1SDA055688R1 ABB E1B 1600 PR121/P-LI 1600A 4-Pole Withdrawable Air Circuit Breaker

1SDA055688R1 ABB E1B 1600 PR121/P-LI 1600A 4-Pole Withdrawable Air Circuit Breaker

ABB 1SDA055688R1 SACE Emax E1B 1600 is a 1600 A four-pole withdrawable air circuit breaker moving part with a PR121/P-LI R1600 electronic trip unit providing LI protection and 42 kA short-circuit breaking capacity across 220–690 V AC.

SKU: 1SDA055688R1MPN: 1SDA055688R1
Price
List Price £14,786.91 ex VAT
Your Price (ex VAT) Save 25%
£11,090.18 25% OFF
You save £3,696.73 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,090.18
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,090.18

Why Choose the ABB E1B 1600 PR121/P-LI 1600A Air Circuit Breaker?

The ABB E1B 1600 PR121/P-LI, order code 1SDA055688R1, is a high-performance 1600 A four-pole withdrawable air circuit breaker moving part designed for protection and switching in demanding low-voltage electrical distribution systems. Part of the established ABB SACE Emax / New Emax range, it combines the E1B frame's robust circuit-breaking capability with a PR121/P-LI R1600 electronic overcurrent release.

The fitted PR121/P-LI R1600 electronic trip unit provides long-time overload and instantaneous short-circuit protection. Its adjustable protection settings enable the breaker to be coordinated with the characteristics of the protected circuit, helping safeguard cables, busbars, switchgear and connected equipment against sustained overloads and severe short-circuit currents.

Supplied as a withdrawable moving part, this four-pole breaker is designed for use with the appropriate ABB SACE Emax fixed part or cradle. The withdrawable arrangement facilitates isolation and maintenance, while four auxiliary contacts, open/closed position indication and trip indication support integration with switchboard control and monitoring systems.

Key Advantages

  • High-current 1600 A air circuit breaker moving part for demanding low-voltage distribution systems.
  • Four-pole configuration supports three-phase four-wire systems requiring neutral switching.
  • PR121/P-LI R1600 electronic trip unit provides long-time overload and instantaneous short-circuit protection.
  • 42 kA Icu and Ics across the specified 220–690 V AC operating range.
  • 42 kA short-time withstand current for 1 s supports demanding high-current applications.
  • Adjustable 640–1600 A overload release range enables circuit-specific protection settings.
  • Withdrawable construction facilitates circuit isolation, inspection, servicing and replacement.
  • Four auxiliary contacts and trip indication support switchboard signalling and automation.

Key Features

  • ABB SACE Emax E1B series.
  • 1600 A rated current.
  • Four-pole configuration.
  • PR121/P-LI R1600 electronic overcurrent release.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • 640–1600 A overload release adjustment range.
  • 2400–24,000 A instantaneous short-circuit adjustment range.
  • 690 V AC rated operational voltage.
  • 42 kA rated ultimate and service short-circuit breaking capacity across 220–690 V AC.
  • 42 kA Icw for 1 s and 36 kA for 3 s.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Withdrawable moving-part construction for service-friendly switchboard integration.

Electronic LI Protection for 1600A Four-Pole Power Distribution

Air circuit breakers such as the ABB SACE Emax E1B protect high-current electrical distribution systems by detecting and interrupting abnormal current conditions before cables, busbars, switchgear and connected equipment can sustain serious damage. The E1B 1600 combines a continuous current capability of 1600 A with 42 kA ultimate and service short-circuit breaking capacities across its specified 220–690 V AC operating range.

The PR121/P-LI electronic release combines adjustable long-time overload protection with instantaneous short-circuit protection. The long-time function protects against sustained overcurrents, while the instantaneous function rapidly interrupts severe short-circuit currents. Combined with four-pole switching and withdrawable construction, the 1SDA055688R1 is well suited to three-phase four-wire switchboards requiring dependable protection and convenient breaker isolation for maintenance.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Main incoming circuit protection.
  • High-current feeder circuit protection.
  • Three-phase four-wire electrical distribution systems.
  • Manufacturing plants and production facilities.
  • Commercial and infrastructure power distribution.
  • Generator and transformer secondary distribution systems.
  • Switchboards requiring withdrawable 1600 A four-pole circuit breakers.

Technical Specifications

Series SACE Emax / New Emax
ABB order code 1SDA055688R1
ABB product group 310513-New Emax
Product type Air circuit breaker moving part
Frame / sub-type E1B 1600
Short-circuit performance level B
Rated current (In) 1600 A
Rated operational current (Ie) 1600 A
Rated uninterrupted current (Iu) 1600 A
Number of poles 4
Current type AC
Rated operational voltage 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) 42 kA at 220–690 V AC
Rated service short-circuit breaking capacity (Ics) 42 kA at 220–690 V AC
Rated short-time withstand current (Icw) 42 kA for 1 s
Trip unit PR121/P-LI R1600
Release type Electronic
Protection functions L and I
Long-time protection Overload protection
Overload release adjustment range 640–1600 A
Instantaneous protection Short-circuit protection
Instantaneous short-circuit adjustment range 2400–24,000 A
Earth-fault protection Not integrated
Execution Withdrawable
Component Moving part (MP)
Main-circuit connection Through compatible separate fixed part / cradle
Auxiliary contacts 4 total, 2 NO + 2 NC
Position indication Circuit breaker open / closed
Trip indication Yes
Operating element Push-button
Integrated motor operator No
Optional motor operator Yes
Degree of protection IP2X
Power loss 378 W
Electrical durability 10,000 cycles at ≤440 V; 8000 cycles at 500–690 V
Electrical operating frequency 30 cycles per hour
Mechanical durability 25,000 cycles
Mechanical operating frequency 60 cycles per hour
Product dimensions (W × H × D) 414 × 461 × 396.5 mm
Product net weight 54 kg
Standard IEC
Customs tariff number 85362090
EAN 8015644570286

Frequently Asked Questions

What is the ABB 1SDA055688R1 used for?

The ABB 1SDA055688R1 is a 1600 A four-pole SACE Emax withdrawable air circuit breaker moving part designed for switching and protecting high-current low-voltage industrial and commercial electrical distribution systems.

What protection functions does the PR121/P-LI trip unit provide?

The PR121/P-LI R1600 electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection, with adjustable settings for coordination with the protected circuit.

What is the breaking capacity of the ABB E1B 1600?

The E1B 1600 has rated ultimate and service short-circuit breaking capacities of 42 kA across 220–690 V AC, together with rated short-time withstand currents of 42 kA for 1 s and 36 kA for 3 s.

Is the ABB 1SDA055688R1 fixed or withdrawable?

The 1SDA055688R1 is a withdrawable moving part designed for use with the appropriate compatible ABB SACE Emax fixed part or cradle, enabling convenient circuit isolation and breaker removal for inspection or maintenance.

Does the ABB 1SDA055688R1 include auxiliary contacts?

Yes. The breaker moving part is fitted with four auxiliary contacts comprising 2 NO and 2 NC contacts, together with open/closed position indication and trip indication for switchboard signalling and monitoring.

Trusted by Industrial Power Professionals Worldwide

ABB SACE Emax air circuit breakers are widely used in low-voltage distribution systems where dependable high-current switching, electronic overcurrent protection and service-friendly withdrawable construction are required.