1SDA055816R1 ABB E2B1600 PR121/P-LI 1600A 4-Pole Withdrawable Air Circuit Breaker Moving Part

1SDA055816R1 ABB E2B1600 PR121/P-LI 1600A 4-Pole Withdrawable Air Circuit Breaker Moving Part

ABB 1SDA055816R1 E2B1600 is a 1600 A four-pole withdrawable SACE Emax air circuit breaker moving part with PR121/P-LI electronic overload and instantaneous short-circuit protection and a 42 kA breaking capacity at 400 V AC.

SKU: 1SDA055816R1MPN: 1SDA055816R1
Price
List Price £15,095.10 ex VAT
Your Price (ex VAT) Save 25%
£11,321.33 25% OFF
You save £3,773.78 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,321.33
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,321.33

Why Choose the ABB E2B1600 PR121/P-LI 1600A 4-Pole Withdrawable Air Circuit Breaker?

The ABB 1SDA055816R1 is a high-performance SACE Emax E2B air circuit breaker (ACB) moving part designed for switching and protection in high-current low-voltage electrical distribution systems. Rated at 1600 A, this four-pole withdrawable circuit breaker moving part is equipped with the PR121/P-LI R1600 electronic overcurrent release for reliable overload and instantaneous short-circuit protection.

As part of the ABB SACE Emax / New Emax range, the E2B1600 combines robust switching performance with electronic circuit protection for industrial and commercial power distribution. The PR121/P-LI release provides long-time and instantaneous protection functions, helping protect cables, busbars and connected electrical equipment against sustained overloads and high short-circuit currents.

The E2B1600 PR121/P-LI is a four-pole withdrawable moving part with a rated uninterrupted current of 1600 A and a rated operational voltage of 690 V AC. Its E2B performance level provides a rated ultimate short-circuit breaking capacity of 42 kA at 400 V AC, making it suitable for demanding four-wire low-voltage distribution systems where maintainability and operational flexibility are important.

Key Advantages

  • High-capacity 1600 A SACE Emax air circuit breaker moving part for low-voltage power distribution.
  • Four-pole configuration supports switching and protection in three-phase four-wire systems.
  • Electronic PR121/P-LI R1600 overcurrent release.
  • LI protection provides long-time overload and instantaneous short-circuit protection.
  • 42 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Withdrawable construction supports maintenance and replacement in compatible switchgear assemblies.
  • Four auxiliary contacts and circuit-breaker open/closed position indication.
  • Optional motor operating mechanism capability for electrically operated applications.

Key Features

  • ABB SACE Emax E2B1600 air circuit breaker moving part.
  • 1600 A rated uninterrupted current.
  • Four-pole configuration.
  • Withdrawable moving-part construction.
  • PR121/P-LI R1600 electronic overcurrent release.
  • Long-time and instantaneous LI protection functions.
  • 690 V AC rated operational voltage.
  • 42 kA rated ultimate short-circuit breaking capacity at 400 V AC.
  • Adjustable overload protection from 640–1600 A.
  • Adjustable instantaneous short-circuit protection from 2400–24000 A.
  • IP2X protection rating.
  • Four auxiliary contacts with open/closed position indication.

Reliable Protection for Four-Wire Power Distribution

Air circuit breakers such as the ABB E2B1600 provide switching, isolation and protection for high-current low-voltage distribution circuits. The four-pole construction is particularly useful in three-phase four-wire systems where switching of the neutral conductor is required alongside the three phase conductors, while the withdrawable architecture supports servicing and replacement within compatible switchgear.

The PR121/P-LI electronic release provides long-time protection against sustained overload conditions and instantaneous protection against severe short-circuit currents. Its adjustable protection settings allow the E2B1600 to be coordinated with other protective devices in industrial and commercial electrical distribution systems.

Typical Applications

  • Industrial low-voltage switchboards and distribution panels.
  • Three-phase four-wire electrical distribution systems.
  • Main incoming circuit protection.
  • High-current feeder protection.
  • Withdrawable switchgear assemblies.
  • Busbar and distribution applications.
  • Manufacturing and process plants.
  • Commercial, infrastructure and utility power distribution.

Technical Specifications

Series SACE Emax / New Emax
ABB order code 1SDA055816R1
Product group 310513-New Emax
Product type Air circuit breaker moving part
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Rated operational voltage 690 V AC
Number of poles 4
Current type AC
Installation Withdrawable
Configuration Moving part (MP)
Main circuit connection Through separate fixed part
Trip unit PR121/P-LI R1600
Release type Electronic
Protection functions Long-time and instantaneous (LI)
Overload release adjustment 640–1600 A
Instantaneous short-circuit release adjustment 2400–24000 A
Rated ultimate short-circuit breaking capacity at 400 V AC, 50 Hz 42 kA
Ground-fault protection No
Protection rating IP2X
Auxiliary contacts 4 (2 normally open and 2 normally closed)
Position indication Open / closed
Trip indication Yes
Operating mechanism Push-button
Motor operating mechanism Optional
EAN 8015644571566
Weight approx. 73 kg

Frequently Asked Questions

What is the ABB 1SDA055816R1 used for?

The ABB 1SDA055816R1 is a 1600 A four-pole withdrawable air circuit breaker moving part designed for switching and protecting high-current low-voltage electrical distribution circuits.

What current rating does the ABB E2B1600 1SDA055816R1 have?

The circuit breaker moving part has a rated uninterrupted current of 1600 A.

What protection unit is fitted to the ABB 1SDA055816R1?

The breaker is fitted with an ABB PR121/P-LI R1600 electronic overcurrent release, providing long-time overload and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E2B1600?

The E2B1600 has a rated ultimate short-circuit breaking capacity of 42 kA at 400 V AC, 50 Hz.

Is the ABB 1SDA055816R1 fixed or withdrawable?