1SDA055641R1 ABB E1B 1250 PR121/P-LSI 1250 A 4-Pole Air Circuit Breaker

1SDA055641R1 ABB E1B 1250 PR121/P-LSI 1250 A 4-Pole Air Circuit Breaker

ABB 1SDA055641R1 E1B 1250 PR121/P-LSI is a 1250 A four-pole fixed SACE Emax air circuit breaker with rear horizontal terminals and a PR121/P-LSI R1250 electronic trip unit providing long-time, short-time and instantaneous overcurrent protection.

SKU: 1SDA055641R1MPN: 1SDA055641R1
Price
List Price £13,293.61 ex VAT
Your Price (ex VAT) Save 25%
£9,970.21 25% OFF
You save £3,323.40 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,970.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,970.21

Why Choose the ABB E1B 1250 PR121/P-LSI Air Circuit Breaker?

The ABB E1B 1250 PR121/P-LSI, order code 1SDA055641R1, is a SACE Emax air circuit breaker designed for dependable switching and protection in high-current low-voltage power distribution systems. This four-pole fixed circuit breaker combines a 1,250 A rated current with the PR121/P-LSI R1250 electronic overcurrent release for long-time overload, short-time short-circuit and instantaneous short-circuit protection.

Part of the proven ABB SACE Emax E1 series, the E1B 1250 is suitable for industrial switchboards, commercial distribution assemblies and infrastructure installations requiring reliable high-current circuit protection. Its four-pole configuration supports three-phase four-wire systems, while the electronic LSI release enables coordinated protection of feeders, busbars and connected equipment.

This model is a four-pole fixed circuit breaker equipped with rear horizontal terminals. It is rated for operation up to 690 V AC and provides a rated ultimate and service short-circuit breaking capacity of 42 kA at 400/415 V AC, together with a short-time withstand current of 42 kA for 1 s.

Key Advantages

  • High-capacity 1,250 A SACE Emax air circuit breaker for demanding low-voltage distribution.
  • PR121/P-LSI electronic trip unit provides long-time, short-time and instantaneous overcurrent protection.
  • Four-pole configuration supports three-phase four-wire electrical distribution systems.
  • 42 kA Icu and Ics at 400/415 V AC.
  • Rear horizontal terminals provide a practical interface with switchboard busbars.
  • Four auxiliary contacts and open/closed position indication support signalling and monitoring.

Key Features

  • ABB SACE Emax E1B series.
  • 1,250 A rated uninterrupted current.
  • Four-pole configuration.
  • Fixed circuit-breaker execution.
  • Rear horizontal terminal arrangement.
  • PR121/P-LSI R1250 electronic overcurrent release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • 1,000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 42 kA Icu and Ics at 400/415 V AC.
  • 42 kA Icw for 1 s and 36 kA for 3 s.

Electronic LSI Protection for High-Current Distribution

The ABB SACE Emax E1B provides switching, isolation and overcurrent protection for high-current low-voltage distribution circuits. Its PR121/P-LSI electronic release combines long-time overload protection with short-time and instantaneous short-circuit functions, helping protect cables, busbars and connected equipment against sustained overloads and high fault currents.

The four-pole fixed construction is well suited to three-phase four-wire switchboards requiring neutral switching alongside the phase conductors. Rear horizontal terminals facilitate integration with busbar systems, while four auxiliary contacts and open/closed position indication allow circuit-breaker status to be incorporated into signalling, monitoring and control systems.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Three-phase four-wire electrical networks.
  • Commercial building electrical distribution.
  • Infrastructure and utility installations.
  • Transformer secondary distribution circuits.
  • Generator and standby power distribution.

Technical Specifications

Series SACE Emax E1
ABB order code 1SDA055641R1
Product group New Emax
Product type Air circuit breaker
Rated current (In) 1250 A
Rated uninterrupted current (Iu) 1250 A
Rated operational current (Ie) 1250 A
Number of poles 4
Execution Fixed
Terminal arrangement Rear horizontal
Trip unit PR121/P-LSI R1250
Release type Electronic
Protection functions L-S-I (long-time, short-time and instantaneous)
Overload release setting range 500–1250 A
Short-time short-circuit setting range 1250–12500 A
Instantaneous short-circuit setting range 1875–18750 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 42 kA
Rated service short-circuit breaking capacity (Ics) at 400/415 V AC 42 kA
Rated short-time withstand current (Icw), 1 s 42 kA
Rated short-time withstand current (Icw), 3 s 36 kA
Short-circuit performance level B
Auxiliary contacts 4
Position indication Open / closed
Mechanical durability 25,000 cycles
Electrical durability at up to 440 V 10,000 cycles
Electrical durability at 500–690 V 8,000 cycles
Power loss 150 W
Dimensions (W × H × D) 386 × 418 × 302 mm
Net weight 50 kg
Standard IEC
EAN 8015644569815

Frequently Asked Questions

What is the ABB 1SDA055641R1?

The ABB 1SDA055641R1 is an E1B 1250 four-pole fixed SACE Emax air circuit breaker rated at 1,250 A, with rear horizontal terminals and a PR121/P-LSI R1250 electronic overcurrent release.

What protection does the PR121/P-LSI trip unit provide?

The PR121/P-LSI electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E1B 1250?

The E1B 1250 has rated ultimate and service short-circuit breaking capacities of 42 kA at 400/415 V AC.

What are the current adjustment ranges of the ABB 1SDA055641R1?

The overload release is adjustable from 500–1250 A, the short-time short-circuit setting from 1250–12500 A, and the instantaneous short-circuit setting from 1875–18750 A.

How is the ABB 1SDA055641R1 installed?

This model is a four-pole fixed circuit breaker with rear horizontal terminals, designed for permanent installation within compatible low-voltage switchboards and power distribution assemblies.

Trusted Low-Voltage Protection from ABB

ABB SACE Emax air circuit breakers provide dependable protection and control for low-voltage power distribution systems, combining high-current switching capability with electronic protection for demanding industrial, commercial and infrastructure installations.