1SDA055769R1 ABB E1N 1600 PR121/P-LSI 1600 A 4-Pole Fixed Air Circuit Breaker

1SDA055769R1 ABB E1N 1600 PR121/P-LSI 1600 A 4-Pole Fixed Air Circuit Breaker

ABB 1SDA055769R1 is a SACE Emax E1N 1600 A four-pole fixed air circuit breaker with horizontal rear terminals and a PR121/P-LSI R1600 electronic overcurrent release providing long-time, short-time and instantaneous protection for low-voltage power distribution systems.

SKU: 1SDA055769R1Alt SKU: E1N1600MPN: 1SDA055769R1
Price
List Price £13,842.74 ex VAT
Your Price (ex VAT) Save 25%
£10,382.06 25% OFF
You save £3,460.69 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,382.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,382.06

Why Choose the ABB 1SDA055769R1 E1N 1600 Air Circuit Breaker?

The ABB 1SDA055769R1 is a high-performance SACE Emax E1N 1600 air circuit breaker designed for dependable switching and protection in high-current low-voltage power distribution systems. Rated at 1600 A, this four-pole fixed circuit breaker incorporates a PR121/P-LSI R1600 electronic overcurrent release for long-time overload, short-time short-circuit and instantaneous short-circuit protection.

As part of the proven ABB SACE Emax range, the E1N 1600 combines robust high-current switching capability with electronic protection for demanding industrial, commercial and infrastructure installations. The PR121/P-LSI release provides LSI protection functions, supporting coordinated protection against sustained overloads and different levels of short-circuit current.

This configuration features a four-pole fixed design with horizontal rear terminals and four auxiliary contacts for circuit-breaker open/closed status indication. It is rated for operation up to 690 V AC and provides 50 kA ultimate and service short-circuit breaking capacity throughout its specified AC operating-voltage range.

Key Advantages

  • Heavy-duty 1600 A SACE Emax air circuit breaker for high-current low-voltage distribution.
  • Four-pole fixed configuration for permanent switchboard installations.
  • Electronic PR121/P-LSI R1600 overcurrent release for dependable circuit protection.
  • LSI functionality provides long-time, short-time and instantaneous protection.
  • 50 kA ultimate and service short-circuit breaking capacity across the specified AC voltage range.
  • Horizontal rear terminals facilitate integration with compatible switchboard busbar systems.
  • Four auxiliary contacts provide circuit-breaker open/closed status indication.

Key Features

  • ABB SACE Emax E1N 1600 circuit breaker platform.
  • 1600 A rated current.
  • Four-pole configuration.
  • Fixed (F) execution.
  • Horizontal rear (HR) terminal arrangement.
  • PR121/P-LSI R1600 electronic overcurrent release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • 50 kA ultimate and service short-circuit breaking capacity.
  • 50 kA for 1 s short-time withstand current.

Advanced LSI Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E1N are designed to switch and protect high-current low-voltage distribution circuits. The electronic overcurrent release continuously supervises circuit current so that the breaker can respond to abnormal conditions before sustained overloads or severe short circuits cause extensive damage to cables, busbars and connected electrical equipment.

The PR121/P-LSI R1600 release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. Combined with the 1600 A E1N platform, four-pole fixed construction, horizontal rear terminals and 50 kA short-circuit performance, this makes the ABB 1SDA055769R1 particularly suitable for main distribution and feeder applications requiring coordinated high-current protection.

Typical Applications

  • Main low-voltage switchboards and distribution boards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • Main incomer and high-current feeder protection.
  • Transformer and generator distribution systems.
  • Four-pole fixed switchgear requiring electronic LSI overcurrent protection.

Technical Specifications

Series SACE Emax
Frame E1N 1600
Order code 1SDA055769R1
EAN 8015644571092
Product type Air circuit breaker
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Rated operational current (Ie) 1600 A
Number of poles 4
Execution Fixed (F)
Terminal arrangement Rear flat horizontal (HR)
Trip unit PR121/P-LSI R1600
Release type Electronic overcurrent release
Protection functions Long-time, short-time and instantaneous (LSI)
Rated operational voltage 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) 50 kA
Service short-circuit breaking capacity (Ics) 50 kA
Short-time withstand current (Icw) 50 kA for 1 s; 36 kA for 3 s
Short-circuit performance level N
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Power loss 253 W
Electrical durability at Ue ≤ 440 V 10000 cycles
Electrical durability at Ue 500–690 V 8000 cycles
Mechanical durability 25000 cycles
Product net width 386 mm
Product net height 418 mm
Product net depth 302 mm
Product net weight 50 kg
Current type AC
Standard IEC
ABB product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA055769R1?

The ABB 1SDA055769R1 is a SACE Emax E1N 1600 four-pole fixed air circuit breaker rated at 1600 A and equipped with a PR121/P-LSI R1600 electronic overcurrent release.

What is the current rating of the ABB 1SDA055769R1?

The ABB 1SDA055769R1 has a rated current of 1600 A.

What protection functions does the PR121/P-LSI trip unit provide?

The PR121/P-LSI electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

How many poles does the ABB 1SDA055769R1 have?

The ABB 1SDA055769R1 has a four-pole configuration for low-voltage power distribution applications.

Is the ABB 1SDA055769R1 fixed or withdrawable?

The ABB 1SDA055769R1 is a fixed (F) air circuit breaker with rear flat horizontal terminals for permanent installation within compatible low-voltage switchgear.

What is the breaking capacity of the ABB 1SDA055769R1?

The ABB 1SDA055769R1 has an ultimate and service short-circuit breaking capacity of 50 kA throughout its specified AC operating-voltage range up to 690 V AC.

What are the dimensions of the ABB 1SDA055769R1?

The ABB 1SDA055769R1 measures approximately 386 mm wide, 418 mm high and 302 mm deep, with a net weight of approximately 50 kg.

Trusted by Electrical Engineers Worldwide

ABB SACE Emax air circuit breakers are engineered for reliable switching and protection in demanding low-voltage power distribution systems, combining robust construction, electronic overcurrent protection and high short-circuit performance for industrial, commercial and infrastructure applications.