ABB 1SDA055541R1 is a SACE Emax E4S/f 4000 A four-pole fixed air circuit breaker with a PR122/P-LSIG electronic trip unit providing LSIG protection for high-current low-voltage power distribution systems.
£33,295.54
The ABB E4S/f 4000 PR122/P-LSIG, order code 1SDA055541R1, is a high-current four-pole air circuit breaker (ACB) from the ABB SACE Emax range, designed for protection and switching in demanding low-voltage electrical distribution systems. Rated at 4000 A, this fixed circuit breaker combines the robust E4S platform with an advanced PR122/P-LSIG electronic protection release for comprehensive overload, short-circuit and earth-fault protection.
This Emax circuit breaker features a full-size neutral, fixed construction and rear horizontal terminals. The PR122/P-LSIG release provides long-time, short-time, instantaneous and ground-fault protection, enabling coordinated protection of high-current distribution networks while providing an additional protective function against earth faults.
Designed for systems with a rated operational voltage up to 690 V AC, the E4S/f platform provides an ultimate short-circuit breaking capacity of 80 kA at 415 V AC. Its combination of a 4000 A current rating, four-pole switching and electronic LSIG protection makes it suitable for main incomers, high-power feeders and major industrial distribution circuits.
Air circuit breakers such as the ABB E4S/f 4000 provide switching and protection for major low-voltage power circuits. Their high continuous-current and short-circuit ratings make them particularly suitable for incoming supplies, bus couplers and high-power feeders where dependable interruption of severe fault currents is essential.
The PR122/P-LSIG electronic release extends conventional overload and short-circuit protection with ground-fault protection. Long-time protection responds to sustained overloads, short-time protection supports selective coordination, instantaneous protection rapidly interrupts severe short circuits, and the ground-fault function provides additional protection against earth-fault currents.
| Series | SACE Emax |
|---|---|
| ABB order code | 1SDA055541R1 |
| EAN | 8015644568818 |
| Product type | Air circuit breaker |
| Frame | E4S/f |
| Rated current | 4000 A |
| Number of poles | 4 |
| Fourth pole rating | 100% |
| Neutral configuration | Full-size neutral |
| Installation | Fixed |
| Trip unit | PR122/P-LSIG R4000 |
| Protection functions | LSI + ground fault |
| Rated operational voltage | Up to 690 V AC |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 80 kA |
| Service short-circuit breaking capacity (Ics) at 415 V AC | 80 kA |
| Short-time withstand current (Icw), 1 s | 75 kA |
| Short-time withstand current (Icw), 3 s | 75 kA |
| Terminal arrangement | Rear horizontal |
| Auxiliary contacts | 4 |
| Product dimensions (W × H × D) | 746 × 418 × 302 mm |
| Net weight | 109 kg |
| Mechanical durability | 15,000 cycles |
ABB 1SDA055541R1 is an E4S/f 4000 four-pole fixed air circuit breaker from the SACE Emax range, rated at 4000 A and equipped with a PR122/P-LSIG electronic protection release.
The PR122/P-LSIG release provides long-time, short-time, instantaneous and ground-fault protection, commonly abbreviated as LSIG.
The E4S/f has an ultimate short-circuit breaking capacity of 80 kA at 415 V AC and a service short-circuit breaking capacity of 80 kA at the same voltage.
This model is a fixed circuit breaker fitted with rear horizontal main terminals.
Yes. The G function in the PR122/P-LSIG release provides ground-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
ABB SACE Emax air circuit breakers provide robust high-current switching and advanced electronic protection for industrial and commercial low-voltage distribution systems, helping protect critical electrical infrastructure against overloads, short circuits and ground faults.