1SDA055736R1 ABB E1N 1250 PR121/P-LI 1250 A 4-Pole Fixed Air Circuit Breaker

1SDA055736R1 ABB E1N 1250 PR121/P-LI 1250 A 4-Pole Fixed Air Circuit Breaker

ABB 1SDA055736R1 is a SACE Emax E1N 1250 A four-pole fixed air circuit breaker with horizontal rear terminals and a PR121/P-LI R1250 electronic overcurrent release providing long-time and instantaneous protection for low-voltage power distribution systems.

SKU: 1SDA055736R1MPN: 1SDA055736R1
Price
List Price £12,814.93 ex VAT
Your Price (ex VAT) Save 25%
£9,611.20 25% OFF
You save £3,203.73 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,611.20
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,611.20

Why Choose the ABB 1SDA055736R1 E1N 1250 Air Circuit Breaker?

The ABB 1SDA055736R1 is a high-performance SACE Emax E1N 1250 air circuit breaker designed for dependable switching and protection in low-voltage power distribution systems. Rated at 1250 A, this four-pole fixed circuit breaker incorporates a PR121/P-LI electronic overcurrent release for long-time overload and instantaneous short-circuit protection.

As part of the proven ABB SACE Emax range, the E1N 1250 combines robust high-current switching capability with electronic protection for demanding industrial, commercial and infrastructure installations. The PR121/P-LI R1250 release provides LI protection, helping protect cables, busbars and connected equipment against sustained overloads and severe short-circuit currents.

This configuration features a four-pole fixed design with horizontal rear terminals, a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 50 kA at 400 V AC. Four auxiliary change-over contacts provide circuit-breaker status signalling, making the 1SDA055736R1 well suited to substantial low-voltage distribution installations.

Key Advantages

  • Heavy-duty 1250 A SACE Emax air circuit breaker for high-current low-voltage distribution.
  • Four-pole fixed configuration for permanent switchboard installations.
  • Electronic PR121/P-LI R1250 overcurrent release for dependable circuit protection.
  • LI functionality provides long-time overload and instantaneous short-circuit protection.
  • 50 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Horizontal rear terminals facilitate integration with compatible switchboard busbar systems.
  • Four auxiliary change-over contacts support circuit-breaker status signalling.

Key Features

  • ABB SACE Emax E1N 1250 circuit breaker platform.
  • 1250 A rated current.
  • Four-pole configuration.
  • Fixed (F) execution.
  • Horizontal rear (HR) terminal arrangement.
  • PR121/P-LI R1250 electronic overcurrent release.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • 50 kA ultimate and service short-circuit breaking capacity at 400 V AC.
  • 50 kA for 1 s short-time withstand current.
  • Four auxiliary change-over contacts.

Reliable Protection for High-Current Low-Voltage Distribution

Air circuit breakers such as the ABB SACE Emax E1N are designed to switch and protect high-current low-voltage distribution circuits. The electronic overcurrent release supervises circuit current so that the breaker can respond to abnormal conditions before sustained overloads or severe short circuits cause extensive damage to conductors, busbars and connected electrical equipment.

The PR121/P-LI R1250 release provides long-time overload and instantaneous short-circuit protection. Combined with the 1250 A E1N platform, four-pole fixed construction, horizontal rear terminals and 50 kA short-circuit performance, this makes the ABB 1SDA055736R1 particularly suitable for main distribution and feeder applications requiring dependable high-current circuit protection.

Typical Applications

  • Main low-voltage switchboards and distribution boards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • Main incomer and high-current feeder protection.
  • Transformer and generator distribution systems.
  • Four-pole fixed switchgear requiring electronic LI overcurrent protection.

Technical Specifications

Series SACE Emax
Frame E1N 1250
Order code 1SDA055736R1
Product type Air circuit breaker
Rated current (In) 1250 A
Rated uninterrupted current (Iu) 1250 A
Rated operational current (Ie) 1250 A
Number of poles 4
Execution Fixed (F)
Terminal arrangement Horizontal rear (HR)
Trip unit PR121/P-LI R1250
Release type Electronic overcurrent release
Protection functions Long-time and instantaneous (LI)
Rated operational voltage 690 V AC
Rated voltage 690 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 50 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 50 kA
Short-time withstand current (Icw) 50 kA for 1 s; 36 kA for 3 s
Short-circuit performance level N
Overload release setting range 500–1250 A
Instantaneous short-circuit release setting range 1875–18750 A
Integrated earth-fault protection No
Auxiliary contacts 4 change-over contacts
Power loss 150 W
Electrical durability 8000 cycles
Mechanical durability 25000 cycles
Current type AC
Standard IEC
ABB product group 310513-New Emax

Frequently Asked Questions

What is the ABB 1SDA055736R1?

The ABB 1SDA055736R1 is a SACE Emax E1N 1250 four-pole fixed air circuit breaker rated at 1250 A and equipped with a PR121/P-LI R1250 electronic overcurrent release.

What is the current rating of the ABB 1SDA055736R1?

The ABB 1SDA055736R1 has a rated current of 1250 A.

What protection functions does the PR121/P-LI trip unit provide?

The PR121/P-LI electronic release provides long-time overload protection and instantaneous short-circuit protection.

How many poles does the ABB 1SDA055736R1 have?

The ABB 1SDA055736R1 has a four-pole configuration for low-voltage power distribution applications.

Is the ABB 1SDA055736R1 fixed or withdrawable?

The ABB 1SDA055736R1 is a fixed (F) air circuit breaker with horizontal rear terminals for permanent installation within compatible low-voltage switchgear.

What is the breaking capacity of the ABB 1SDA055736R1?

The ABB 1SDA055736R1 has an ultimate short-circuit breaking capacity of 50 kA at 400 V AC, with a matching 50 kA service short-circuit breaking capacity.