Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA055879R1 is a SACE Emax E2N 1250 A three-pole withdrawable air circuit breaker moving part with a PR123/P-LSIG electronic overcurrent release for comprehensive low-voltage power distribution protection.
£14,781.73
The ABB 1SDA055879R1 is a high-performance SACE Emax E2N 1250 withdrawable air circuit breaker moving part designed for protection and switching in demanding low-voltage power distribution systems. This three-pole unit combines a 1250 A rated current with ABB's advanced PR123/P-LSIG electronic overcurrent release, providing comprehensive protection for industrial, commercial and infrastructure electrical installations.
As part of the ABB SACE Emax circuit breaker range, the E2N 1250 is engineered for dependable protection of switchboards, distribution networks, transformers and high-current feeders. The PR123/P-LSIG release provides long-time, short-time, instantaneous and earth-fault protection functions, combining advanced electronic protection with measurement and monitoring capabilities for sophisticated low-voltage distribution systems.
This model is supplied as the moving part of a three-pole withdrawable circuit breaker with a rated uninterrupted current of 1250 A and rated operational voltage of 690 V AC. The E2N performance level provides an ultimate short-circuit breaking capacity of 65 kA at 400 V AC and 55 kA at 690 V AC, while its withdrawable construction supports convenient inspection and maintenance within suitable switchgear assemblies.
Air circuit breakers such as the ABB SACE Emax E2N provide switching, isolation and automatic overcurrent protection for high-current low-voltage distribution circuits. The electronic trip unit monitors electrical conditions and initiates breaker operation when configured protection thresholds are exceeded, helping protect switchgear, conductors and connected equipment against damaging overload, short-circuit and earth-fault currents.
The PR123/P-LSIG release gives this E2N 1250 comprehensive long-time, short-time, instantaneous and earth-fault protection for effective coordination within electrical distribution systems. Combined with its 1250 A rating, three-pole arrangement, withdrawable construction and high short-circuit performance, the breaker is well suited to critical industrial and commercial switchboard installations.
| Series | SACE Emax |
|---|---|
| ABB order code / MPN | 1SDA055879R1 |
| ABB product group | 310513-New Emax |
| Product type | Air circuit breaker moving part |
| Frame | E2N 1250 |
| Rated current (In) | 1250 A |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated operational current (Ie) | 1250 A |
| Number of poles | 3 |
| Version | Withdrawable (W) moving part |
| Trip unit | PR123/P-LSIG |
| Release type | Electronic |
| Protection functions | Long-time, short-time, instantaneous and earth-fault (LSIG) |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 65 kA |
| Service short-circuit breaking capacity (Ics) at 400 V AC | 65 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 55 kA |
| Service short-circuit breaking capacity (Ics) at 690 V AC | 55 kA |
| Short-time withstand current (Icw), 1 s | 55 kA |
| Short-time withstand current (Icw), 3 s | 42 kA |
| Short-circuit performance level | N |
| Integrated earth-fault protection | Yes |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Mechanical durability | 25,000 cycles |
| Power loss | 130 W |
| Standard | IEC |
| EAN | 8015644572198 |
| Weight | 59 kg |
The ABB 1SDA055879R1 is the moving part of a SACE Emax E2N 1250 three-pole withdrawable air circuit breaker, rated at 1250 A and equipped with a PR123/P-LSIG electronic overcurrent release.
The PR123/P-LSIG provides long-time, short-time, instantaneous and earth-fault protection, collectively identified as LSIG protection.
The E2N 1250 provides an ultimate short-circuit breaking capacity of 65 kA at 400 V AC and 55 kA at 690 V AC.
The 1SDA055879R1 is a withdrawable (W) version supplied as the moving part of the E2N 1250 circuit breaker system.
Yes. Its PR123/P-LSIG electronic release provides earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
The circuit breaker moving part has a rated uninterrupted current of 1250 A and is designed for high-current low-voltage distribution applications.
ABB SACE Emax air circuit breakers are engineered for dependable switching and protection in demanding low-voltage power distribution systems, supporting industrial, commercial and infrastructure installations where reliable high-current circuit protection is essential.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.