1SDA055649R1 ABB E1B 1250 PR121/P-LSI 1250 A 3-Pole Withdrawable Air Circuit Breaker Moving Part

1SDA055649R1 ABB E1B 1250 PR121/P-LSI 1250 A 3-Pole Withdrawable Air Circuit Breaker Moving Part

ABB 1SDA055649R1 E1B 1250 PR121/P-LSI is a 1250 A three-pole SACE Emax withdrawable air circuit breaker moving part with a PR121/P-LSI R1250 electronic trip unit providing long-time, short-time and instantaneous overcurrent protection.

SKU: 1SDA055649R1Alt SKU: EIB 1250 3P WMPMPN: 1SDA055649R1
Price
List Price £11,102.36 ex VAT
Your Price (ex VAT) Save 25%
£8,326.77 25% OFF
You save £2,775.59 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,326.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,326.77

Why Choose the ABB E1B 1250 PR121/P-LSI Air Circuit Breaker Moving Part?

The ABB E1B 1250 PR121/P-LSI, order code 1SDA055649R1, is a SACE Emax withdrawable air circuit breaker moving part designed for reliable protection and switching in high-current low-voltage distribution systems. This three-pole configuration combines a 1,250 A rated current with the PR121/P-LSI R1250 electronic overcurrent release for long-time overload, short-time short-circuit and instantaneous short-circuit protection.

Part of the ABB SACE Emax E1 series, this E1B 1250 moving part is intended for use with a compatible withdrawable circuit-breaker fixed part. The withdrawable construction supports efficient inspection, servicing and replacement in industrial switchboards while allowing the fixed portion of the breaker assembly to remain installed.

The E1B performance level delivers a rated ultimate and service short-circuit breaking capacity of 42 kA at 400/415 V AC. A rated short-time withstand current of 42 kA for 1 s, together with the adjustable PR121/P-LSI protection functions, makes this breaker suitable for demanding distribution systems where protection selectivity and serviceability are important.

Key Advantages

  • High-capacity 1,250 A SACE Emax circuit-breaker moving part for low-voltage distribution.
  • PR121/P-LSI electronic trip unit provides long-time, short-time and instantaneous overcurrent protection.
  • Three-pole withdrawable configuration supports convenient servicing and replacement.
  • 42 kA Icu and Ics at 400/415 V AC.
  • 42 kA short-time withstand current for 1 s supports demanding distribution applications.
  • Four change-over auxiliary contacts and open/closed position indication support signalling and monitoring.

Key Features

  • ABB SACE Emax E1B series.
  • 1,250 A rated uninterrupted current.
  • Three-pole configuration.
  • Withdrawable moving part for a compatible SACE Emax fixed part.
  • PR121/P-LSI R1250 electronic overcurrent release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • 1,000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 42 kA Icu and Ics at 400/415 V AC.
  • 42 kA Icw for 1 s and 36 kA for 3 s.
  • Four change-over auxiliary contacts.
  • Open/closed circuit-breaker position indication.

Adjustable LSI Protection in a Withdrawable Design

The ABB SACE Emax E1B combines high-current switching capability with electronic protection for critical low-voltage distribution circuits. Its PR121/P-LSI R1250 release provides adjustable long-time overload, short-time delayed and instantaneous short-circuit protection, helping safeguard cables, busbars, transformers and downstream equipment while supporting coordinated protection schemes.

The three-pole withdrawable moving-part configuration is particularly useful in switchboards where maintainability and continuity of service are important. The moving part can be withdrawn from its compatible fixed part for inspection or servicing, while four change-over auxiliary contacts and open/closed position indication allow breaker status to be incorporated into signalling, monitoring and control systems.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Withdrawable switchgear assemblies.
  • Commercial and infrastructure electrical installations.
  • Transformer secondary distribution circuits.
  • Generator and standby power distribution.
  • Manufacturing and process plant switchgear.

Technical Specifications

Series SACE Emax E1
ABB order code 1SDA055649R1
Product group New Emax
Product type Air circuit breaker moving part
Rated current (In) 1250 A
Rated uninterrupted current (Iu) 1250 A
Rated operational current (Ie) 1250 A
Number of poles 3
Execution Withdrawable moving part
Trip unit PR121/P-LSI R1250
Release type Electronic
Protection functions L-S-I (long-time, short-time and instantaneous)
Overload release current setting 500–1250 A
Short-time delayed short-circuit setting 1250–12500 A
Instantaneous short-circuit setting 1875–18750 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 42 kA
Rated service short-circuit breaking capacity (Ics) at 400/415 V AC 42 kA
Rated short-time withstand current (Icw), 1 s 42 kA
Rated short-time withstand current (Icw), 3 s 36 kA
Short-circuit performance level B
Integrated earth-fault protection No
Auxiliary contacts 4 change-over contacts
Position indication Open / closed
Motor drive Optional
Mechanical durability 25,000 cycles
Electrical durability at up to 440 V 10,000 cycles
Electrical durability at 500–690 V 8,000 cycles
Power loss 230 W
Product dimensions (W × H × D) 324 × 461 × 396.5 mm
Product net weight 44 kg
Standard IEC
EAN 8015644569891

Frequently Asked Questions

What is the ABB 1SDA055649R1?

The ABB 1SDA055649R1 is an E1B 1250 three-pole SACE Emax withdrawable circuit-breaker moving part rated at 1,250 A and equipped with a PR121/P-LSI R1250 electronic overcurrent release.

What protection does the PR121/P-LSI trip unit provide?

The PR121/P-LSI electronic release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E1B 1250?

The E1B 1250 has rated ultimate and service short-circuit breaking capacities of 42 kA at 400/415 V AC.

What are the protection adjustment ranges of the ABB 1SDA055649R1?

The overload release is adjustable from 500–1250 A, the short-time delayed short-circuit release from 1250–12500 A, and the instantaneous short-circuit release from 1875–18750 A.

Is the ABB 1SDA055649R1 a complete withdrawable circuit breaker?

The 1SDA055649R1 is the withdrawable moving part and is intended for use with a compatible ABB SACE Emax fixed part to form a complete withdrawable circuit-breaker assembly.

Trusted Low-Voltage Protection from ABB

ABB SACE Emax air circuit breakers provide dependable protection and control for low-voltage power distribution systems, combining high-current switching capability, adjustable electronic protection and service-friendly withdrawable construction for demanding industrial, commercial and infrastructure installations.