1SDA055717R1 ABB E1N800 PR122/P-LSIG 800A 3P Withdrawable Air Circuit Breaker

1SDA055717R1 ABB E1N800 PR122/P-LSIG 800A 3P Withdrawable Air Circuit Breaker

ABB 1SDA055717R1 SACE Emax E1N800 three-pole withdrawable air circuit breaker moving part rated at 800 A with a PR122/P-LSIG R800 electronic trip unit providing comprehensive LSIG protection for low-voltage power distribution systems.

SKU: 1SDA055717R1MPN: 1SDA055717R1
Price
List Price £12,108.97 ex VAT
Your Price (ex VAT) Save 25%
£9,081.73 25% OFF
You save £3,027.24 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,081.73
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,081.73

Why Choose the ABB E1N800 PR122/P-LSIG 800A 3P Withdrawable Air Circuit Breaker?

The ABB E1N800 PR122/P-LSIG, order code 1SDA055717R1, is a high-performance SACE Emax air circuit breaker moving part designed for switching and comprehensive protection in low-voltage power distribution systems. Rated at 800 A, this three-pole unit combines the E1N frame with the PR122/P-LSIG R800 electronic overcurrent release.

This model is supplied as a withdrawable moving part (W MP) for installation with the corresponding SACE Emax fixed part. The withdrawable design enables the breaker to be isolated and removed for inspection, maintenance or replacement, making it particularly suitable for industrial switchboards where serviceability and continuity of operation are important.

The PR122/P-LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. With a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 50 kA at 400–415 V AC, the E1N800 provides comprehensive protection for demanding power distribution applications.

Key Advantages

  • High-performance ABB SACE Emax E1N air circuit breaker moving part.
  • 800 A rated uninterrupted current for substantial low-voltage distribution loads.
  • Three-pole withdrawable configuration for maintainable switchboard installations.
  • Advanced PR122/P-LSIG R800 electronic overcurrent release.
  • Comprehensive LSIG protection against overloads, short circuits and ground faults.
  • 50 kA Icu at 400–415 V AC for demanding fault-current conditions.
  • 50 kA short-time withstand current for 1 s.
  • Four auxiliary contacts provide circuit-breaker status signalling.

Key Features

  • ABB SACE Emax E1N series.
  • 800 A rated uninterrupted current.
  • Three-pole (3P) construction.
  • Withdrawable moving part (W MP) configuration.
  • PR122/P-LSIG R800 electronic trip unit.
  • LSIG protection: long-time, short-time, instantaneous and ground fault.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 50 kA Icu and Ics at 400–415 V AC.
  • 50 kA Icw for 1 s and 36 kA for 3 s.
  • Four auxiliary contacts and open/closed position indication.
  • Designed for installation with the corresponding E1 withdrawable fixed part.

Comprehensive Protection for Low-Voltage Power Distribution

The ABB SACE Emax E1N800 is engineered for switching, isolation and protection of high-current low-voltage distribution circuits. Its withdrawable construction enables the moving portion to be separated from the corresponding fixed part, supporting efficient maintenance, testing and replacement in critical switchboard installations.

The PR122/P-LSIG electronic release provides coordinated protection against overloads, delayed and instantaneous short circuits and ground faults. Combined with the E1N platform's 50 kA breaking capability, the 1SDA055717R1 provides a robust solution for main incomers, feeders and other critical distribution circuits requiring comprehensive LSIG protection.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main incoming circuit protection.
  • High-current feeder protection.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Infrastructure power distribution systems.
  • Withdrawable switchgear requiring comprehensive LSIG protection.

Technical Specifications

Series SACE Emax
Product group New Emax
Order code 1SDA055717R1
Product type Air circuit breaker moving part
Frame / sub-type E1N
Rated current 800 A
Rated uninterrupted current 800 A
Number of poles 3P
Version Withdrawable
Configuration Moving part (W MP)
Trip unit PR122/P-LSIG R800
Release type Electronic
Protection functions Long-time, short-time, instantaneous and ground fault (LSIG)
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 50 kA
Rated service short-circuit breaking capacity (Ics) at 400–415 V AC 50 kA
Rated short-time withstand current (Icw) 50 kA for 1 s; 36 kA for 3 s
Overload release setting range 400–800 A
Short-time short-circuit release setting range 480–8000 A
Instantaneous short-circuit release setting range 1200–12000 A
Integrated ground-fault protection Yes
Protection degree IP20
Auxiliary contacts 2 NO + 2 NC
Position indication Circuit breaker open / closed
Motor operating mechanism Optional
Mechanical durability 25,000 cycles
Power loss 95 W
Product net weight 55 kg
EAN 8015644570576

Frequently Asked Questions

What is the ABB 1SDA055717R1?

It is an ABB SACE Emax E1N800 800 A three-pole withdrawable air circuit breaker moving part equipped with a PR122/P-LSIG R800 electronic overcurrent release.

What is the rated current of the ABB E1N800 1SDA055717R1?

The circuit breaker has a rated uninterrupted current of 800 A.

What protection does the PR122/P-LSIG trip unit provide?

The PR122/P-LSIG provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection, collectively identified as LSIG protection.

What is the breaking capacity of the ABB E1N800 1SDA055717R1?

The breaker has a rated ultimate short-circuit breaking capacity of 50 kA at 400–415 V AC and a rated short-time withstand current of 50 kA for 1 s.

Is the ABB 1SDA055717R1 fixed or withdrawable?

The 1SDA055717R1 is a withdrawable moving part designed for installation with the corresponding fixed part of an ABB SACE Emax circuit-breaker assembly.