ABB 1SDA055919R1 E2N1600 is a 1600 A four-pole withdrawable SACE Emax air circuit breaker moving part with PR123/P-LSIG electronic protection, integrated ground-fault protection and 65 kA breaking capacity at 400 V AC.
£19,180.73
The ABB 1SDA055919R1 is a high-performance SACE Emax E2N air circuit breaker (ACB) moving part designed for switching and protection in demanding low-voltage electrical distribution systems. Rated at 1600 A, this four-pole withdrawable circuit breaker moving part is equipped with the PR123/P-LSIG R1600 electronic overcurrent release for comprehensive circuit protection.
As part of the ABB SACE Emax / New Emax range, the E2N1600 combines high short-circuit performance with advanced electronic protection for industrial and commercial power distribution. The PR123/P-LSIG release provides long-time, short-time, instantaneous and ground-fault protection functions, helping protect cables, busbars, transformers and connected electrical equipment against overloads, short circuits and earth faults.
The E2N1600 PR123/P-LSIG is a four-pole withdrawable moving part with a rated uninterrupted current of 1600 A and a rated operational voltage of 690 V AC. Its N performance level provides an ultimate and service short-circuit breaking capacity of 65 kA at 400 V AC and 55 kA at 690 V AC, while the withdrawable construction supports servicing and replacement within compatible SACE Emax switchgear assemblies.
Air circuit breakers such as the ABB E2N1600 provide switching, isolation and protection for high-current low-voltage distribution circuits. The four-pole configuration is well suited to three-phase four-wire systems, while the withdrawable architecture allows the circuit breaker moving part to be disconnected from its corresponding fixed part for inspection, servicing or replacement within appropriately designed switchgear.
The PR123/P-LSIG electronic release provides long-time protection against sustained overloads, short-time protection for selective short-circuit coordination, instantaneous protection against severe fault currents and ground-fault protection for earth-fault conditions. Combined with the E2N's high breaking capacity, these functions support comprehensive protection and coordination throughout demanding industrial and commercial electrical distribution networks.
| Series | SACE Emax / New Emax |
|---|---|
| ABB order code | 1SDA055919R1 |
| Product group | 310513-New Emax |
| Product type | Air circuit breaker moving part |
| Rated current (In) | 1600 A |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated operational current (Ie) | 1600 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 4 |
| Current type | AC |
| Installation | Withdrawable |
| Configuration | Moving part (MP) |
| Trip unit | PR123/P-LSIG R1600 |
| Release type | Electronic |
| Protection functions | Long-time, short-time, instantaneous and ground fault (LSIG) |
| Overload release adjustment | 640–1600 A |
| Instantaneous short-circuit release adjustment | 2400–24000 A |
| Ground-fault protection | Integrated |
| Short-circuit performance level | N |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 65 kA |
| Rated service short-circuit breaking capacity (Ics) at 400 V AC | 65 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 65 kA |
| Rated service short-circuit breaking capacity (Ics) at 440 V AC | 65 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 55 kA |
| Rated service short-circuit breaking capacity (Ics) at 500 V AC | 55 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 55 kA |
| Rated service short-circuit breaking capacity (Ics) at 690 V AC | 55 kA |
| Rated short-time withstand current (Icw) | 55 kA for 1 s; 42 kA for 3 s |
| Power loss | 215 W |
| Electrical durability | 12,000 cycles at ≤440 V AC; 10,000 cycles at 500–690 V AC |
| Auxiliary contacts | 4 change-over contacts |
| Position indication | Open / closed |
| Motor operating mechanism | Optional |
| Standards | IEC |
| Dimensions (W × H × D) | 414 × 461 × 396.5 mm |
| Net weight | 61 kg |
| Package gross weight | 73 kg |
| EAN | 8015644572594 |
The ABB 1SDA055919R1 is a 1600 A four-pole withdrawable SACE Emax air circuit breaker moving part used for switching and protecting high-current low-voltage electrical distribution circuits.
The circuit breaker moving part has a rated uninterrupted current of 1600 A.
The breaker is fitted with an ABB PR123/P-LSIG R1600 electronic overcurrent release, providing long-time, short-time, instantaneous and ground-fault protection.
The E2N1600 provides an ultimate and service short-circuit breaking capacity of 65 kA at 400 V AC and 55 kA at 690 V AC, with a short-time withstand current of 55 kA for 1 s.
The 1SDA055919R1 is a four-pole withdrawable moving part designed for connection through the corresponding ABB SACE Emax fixed part in a compatible switchgear assembly.
ABB SACE Emax air circuit breakers are designed for dependable switching and protection in demanding low-voltage power distribution systems, combining high short-circuit performance, advanced electronic LSIG protection and flexible withdrawable switchgear integration.