1SDA055951R1 ABB E2N2000 PR123/P-LSIG 2000A 4-Pole Withdrawable Air Circuit Breaker Moving Part

1SDA055951R1 ABB E2N2000 PR123/P-LSIG 2000A 4-Pole Withdrawable Air Circuit Breaker Moving Part

ABB 1SDA055951R1 E2N2000 is a 2000 A four-pole withdrawable SACE Emax air circuit breaker moving part with PR123/P-LSIG electronic protection, integrated ground-fault protection and 65 kA breaking capacity at 400 V AC.

SKU: 1SDA055951R1MPN: 1SDA055951R1
Price
List Price £29,572.90 ex VAT
Your Price (ex VAT) Save 25%
£22,179.68 25% OFF
You save £7,393.23 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £22,179.68
Trade pricing is personalised to your account

Manufacturer Lead Time

£22,179.68

Why Choose the ABB E2N2000 PR123/P-LSIG 2000A 4-Pole Withdrawable Air Circuit Breaker?

The ABB 1SDA055951R1 is a high-performance SACE Emax E2N air circuit breaker (ACB) moving part designed for switching and protection in demanding low-voltage electrical distribution systems. Rated at 2000 A, this four-pole withdrawable circuit breaker moving part is equipped with the PR123/P-LSIG R2000 electronic overcurrent release for comprehensive protection against overload, short-circuit and ground-fault conditions.

As part of the ABB SACE Emax / New Emax range, the E2N2000 combines high short-circuit performance with advanced electronic protection for industrial and commercial power distribution. The PR123/P-LSIG release provides long-time, short-time, instantaneous and ground-fault protection functions, supporting selective coordination while protecting cables, busbars, transformers and connected electrical equipment.

The E2N2000 PR123/P-LSIG is a four-pole withdrawable moving part with a rated uninterrupted current of 2000 A and a rated voltage of 690 V AC. Its E2N performance level provides a rated ultimate short-circuit breaking capacity of 65 kA at 400 V AC, while the draw-out construction enables the breaker moving part to be removed from its corresponding fixed part for inspection, maintenance or replacement.

Key Advantages

  • High-capacity 2000 A SACE Emax air circuit breaker moving part.
  • Four-pole configuration for three-phase four-wire electrical distribution systems.
  • Advanced PR123/P-LSIG R2000 electronic overcurrent release.
  • LSIG protection provides long-time, short-time, instantaneous and ground-fault protection.
  • 65 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Adjustable overload protection from 800–2000 A.
  • Withdrawable moving-part construction supports serviceable and maintainable switchgear installations.
  • Four auxiliary change-over contacts with circuit-breaker open/closed position indication.

Key Features

  • ABB SACE Emax E2N2000 air circuit breaker moving part.
  • 2000 A rated uninterrupted current.
  • Four-pole configuration.
  • Withdrawable / draw-out construction.
  • Moving part (MP) for use with the corresponding fixed part.
  • PR123/P-LSIG R2000 electronic overcurrent release.
  • Long-time, short-time, instantaneous and ground-fault LSIG protection functions.
  • 690 V AC rated voltage.
  • 65 kA Icu at 400 V AC, 50 Hz.
  • IP2X degree of protection.
  • Four auxiliary change-over contacts.
  • Optional motor operating mechanism for electrically operated applications.

Advanced LSIG Protection for High-Current Draw-Out Distribution

Air circuit breakers such as the ABB E2N2000 provide switching, isolation and protection for high-current low-voltage distribution circuits. The four-pole configuration is particularly suitable for three-phase four-wire systems, while the withdrawable architecture allows the breaker moving part to be disconnected and removed from its corresponding fixed part for inspection, servicing or replacement without permanently disturbing the switchboard's main connections.

The PR123/P-LSIG electronic release provides long-time protection against sustained overloads, short-time protection for selective short-circuit coordination, instantaneous protection against severe fault currents and integrated ground-fault protection. Combined with the E2N's 65 kA breaking capacity at 400 V AC, these functions support comprehensive protection and coordination in demanding industrial and commercial electrical distribution networks.

Typical Applications

  • Industrial low-voltage switchboards and distribution panels.
  • Three-phase four-wire high-current electrical distribution systems.
  • Main incoming circuit protection.
  • High-fault-level feeder protection.
  • Withdrawable and draw-out switchgear assemblies.
  • Busbar and bus-coupler applications.
  • Transformer secondary and generator distribution systems.
  • Manufacturing, process, commercial and infrastructure installations.

Technical Specifications

Series SACE Emax / New Emax
ABB order code 1SDA055951R1
Product group 310513-New Emax
Product type Air circuit breaker moving part
Frame E2N
Rated current (In) 2000 A
Rated uninterrupted current (Iu) 2000 A
Rated voltage 690 V AC
Number of poles 4
Current type AC
Installation Withdrawable / draw-out
Configuration Moving part (MP)
Trip unit PR123/P-LSIG R2000
Release type Electronic overcurrent release
Protection functions Long-time, short-time, instantaneous and ground fault (LSIG)
Overload release adjustment 800–2000 A
Short-time short-circuit release adjustment 1200–20000 A
Instantaneous short-circuit release adjustment 3000–30000 A
Ground-fault protection Integrated
Short-circuit performance level N
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 65 kA
Protection rating IP2X
Auxiliary contacts 4 change-over contacts
Position indication Open / closed
Trip indication Yes
Motor drive integrated No
Motor operating mechanism Optional
DIN rail mounting No
Weight 73 kg
EAN 8015644572914

Frequently Asked Questions

What is the ABB 1SDA055951R1 used for?

The ABB 1SDA055951R1 is a 2000 A four-pole withdrawable SACE Emax air circuit breaker moving part used for switching and protecting high-current low-voltage electrical distribution circuits.

What current rating does the ABB E2N2000 1SDA055951R1 have?

The circuit breaker moving part has a rated uninterrupted current of 2000 A.

What protection unit is fitted to the ABB 1SDA055951R1?

The breaker is fitted with an ABB PR123/P-LSIG R2000 electronic overcurrent release, providing long-time, short-time, instantaneous and integrated ground-fault protection.

What is the breaking capacity of the ABB E2N2000?

The E2N2000 has a rated ultimate short-circuit breaking capacity of 65 kA at 400 V AC, 50 Hz.

Is the ABB 1SDA055951R1 fixed or withdrawable?

The 1SDA055951R1 is a four-pole withdrawable moving part designed for use with the corresponding ABB SACE Emax fixed part to form a complete draw-out air circuit breaker assembly.