1SDA055923R1 ABB E2N2000 PR122/P-LI 2000A 3-Pole Air Circuit Breaker

1SDA055923R1 ABB E2N2000 PR122/P-LI 2000A 3-Pole Air Circuit Breaker

ABB 1SDA055923R1 E2N2000 PR122/P-LI is a 2000 A three-pole fixed SACE Emax air circuit breaker with LI electronic protection, 65 kA breaking capacity at 415 V AC and horizontal rear terminals for low-voltage power distribution systems.

SKU: 1SDA055923R1MPN: 1SDA055923R1
Price
List Price £14,452.88 ex VAT
Your Price (ex VAT) Save 25%
£10,839.66 25% OFF
You save £3,613.22 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,839.66
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,839.66

Why Choose the ABB E2N2000 PR122/P-LI 2000A Air Circuit Breaker?

The ABB E2N2000 PR122/P-LI, order code 1SDA055923R1, is a high-performance three-pole fixed air circuit breaker (ACB) designed for protection and switching in low-voltage electrical distribution systems. As part of the proven ABB SACE Emax series, this E2N circuit breaker combines a 2000 A rated current with the advanced PR122/P electronic overcurrent release for dependable protection in industrial, commercial and infrastructure power installations.

This configuration is supplied as a fixed three-pole circuit breaker with horizontal rear terminals. The integrated PR122/P-LI electronic overcurrent release provides long-time and instantaneous protection functions, helping protect electrical networks against sustained overloads and high-level short-circuit faults.

With a rated current of 2000 A and an ultimate short-circuit breaking capacity of 65 kA at 415 V AC, the E2N2000 is suited to demanding high-current distribution applications. Its fixed construction, horizontal rear connections, four auxiliary contacts and open/closed position indication support robust integration into low-voltage switchboards and power distribution assemblies.

Key Advantages

  • High-performance ABB SACE Emax air circuit breaker for low-voltage power distribution.
  • 2000 A rated current for demanding industrial and commercial installations.
  • Three-pole fixed configuration for three-phase electrical distribution systems.
  • Advanced PR122/P-LI electronic overcurrent release for circuit protection.
  • Long-time and instantaneous protection against overload and short-circuit conditions.
  • 65 kA ultimate short-circuit breaking capacity at 415 V AC.
  • 55 kA short-time withstand current for 1 s for robust fault-current performance.
  • Horizontal rear terminals support efficient integration into switchboards and power distribution assemblies.

Key Features

  • ABB SACE Emax E2N series.
  • 2000 A rated current.
  • Three-pole construction.
  • Fixed version circuit breaker.
  • PR122/P-LI R2000 electronic overcurrent release.
  • LI protection: long-time and instantaneous.
  • 690 V AC rated operational voltage.
  • 65 kA ultimate and service short-circuit breaking capacity at 415 V AC.
  • 55 kA short-time withstand current for 1 s.
  • Horizontal rear terminal arrangement.
  • Four auxiliary contacts for status and control signalling.
  • Open/closed circuit-breaker position indication.

Advanced Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax E2N2000 provide switching, isolation and protection for high-current low-voltage distribution circuits. They are commonly installed as main incomers, feeders and distribution protection devices where dependable interruption of high prospective fault currents is essential.

The PR122/P electronic overcurrent release provides precise electronic protection for demanding electrical networks. In this LI configuration, long-time protection responds to sustained overload conditions while instantaneous protection rapidly responds to severe short-circuit currents, helping safeguard conductors, switchgear and connected electrical equipment.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incomer and high-current feeder protection.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical systems.
  • Motor control centres and power distribution assemblies.
  • Transformer secondary and generator distribution circuits.
  • High-current electrical switchgear installations.

Technical Specifications

Series SACE Emax
ABB order code 1SDA055923R1
EAN 8015644572631
Product type Air circuit breaker (ACB)
Frame / performance level E2N
Short-circuit performance level N
Rated current 2000 A
Rated operational current 2000 A
Rated uninterrupted current 2000 A
Number of poles 3
Current type AC
Installation version Fixed
Trip unit PR122/P
Overcurrent release rating R2000
Release type Electronic
Protection functions LI
Long-time protection L
Instantaneous protection I
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 12 kV
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 65 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 65 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 55 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 55 kA
Short-time withstand current (Icw) for 1 s 55 kA
Short-time withstand current (Icw) for 3 s 42 kA
Terminal configuration Horizontal rear terminals
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Power loss 180 W
Mechanical durability 25,000 cycles
Electrical durability at ≤440 V 10,000 cycles
Electrical durability at 500–690 V 8,000 cycles
Dimensions (W × H × D) 296 × 418 × 302 mm
Net weight 45 kg
Standard IEC
ABB product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA055923R1 used for?

The ABB 1SDA055923R1 is a 2000 A three-pole fixed air circuit breaker used for switching and protecting high-current low-voltage electrical distribution systems.

What protection functions does the PR122/P-LI trip unit provide?

The PR122/P-LI electronic overcurrent release provides long-time and instantaneous protection, commonly abbreviated as LI, for protection against overload and short-circuit conditions.

What is the rated current of this circuit breaker?

The E2N2000 PR122/P-LI has a rated current of 2000 A.

Is the ABB 1SDA055923R1 fixed or withdrawable?

This model is a fixed three-pole circuit breaker equipped with horizontal rear terminals.

What is the breaking capacity of the E2N2000 circuit breaker?

The ABB E2N2000 provides an ultimate short-circuit breaking capacity of 65 kA at 415 V AC and 55 kA at 690 V AC.

Trusted Protection for Critical Power Systems

ABB SACE Emax air circuit breakers are engineered for dependable low-voltage power distribution, combining high-current switching capability with advanced electronic protection for industrial, commercial and infrastructure electrical systems.