ABB 1SDA054565R1 T4L 250 fixed four-pole breaking part with front terminals, a 250 A rated uninterrupted current and high short-circuit breaking performance for compatible SACE Tmax T4 circuit breaker assemblies.
£1,751.54
The ABB T4L 250 Breaking Part 4P FF, order code 1SDA054565R1, is a fixed four-pole breaking unit designed for use within ABB SACE Tmax T4 moulded case circuit breaker assemblies. As part of the ABB SACE Tmax T4 series, it provides the main current-carrying and interruption section required to configure a T4L 250 circuit breaker with the appropriate compatible protection release.
This component is supplied as a breaking part rather than a complete circuit breaker, allowing suitable ABB Tmax T4 protection and operating components to be combined according to the requirements of the installation. The T4L performance level is designed for applications requiring high short-circuit interruption capability in industrial low-voltage distribution systems.
The 1SDA054565R1 has a 250 A rated uninterrupted current, four-pole configuration and fixed construction with front terminals. It is designed for operational voltages up to 690 V AC and 750 V DC and offers an ultimate short-circuit breaking capacity of up to 120 kA at 400–415 V AC.
The breaking part is the power interruption section of a moulded case circuit breaker and is designed to carry normal circuit current and interrupt high fault currents when operated by the appropriate protection system. The ABB T4L 250 platform provides high breaking performance for industrial electrical distribution systems where substantial prospective short-circuit currents may be present.
As a breaking unit, the 1SDA054565R1 is intended to form part of a correctly configured ABB Tmax T4 circuit breaker assembly rather than function as a complete standalone protective device. Its four-pole fixed construction, front terminals and high interruption capability make it suitable for integration into industrial switchboards and power distribution assemblies using compatible ABB components.
| Series | SACE Tmax T4 |
|---|---|
| ABB product group | 310511-T-Max T4 - T8 |
| Order code | 1SDA054565R1 |
| Product type | MCCB breaking part / breaking unit |
| Suitable for | ABB Tmax T4 moulded case circuit breakers |
| Frame | T4L 250 |
| Rated uninterrupted current (Iu) | 250 A |
| Number of poles | 4 |
| Rated operational voltage | 690 V AC / 750 V DC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Ultimate breaking capacity (Icu) at 220–230 V AC | 200 kA |
| Ultimate breaking capacity (Icu) at 380–415 V AC | 120 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 100 kA |
| Ultimate breaking capacity (Icu) at 500 V AC | 85 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 70 kA |
| DC breaking capacity at 250 V DC, 2 poles in series | 100 kA |
| DC breaking capacity at 500 V DC, 2 poles in series | 70 kA |
| DC breaking capacity at 750 V DC, 3 poles in series | 50 kA |
| Construction | Fixed |
| Main circuit connection | Front terminals |
| Mechanical durability | 20,000 cycles |
| Electrical durability | 8,000 cycles |
| Weight | approx. 3.5 kg |
| EAN | 8015644556631 |
The ABB 1SDA054565R1 is a T4L 250 four-pole fixed breaking part with front terminals designed for use in compatible ABB SACE Tmax T4 moulded case circuit breaker assemblies.
No. The 1SDA054565R1 is the breaking part of a Tmax T4 circuit breaker and is intended to be combined with the appropriate compatible ABB protection and operating components to form the required circuit breaker configuration.
The T4L 250 breaking part has a rated uninterrupted current of 250 A.
The T4L 250 provides an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, 100 kA at 440 V AC, 85 kA at 500 V AC and 70 kA at 690 V AC.