ABB 1SDA055681R1 SACE Emax E1B 1600 is a 1600 A three-pole withdrawable air circuit breaker moving part with a PR121/P-LSI R1600 electronic trip unit providing LSI protection and 42 kA short-circuit breaking capacity across 220–690 V AC.

SKU: 1SDA055681R1Alt SKU: E1B 1600MPN: 1SDA055681R1
Price
List Price £12,000.21 ex VAT
Your Price (ex VAT) Save 25%
£9,000.16 25% OFF
You save £3,000.05 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,000.16
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,000.16

Why Choose the ABB E1B 1600 PR121/P-LSI 1600A Air Circuit Breaker?

The ABB E1B 1600 PR121/P-LSI, order code 1SDA055681R1, is a high-performance 1600 A three-pole withdrawable air circuit breaker moving part designed for protection and switching in demanding low-voltage electrical distribution systems. Part of the established ABB SACE Emax / New Emax range, it combines the E1B frame's robust circuit-breaking capability with a PR121/P-LSI R1600 electronic overcurrent release.

The fitted PR121/P-LSI R1600 electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. This LSI configuration supports selective protection and coordination within distribution networks, helping protect cables, busbars, switchgear and connected equipment against sustained overloads and severe short-circuit conditions.

Supplied as a withdrawable moving part, the breaker is designed for use with the appropriate SACE Emax fixed part or cradle. Its withdrawable construction facilitates isolation, inspection and maintenance, while four auxiliary contacts and open/closed position indication support integration with switchboard signalling, monitoring and control systems.

Key Advantages

  • High-current 1600 A air circuit breaker moving part for demanding low-voltage distribution systems.
  • PR121/P-LSI R1600 electronic trip unit provides dependable electronic overcurrent protection.
  • LSI protection functions cover long-time overload, short-time delayed and instantaneous short-circuit conditions.
  • 42 kA Icu and Ics across the specified 220–690 V AC range.
  • 42 kA short-time withstand current for 1 s supports demanding distribution applications.
  • Withdrawable construction facilitates circuit isolation, inspection, servicing and replacement.
  • Four auxiliary contacts support remote circuit-breaker status signalling.
  • Open/closed position indication assists switchboard monitoring and automation.

Key Features

  • ABB SACE Emax E1B series.
  • 1600 A rated current.
  • Three-pole configuration.
  • PR121/P-LSI R1600 electronic overcurrent release.
  • Long-time (L) overload protection.
  • Short-time (S) delayed short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • 690 V AC rated operational voltage.
  • 42 kA rated ultimate and service short-circuit breaking capacity across 220–690 V AC.
  • 42 kA Icw for 1 s and 36 kA for 3 s.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Withdrawable moving-part construction.
  • Four auxiliary contacts with open/closed position indication.

Selective LSI Protection for 1600A Power Distribution

Air circuit breakers such as the ABB SACE Emax E1B protect high-current electrical distribution systems by detecting and interrupting abnormal current conditions before cables, busbars, switchgear and connected equipment can sustain serious damage. The E1B 1600 combines a continuous current capability of 1600 A with 42 kA ultimate and service short-circuit breaking capacities throughout its specified 220–690 V AC operating range.

The PR121/P-LSI electronic release combines long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection within one trip unit. The short-time function supports selective protection strategies by allowing coordinated fault clearing with downstream protective devices, while the withdrawable moving-part construction enables convenient isolation and removal of the breaker for inspection, servicing or replacement.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Main incoming circuit protection.
  • High-current feeder circuit protection.
  • Three-phase electrical distribution systems.
  • Manufacturing plants and production facilities.
  • Commercial and infrastructure power distribution.
  • Generator and transformer secondary distribution systems.
  • Switchboards requiring withdrawable circuit breakers with selective LSI protection.

Technical Specifications

Series SACE Emax / New Emax
ABB order code 1SDA055681R1
ABB product group 310513-New Emax
Product type Air circuit breaker moving part
Frame / sub-type E1B 1600
Short-circuit performance level B
Rated current (In) 1600 A
Rated operational current (Ie) 1600 A
Rated uninterrupted current (Iu) 1600 A
Number of poles 3
Current type AC
Rated operational voltage 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) 42 kA at 220–690 V AC
Rated service short-circuit breaking capacity (Ics) 42 kA at 220–690 V AC
Rated short-time withstand current (Icw) 42 kA for 1 s
Trip unit PR121/P-LSI R1600
Release type Electronic
Protection functions L, S and I
Long-time protection Overload protection
Short-time protection Delayed short-circuit protection
Instantaneous protection Short-circuit protection
Earth-fault protection (G) Not included
Execution Withdrawable
Component Moving part (MP)
Terminal connection type Withdrawable circuit breaker
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Power loss 378 W
Electrical durability 10,000 cycles at ≤440 V; 8000 cycles at 500–690 V
Electrical operating frequency 30 cycles per hour
Mechanical durability 25,000 cycles
Mechanical operating frequency 60 cycles per hour
Product dimensions (W × H × D) 324 × 461 × 396.5 mm
Product net weight 44 kg
Standard IEC
Customs tariff number 85362090
EAN 8015644570217

Frequently Asked Questions

What is the ABB 1SDA055681R1 used for?

The ABB 1SDA055681R1 is a 1600 A three-pole SACE Emax withdrawable air circuit breaker moving part designed for switching and protecting high-current low-voltage industrial and commercial electrical distribution systems.

What protection functions does the PR121/P-LSI trip unit provide?

The PR121/P-LSI R1600 electronic trip unit provides long-time overload (L), short-time delayed short-circuit (S) and instantaneous short-circuit (I) protection.

What is the breaking capacity of the ABB E1B 1600?

The E1B 1600 has rated ultimate and service short-circuit breaking capacities of 42 kA across 220–690 V AC, together with rated short-time withstand currents of 42 kA for 1 s and 36 kA for 3 s.

Is the ABB 1SDA055681R1 fixed or withdrawable?

The 1SDA055681R1 is a withdrawable moving part designed for use with the appropriate compatible ABB SACE Emax fixed part or cradle, enabling convenient circuit isolation and breaker removal for maintenance.

What is the difference between LSI and LSIG protection?

LSI provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Unlike an LSIG release, the PR121/P-LSI configuration does not include the additional G earth-fault protection function.