the ABB SACE Emax E2 series, this three-pole fixed circuit breaker is equipped with a PR121/P-LI R1600 electronic overcurrent release for dependable circuit protection.
With a rated uninterrupted current of 1600 A and a rated operational voltage of up to 690 V AC, the E2S 1600 is suitable for industrial switchboards, commercial power distribution, transformer protection and other high-current applications. The PR121/P-LI electronic trip unit provides long-time overload and instantaneous short-circuit protection, helping protect conductors and connected equipment against damaging overcurrent conditions.
The E2S performance level provides a rated ultimate short-circuit breaking capacity of 85 kA at 400–415 V AC and 65 kA at 500–690 V AC. This version is supplied as a three-pole fixed circuit breaker with rear horizontal terminals and includes four auxiliary contacts with open/closed position indication for integration into low-voltage switchgear.
Air circuit breakers such as the ABB SACE Emax E2S provide switching, isolation and fault protection for high-current low-voltage distribution circuits. The E2S 1600 combines a substantial continuous-current rating with high short-circuit breaking performance, making it particularly suitable for main switchboards and industrial distribution systems where dependable interruption of significant fault currents is essential.
The PR121/P-LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. Combined with the fixed SACE Emax construction and rear horizontal terminals, the 1SDA055984R1 provides a robust solution for permanent switchgear installations requiring reliable electronic overcurrent protection and high breaking capacity.
| Product family | SACE Emax |
|---|---|
| Series | E2S |
| ABB order code | 1SDA055984R1 |
| Product group | 310513-New Emax |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated operational current (Ie) | 1600 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 3 |
| Execution | Fixed |
| Terminal arrangement | Rear horizontal terminals |
| Trip unit | PR121/P-LI R1600 |
| Release type | Electronic |
| Protection functions | LI – long-time overload and instantaneous short-circuit protection |
| Short-circuit performance level | S |
| Rated ultimate short-circuit breaking capacity (Icu) at 220–440 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC | 65 kA |
| Rated service short-circuit breaking capacity (Ics) at 220–440 V AC | 85 kA |
| Rated service short-circuit breaking capacity (Ics) at 500–690 V AC | 65 kA |
| Rated short-time withstand current (Icw), 1 s | 65 kA |
| Rated short-time withstand current (Icw), 3 s | 50 kA |
| Current type | AC |
| Power loss | 115 W |
| Electrical durability at ≤440 V | 12000 cycles |
| Electrical durability at 500–690 V | 10000 cycles |
| Mechanical durability | 25000 cycles |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Weight | 55 kg |
| EAN | 8015644573249 |
The ABB 1SDA055984R1 is a 1600 A three-pole air circuit breaker designed for switching, isolation and overcurrent protection in demanding low-voltage electrical distribution systems.
The circuit breaker has a rated uninterrupted current of 1600 A and a rated operational voltage of up to 690 V AC.
The PR121/P-LI electronic trip unit provides LI protection functions consisting of long-time overload protection and instantaneous short-circuit protection.
The E2S 1600 provides a rated ultimate short-circuit breaking capacity of 85 kA at 400–415 V AC and 65 kA at 500–690 V AC.
The ABB 1SDA055984R1 is a three-pole fixed air circuit breaker with rear horizontal terminals for permanent installation within compatible low-voltage switchgear.
ABB SACE Emax air circuit breakers are engineered to provide dependable switching, isolation and electronic protection in demanding low-voltage power distribution systems, making the E2S 1600 a robust solution for industrial, commercial and infrastructure installations.