1SDA055928R1 ABB E2N 2000 PR121/P-LI 2000 A 4-Pole Fixed Air Circuit Breaker

1SDA055928R1 ABB E2N 2000 PR121/P-LI 2000 A 4-Pole Fixed Air Circuit Breaker

ABB 1SDA055928R1 is a SACE Emax E2N 2000 A four-pole fixed air circuit breaker with rear horizontal terminals and a PR121/P-LI electronic overcurrent release for high-current low-voltage power distribution protection.

SKU: 1SDA055928R1MPN: 1SDA055928R1
Price
List Price £17,859.73 ex VAT
Your Price (ex VAT) Save 25%
£13,394.80 25% OFF
You save £4,464.93 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £13,394.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£13,394.80

Why Choose the ABB E2N 2000 PR121/P-LI 1SDA055928R1 Air Circuit Breaker?

The ABB 1SDA055928R1 is a robust SACE Emax E2N 2000 air circuit breaker (ACB) designed for reliable switching, isolation and circuit protection in demanding low-voltage electrical distribution systems. Part of the ABB SACE Emax E2 series, this four-pole fixed circuit breaker is equipped with a PR121/P-LI electronic overcurrent release for dependable overload and instantaneous short-circuit protection.

With a rated uninterrupted current of 2000 A and a rated operational voltage of up to 690 V AC, the E2N 2000 is suitable for high-current industrial and commercial distribution installations. Its N short-circuit performance level provides a rated ultimate breaking capacity of 65 kA at 400–415 V AC, supporting reliable fault interruption in demanding switchboard applications.

This version is supplied as a four-pole fixed circuit breaker with rear horizontal terminals. The breaker incorporates the PR121/P-LI R2000 electronic trip unit, four auxiliary contacts and open/closed circuit-breaker position indication, providing a practical solution for main distribution boards, transformer protection and industrial power systems.

Key Advantages

  • Heavy-duty 2000 A air circuit breaker for high-current electrical distribution.
  • Four-pole configuration suitable for three-phase systems requiring neutral switching.
  • 65 kA ultimate short-circuit breaking capacity at 400–415 V AC.
  • PR121/P-LI electronic overcurrent release for overload and instantaneous short-circuit protection.
  • Rated operational voltage of up to 690 V AC.
  • Fixed construction with rear horizontal terminals for switchboard installation.
  • Part of the proven ABB SACE Emax E2N circuit breaker platform.

Key Features

  • ABB SACE Emax E2N 2000 series.
  • 2000 A rated uninterrupted current.
  • Four-pole configuration.
  • Fixed execution.
  • Rear horizontal terminals.
  • PR121/P-LI R2000 electronic trip unit.
  • Long-time overload and instantaneous short-circuit protection.
  • 65 kA Icu at 400–415 V AC.
  • 55 kA Icu at 500–690 V AC.
  • 55 kA short-time withstand current for 1 s.
  • Four auxiliary contacts fitted.
  • Open/closed circuit-breaker position indication.

Reliable Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E2N provide switching, isolation and fault protection for high-current low-voltage distribution circuits. The E2N 2000 combines a high continuous-current capability with substantial short-circuit breaking performance, making it particularly suitable for main switchboards, industrial distribution panels and other installations where dependable interruption of high fault currents is essential.

The PR121/P-LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. Combined with the four-pole configuration, fixed construction and rear horizontal connections, the 1SDA055928R1 provides a robust solution for electrical distribution systems requiring reliable phase and neutral switching together with electronic circuit protection.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Transformer protection and distribution.
  • Generator and utility distribution systems.
  • Manufacturing and process plant switchgear.
  • Commercial building electrical infrastructure.
  • Four-pole distribution systems requiring neutral switching.

Technical Specifications

Product family SACE Emax
Series E2N
ABB order code 1SDA055928R1
Product group 310513-New Emax
Product type Air circuit breaker
Rated uninterrupted current (Iu) 2000 A
Rated operational current (Ie) 2000 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 4
Execution Fixed
Terminal arrangement Rear horizontal
Trip unit PR121/P-LI R2000
Protection functions LI – long-time overload and instantaneous short-circuit protection
Short-circuit performance level N
Rated ultimate short-circuit breaking capacity (Icu) at 220–440 V AC 65 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC 55 kA
Rated service short-circuit breaking capacity (Ics) at 220–440 V AC 65 kA
Rated service short-circuit breaking capacity (Ics) at 500–690 V AC 55 kA
Rated short-time withstand current (Icw), 1 s 55 kA
Rated short-time withstand current (Icw), 3 s 42 kA
Current type AC
Auxiliary contacts 4
Position indication Open / closed
Dimensions (W × H × D) 386 × 418 × 302 mm
Weight 56 kg
EAN 8015644572686

Frequently Asked Questions

What is the ABB 1SDA055928R1 used for?

The ABB 1SDA055928R1 is a 2000 A four-pole air circuit breaker designed for switching, isolation and protection in high-current low-voltage electrical distribution systems.

What is the current rating of the ABB E2N 2000 1SDA055928R1?

The circuit breaker has a rated uninterrupted current of 2000 A and is designed for demanding industrial and commercial power distribution applications.

What protection does the PR121/P-LI trip unit provide?

The PR121/P-LI electronic trip unit provides LI protection functions, consisting of long-time overload protection and instantaneous short-circuit protection.

What is the short-circuit breaking capacity of the E2N 2000?

The E2N 2000 provides a rated ultimate short-circuit breaking capacity of 65 kA at 400–415 V AC and 55 kA at 500–690 V AC.

Is the ABB 1SDA055928R1 fixed or withdrawable?

The ABB 1SDA055928R1 is a four-pole fixed circuit breaker with rear horizontal terminals for permanent installation within compatible low-voltage switchgear.

Trusted for Industrial Power Distribution

ABB SACE Emax air circuit breakers provide dependable switching, isolation and electronic protection for demanding low-voltage power distribution systems, making the E2N 2000 a robust solution for industrial, commercial and infrastructure installations.