1SDA054592R1 ABB T5N 630 Breaking Part 4p F F

1SDA054592R1 ABB T5N 630 Breaking Part 4p F F

ABB 1SDA054592R1 is a T5N 630 four-pole fixed breaking unit with front connections, a 630 A rated uninterrupted current and 36 kA ultimate short-circuit breaking capacity at 400 V AC for compatible SACE Tmax T5 circuit breaker configurations.

SKU: 1SDA054592R1MPN: 1SDA054592R1
Price
List Price £2,559.06 ex VAT
Your Price (ex VAT) Save 25%
£1,919.30 25% OFF
You save £639.77 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,919.30
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,919.30

Why Choose the ABB T5N 630 Breaking Part 4p F F?

The ABB T5N 630 Breaking Part 4p F F, order code 1SDA054592R1, is a four-pole breaking unit from the ABB SACE Tmax T moulded case circuit breaker range. Built on the T5N 630 platform, it provides the principal switching, current-carrying and fault-interruption section for compatible Tmax T5 circuit breaker configurations.

This breaking part has a rated uninterrupted current of 630 A and a rated voltage of 690 V AC. The T5N performance class provides a rated ultimate short-circuit breaking capacity of 36 kA at 400 V AC, making the unit suitable for industrial and commercial power distribution systems with substantial prospective fault currents.

The 1SDA054592R1 is supplied in a fixed four-pole configuration with front terminals and bolt-type main-circuit connections. Its modular design allows it to form the breaking section of a compatible ABB Tmax T5 assembly, while the four-pole arrangement supports three-phase distribution systems where switching of the neutral conductor is required.

Key Advantages

  • Genuine ABB SACE Tmax T5N 630 breaking unit.
  • 630 A rated uninterrupted current for high-power distribution.
  • Four-pole configuration for three-phase systems requiring a fourth switched pole.
  • 690 V AC rated voltage.
  • 36 kA ultimate breaking capacity at 400 V AC.
  • Fixed-mounted construction for panel and switchboard installation.
  • Front main-circuit connections with bolt-type terminals.
  • Motor operating mechanism can be added as an optional accessory.

Key Features

  • ABB SACE Tmax T series.
  • T5N 630 frame.
  • 630 A rated uninterrupted current.
  • Four-pole breaking part.
  • Fixed execution.
  • Front-terminal configuration.
  • 690 V AC rated voltage.
  • N short-circuit performance level.
  • 36 kA Icu at 400 V AC, 50 Hz.
  • IP20 degree of protection.
  • Toggle operating element.
  • Optional motor drive capability.

Reliable ABB Tmax T5 Four-Pole Breaking Unit

The breaking unit forms the principal current-carrying, switching and fault-interruption section of a modular moulded case circuit breaker. The T5N 630 combines a 630 A current rating with a 36 kA ultimate short-circuit breaking capacity at 400 V AC, providing dependable performance for industrial and commercial distribution systems.

Its four-pole configuration makes the unit particularly useful in three-phase systems where the neutral conductor must also be switched. Fixed installation, front connections and optional motor-operation capability support flexible integration into compatible ABB Tmax T5 switchboards and power distribution assemblies.

Typical Applications

  • ABB SACE Tmax T5 circuit breaker assemblies.
  • Four-pole industrial power distribution systems.
  • Three-phase systems requiring neutral switching.
  • Industrial and commercial switchboards.
  • Transformer and installation protection assemblies.
  • Machinery and process power distribution.
  • OEM electrical distribution and control equipment.

Technical Specifications

Series SACE Tmax T
ABB order code 1SDA054592R1
Product type Moulded case circuit breaker breaking unit / breaking part
Frame T5N 630
Performance level N
Rated uninterrupted current (Iu) 630 A
Number of poles 4
Rated voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 36 kA
Installation Fixed
Main-circuit connection position Front
Main-circuit connection type Bolt connection
Operating element Toggle
Degree of protection IP20
Integrated earth-fault protection No
Integrated undervoltage release No
Integrated motor drive No
Optional motor drive Yes
DIN rail mounting No
Compatible product family ABB SACE Tmax T5
Weight approx. 4.5 kg
Country of origin Italy
Customs tariff number 85389099
GTIN / EAN 8015644556907

Frequently Asked Questions

What is the ABB 1SDA054592R1?

The ABB 1SDA054592R1 is a T5N 630 four-pole fixed breaking unit with front connections for compatible ABB SACE Tmax T5 moulded case circuit breaker configurations.

What is the current rating of the ABB T5N 630 breaking part?

The T5N 630 breaking unit has a rated uninterrupted current of 630 A.

What voltage is the ABB 1SDA054592R1 rated for?

The breaking unit has a rated voltage of 690 V AC, making it suitable for a broad range of industrial power distribution systems.

What is the breaking capacity of the ABB T5N 630 breaking part?

The T5N 630 has a rated ultimate short-circuit breaking capacity of 36 kA at 400 V AC, 50 Hz.

How is the ABB T5N 630 1SDA054592R1 configured?

The unit has a fixed four-pole configuration with front bolt connections, an IP20 protection rating and provision for an optional motor drive.

Trusted ABB Circuit Breaker Components

ABB SACE Tmax breaking units provide a robust modular foundation for industrial moulded case circuit breaker assemblies, combining dependable fault interruption with flexible installation and accessory options for demanding power distribution systems.