1SDA055945R1 ABB E2N2000 2000 A 4-Pole Withdrawable Air Circuit Breaker

1SDA055945R1 ABB E2N2000 2000 A 4-Pole Withdrawable Air Circuit Breaker

ABB E2N2000 1SDA055945R1 is a 2000 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR121/P-LSI electronic trip unit for high-current low-voltage distribution protection.

SKU: 1SDA055945R1Alt SKU: E2NMPN: 1SDA055945R1
Price
List Price £21,003.20 ex VAT
Your Price (ex VAT) Save 25%
£15,752.40 25% OFF
You save £5,250.80 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £15,752.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£15,752.40

Why Choose the ABB E2N2000 1SDA055945R1 Air Circuit Breaker?

The ABB E2N2000 1SDA055945R1 is a high-performance SACE Emax air circuit breaker (ACB) moving part designed for protection and switching in high-current low-voltage electrical distribution systems. Part of the proven ABB SACE Emax E2 series, this four-pole withdrawable breaker combines a 2000 A rated current with the electronic PR121/P-LSI trip unit for dependable overload, short-time and instantaneous short-circuit protection.

Designed for demanding industrial and commercial power distribution applications, the E2N2000 provides reliable circuit protection while its withdrawable construction supports convenient inspection and maintenance when installed with the appropriate Emax fixed part. The PR121/P-LSI electronic release provides L, S and I protection functions, enabling effective coordination against overload and short-circuit conditions.

This model is a four-pole withdrawable moving part rated for operation up to 690 V AC. The E2N performance level provides a rated ultimate short-circuit breaking capacity of 65 kA at 415 V AC, making the breaker suitable for substantial industrial distribution systems where high fault-current interruption capability is required.

Key Advantages

  • High-current 2000 A air circuit breaker moving part for low-voltage power distribution.
  • PR121/P-LSI electronic trip unit provides long-time, short-time and instantaneous protection.
  • 65 kA breaking capacity at 415 V AC for demanding fault conditions.
  • Four-pole withdrawable configuration supports maintainable switchboard installations.
  • Rated operational voltage up to 690 V AC.
  • Equipped with auxiliary contacts and circuit-breaker open/closed position indication.

Key Features

  • ABB SACE Emax E2N2000 air circuit breaker.
  • 2000 A rated current.
  • 4-pole configuration.
  • PR121/P-LSI electronic release.
  • LSI protection functions: long-time, short-time and instantaneous.
  • Withdrawable moving part (W MP) execution.
  • 65 kA Icu at 415 V AC.
  • 55 kA Icu at 690 V AC.
  • 55 kA Icw for 1 second.
  • Rated insulation voltage of 1000 V.
  • Four auxiliary contacts for circuit-breaker open/closed status.

Reliable Protection for High-Current Distribution Systems

Air circuit breakers such as the ABB E2N2000 provide switching and protection at the main and distribution levels of low-voltage electrical installations. Their high current ratings and substantial short-circuit interruption capability make them particularly suitable for switchboards supplying industrial machinery, infrastructure and large commercial loads.

The PR121/P-LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Combined with the withdrawable Emax platform, this provides dependable electrical protection together with convenient breaker removal for servicing and maintenance when used with the compatible fixed part.

Typical Applications

  • Main low-voltage switchboards and distribution boards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical installations.
  • Transformer secondary and feeder protection.
  • High-current machinery and production systems.

Technical Specifications

Series SACE Emax E2
ABB order code 1SDA055945R1
Product type Air circuit breaker moving part
Rated current (In) 2000 A
Rated uninterrupted current (Iu) 2000 A
Rated operational current (Ie) 2000 A
Number of poles 4
Execution Withdrawable moving part
Trip unit PR121/P-LSI electronic release
Protection functions L, S, I
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated ultimate breaking capacity (Icu) at 415 V AC 65 kA
Rated service breaking capacity (Ics) at 415 V AC 65 kA
Rated ultimate breaking capacity (Icu) at 690 V AC 55 kA
Rated service breaking capacity (Ics) at 690 V AC 55 kA
Rated short-time withstand current (Icw), 1 s 55 kA
Rated short-time withstand current (Icw), 3 s 42 kA
Short-circuit performance level N
Current type AC
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Standard IEC

Frequently Asked Questions

What is the ABB E2N2000 1SDA055945R1 used for?

It is a 2000 A air circuit breaker moving part designed for switching and protection of high-current low-voltage electrical distribution systems.

What trip unit is fitted to the ABB 1SDA055945R1?

This circuit breaker is equipped with an ABB PR121/P-LSI electronic trip unit providing long-time, short-time and instantaneous protection functions.

What is the rated current of this circuit breaker?

The ABB E2N2000 1SDA055945R1 has a rated current of 2000 A.

What is the breaking capacity of the E2N2000?

The E2N2000 has a rated ultimate short-circuit breaking capacity of 65 kA at 415 V AC and 55 kA at 690 V AC.

Is the ABB 1SDA055945R1 fixed or withdrawable?

This model is a four-pole withdrawable moving part designed for use with the corresponding SACE Emax E2 fixed part.

Trusted ABB Power Distribution Technology

ABB SACE Emax air circuit breakers are engineered for dependable protection and control of low-voltage power distribution systems, combining high breaking performance, electronic protection and maintainable withdrawable construction for demanding industrial and commercial installations.