1SDA054577R1 ABB T5N 400 Breaking Part 3P FF

1SDA054577R1 ABB T5N 400 Breaking Part 3P FF

ABB 1SDA054577R1 T5N 400 fixed three-pole breaking part with front terminals, a 400 A rated uninterrupted current and 36 kA ultimate short-circuit breaking capacity at 400 V AC for compatible SACE Tmax T5 circuit breaker assemblies.

SKU: 1SDA054577R1MPN: 1SDA054577R1
Price
List Price £794.81 ex VAT
Your Price (ex VAT) Save 25%
£596.11 25% OFF
You save £198.70 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £596.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£596.11

Why Choose the ABB T5N 400 Breaking Part 3P FF?

The ABB T5N 400 Breaking Part 3P FF, order code 1SDA054577R1, is a fixed three-pole breaking unit designed for use within ABB SACE Tmax T5 moulded case circuit breaker assemblies. As part of the ABB SACE Tmax T5 series, it provides the main current-carrying and fault-interruption section required to configure a T5N 400 circuit breaker with compatible ABB protection and operating components.

This product is supplied as a breaking part rather than a complete circuit breaker with protection unit. Its modular design allows the appropriate compatible ABB trip unit and accessories to be selected for the protection requirements of the installation, while the T5N breaking unit provides the switching and short-circuit interruption platform.

The 1SDA054577R1 features a 400 A rated uninterrupted current, three-pole configuration, fixed construction and front terminals. The T5N 400 platform has an ultimate short-circuit breaking capacity of 36 kA at 400 V AC, 50 Hz and a rated voltage of 690 V AC, making it suitable for a broad range of industrial power distribution applications.

Key Advantages

  • Genuine ABB SACE Tmax T5N 400 breaking part for compatible MCCB assemblies.
  • 400 A rated uninterrupted current for industrial power distribution systems.
  • Three-pole configuration for three-phase electrical applications.
  • 36 kA ultimate short-circuit breaking capacity at 400 V AC, 50 Hz.
  • Rated voltage of 690 V AC.
  • Fixed built-in construction for permanent switchboard installations.
  • Front-side main circuit connection for practical panel integration.
  • Compatible with optional motor-operated mechanisms within the Tmax T5 platform.

Key Features

  • ABB SACE Tmax T5 series.
  • T5N 400 breaking unit.
  • 400 A rated uninterrupted current (Iu).
  • Three-pole (3P) configuration.
  • Fixed (F) construction.
  • Front terminals (F).
  • 690 V AC rated voltage.
  • 36 kA Icu at 400 V AC, 50 Hz.
  • IP20 degree of protection.
  • Fixed built-in device construction.
  • Front-side main current circuit connection.
  • Designed for completion with compatible ABB Tmax T5 protection components.

Reliable Breaking Performance for Tmax T5 Assemblies

The breaking part forms the principal current-carrying and fault-interruption section of a moulded case circuit breaker. In a correctly configured ABB Tmax T5 assembly, it works with the selected compatible protection unit to interrupt fault currents and provide the switching platform required for industrial electrical distribution.

The T5N 400 platform combines a 400 A rated uninterrupted current with a 36 kA ultimate breaking capacity at 400 V AC. Its fixed three-pole design and front terminals make the 1SDA054577R1 particularly suitable for integration into industrial switchboards, distribution panels and OEM power assemblies where a modular ABB Tmax solution is required.

Typical Applications

  • ABB SACE Tmax T5 moulded case circuit breaker assemblies.
  • Industrial electrical power distribution systems.
  • Electrical switchboards and distribution panels.
  • Three-phase industrial feeder circuits.
  • Industrial machinery electrical distribution.
  • Commercial and infrastructure power distribution.
  • Power generation and energy installations.
  • OEM switchboards and electrical distribution assemblies.

Technical Specifications

Series SACE Tmax T5
ABB product group 310511-T-Max T4 - T8
Order code 1SDA054577R1
EAN 8015644556754
Product type MCCB breaking part / breaking unit
Suitable for ABB SACE Tmax T5 moulded case circuit breaker assemblies
Frame T5N 400
Rated uninterrupted current (Iu) 400 A
Number of poles 3
Rated voltage 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 36 kA
Construction Fixed built-in device
Main circuit connection position Front side
Terminal arrangement Front terminals
Degree of protection IP20
Complete device with protection unit No
Optional motor drive Yes
Mechanical durability 20,000 cycles
Mechanical operating rate 120 cycles per hour
Electrical durability 7,000 cycles
Electrical operating rate 60 cycles per hour
Dimensions (H × W × D) 205 × 140 × 103.5 mm
Net weight 3.25 kg

Frequently Asked Questions

What is the ABB 1SDA054577R1?

The ABB 1SDA054577R1 is a T5N 400 three-pole fixed breaking part with front terminals designed for use within compatible ABB SACE Tmax T5 moulded case circuit breaker assemblies.

Is the ABB 1SDA054577R1 a complete circuit breaker?

No. The 1SDA054577R1 is a breaking part and is not supplied as a complete device with a protection unit. It is intended to be combined with compatible ABB Tmax T5 components for the required circuit breaker configuration.

What is the current rating of the ABB T5N 400 breaking part?

The T5N 400 breaking part has a rated uninterrupted current of 400 A.

What is the breaking capacity of the ABB T5N 400?

The T5N 400 has an ultimate short-circuit breaking capacity of 36 kA at 400 V AC, 50 Hz.

How many poles does the ABB 1SDA054577R1 have?

The 1SDA054577R1 is a three-pole (3P) fixed breaking unit with front terminals.

Trusted ABB Circuit Protection

ABB SACE Tmax breaking units provide the robust current-carrying and fault-interruption platform required for compatible moulded case circuit breaker assemblies, supporting dependable switching and circuit protection in demanding industrial electrical distribution systems.