ABB 1SDA055850R1 E2B 2000 four-pole withdrawable air circuit breaker moving part rated at 2000 A with a PR121/P-LSIG R2000 electronic release, integrated earth-fault protection, four auxiliary contacts and 42 kA short-circuit breaking capacity.
£15,749.25
The ABB E2B 2000 PR121/P-LSIG, order code 1SDA055850R1, is a high-performance four-pole withdrawable air circuit breaker moving part designed for protection and switching in demanding low-voltage electrical distribution systems. Part of the ABB SACE Emax E2B series, it combines a 2000 A rated current with the PR121/P-LSIG R2000 electronic overcurrent release for comprehensive overload, short-circuit and earth-fault protection.
This E2B configuration is supplied as the withdrawable moving part (W MP) and is designed for use with the appropriate ABB Emax withdrawable fixed part. Its four-pole construction supports applications requiring four-pole switching, while the draw-out architecture enables the breaker moving assembly to be isolated and removed for inspection, servicing or replacement.
The E2B 2000 provides rated ultimate and service short-circuit breaking capacities of 42 kA throughout its specified 220–690 V AC range. The PR121/P-LSIG release combines long-time, short-time, instantaneous and earth-fault protection functions, while four auxiliary contacts and circuit-breaker open/closed position indication support integration with switchboard signalling, monitoring and control systems.
Air circuit breakers such as the ABB E2B 2000 provide switching and automatic protection for high-current low-voltage circuits. The electronic protection release monitors current conditions and commands the breaker to interrupt the circuit when configured thresholds are exceeded, helping protect cables, switchgear and connected equipment against overloads, short circuits and earth faults.
The PR121/P-LSIG release combines long-time overload protection with short-time selective, instantaneous short-circuit and earth-fault protection. Together with the withdrawable E2B architecture, this provides a practical solution for installations requiring comprehensive electronic protection and a breaker assembly that can be removed from its corresponding fixed part for inspection, servicing or replacement.
| Series | SACE Emax E2B |
|---|---|
| ABB order code | 1SDA055850R1 |
| Product group | 310513-New Emax |
| EAN | 8015644571900 |
| Product type | Air circuit breaker withdrawable moving part |
| Frame size | E2 |
| Short-circuit performance level | B |
| Rated current (In) | 2000 A |
| Rated uninterrupted current (Iu) | 2000 A |
| Rated operational current (Ie) | 2000 A |
| Number of poles | 4 |
| Current type | AC |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated ultimate short-circuit breaking capacity (Icu) | 42 kA at 220–690 V AC |
| Rated service short-circuit breaking capacity (Ics) | 42 kA at 220–690 V AC |
| Rated short-time withstand current (Icw) | 42 kA for 1 s; 42 kA for 3 s |
| Protection release | PR121/P-LSIG R2000 |
| Release type | Electronic overcurrent release |
| Protection functions | Long-time (L), short-time (S), instantaneous (I) and earth-fault (G) |
| Earth-fault protection | Integrated |
| Mounting version | Withdrawable / draw-out |
| Component | Moving part (W MP) |
| Terminal connection type | Withdrawable circuit breaker |
| Auxiliary contacts | 4 |
| Auxiliary indication | Circuit breaker open / closed position |
| Standard | IEC |
The ABB 1SDA055850R1 is an E2B 2000 four-pole withdrawable SACE Emax air circuit breaker moving part rated at 2000 A and equipped with a PR121/P-LSIG R2000 electronic overcurrent release.
The PR121/P-LSIG electronic release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.
The E2B 2000 B-performance platform provides rated ultimate and service short-circuit breaking capacities of 42 kA throughout its specified 220–690 V AC range, together with a rated short-time withstand current of 42 kA for 1 s and 3 s.
The 1SDA055850R1 is the withdrawable moving part of the E2B 2000 circuit breaker and is designed for use with the appropriate ABB Emax withdrawable fixed part.
Yes. Its PR121/P-LSIG R2000 electronic release includes integrated earth-fault (G) protection in addition to long-time, short-time and instantaneous overcurrent protection.
ABB SACE Emax air circuit breakers are engineered for dependable switching and protection in demanding low-voltage distribution systems, combining comprehensive electronic protection, robust fault-interruption performance and service-friendly withdrawable construction.