ABB 1SDA054561R1 is a T4V 250 three-pole fixed breaking unit with front terminals, a 250 A rated uninterrupted current and high V-level short-circuit performance for compatible SACE Tmax T4 circuit breaker assemblies.

SKU: 1SDA054561R1MPN: 1SDA054561R1
Price
List Price £2,592.44 ex VAT
Your Price (ex VAT) Save 25%
£1,944.33 25% OFF
You save £648.11 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,944.33
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,944.33

Why Choose the ABB T4V250 Breaking Part 3p FF?

The ABB T4V250 Breaking Part 3p FF, order code 1SDA054561R1, is a high-performance three-pole breaking unit from the ABB SACE Tmax T moulded case circuit breaker range. Designed around the T4V 250 frame, it provides the main switching and current-carrying section for compatible Tmax T4 circuit breaker configurations.

This breaking part uses the T4V 250 platform and is supplied in a fixed three-pole configuration with front terminals. It has a rated uninterrupted current of 250 A and is designed for operating voltages up to 690 V AC and 750 V DC, providing a robust foundation for demanding industrial circuit protection assemblies.

The V short-circuit performance level delivers an ultimate breaking capacity of 200 kA at 400/415 V AC and 150 kA at 690 V AC. As a breaking part rather than a complete circuit breaker with protection release, it is intended to be combined with compatible ABB Tmax T4 trip units and accessories appropriate to the required application.

Key Advantages

  • Genuine ABB SACE Tmax T4V 250 breaking unit.
  • 250 A rated uninterrupted current.
  • Three-pole configuration for three-phase electrical systems.
  • High V short-circuit performance level for demanding installations.
  • 200 kA Icu at 400/415 V AC.
  • 150 kA Icu at 690 V AC.
  • Fixed-mounted design with front terminals.
  • Designed for use with compatible ABB Tmax T4 trip units and accessories.

Key Features

  • ABB SACE Tmax T series.
  • T4V 250 frame.
  • 250 A rated uninterrupted current.
  • Three-pole breaking part.
  • Fixed execution with front terminals.
  • 690 V AC / 750 V DC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • 200 kA Icu at 400/415 V AC.
  • 150 kA Icu at 690 V AC.
  • Designed as the breaking section of a compatible Tmax T4 MCCB assembly.

High-Performance ABB Tmax T4 Breaking Unit

The breaking unit forms the main switching and fault-current interruption section of a modular moulded case circuit breaker. The T4V 250 version provides particularly high short-circuit performance, allowing compatible Tmax T4 assemblies to be used in industrial electrical systems with substantial prospective fault currents.

ABB's modular Tmax T architecture allows the breaking part to be combined with an appropriate protection release and compatible accessories. This enables the circuit breaker configuration to be matched to the protection requirements of industrial switchboards, machinery and power distribution installations.

Typical Applications

  • ABB SACE Tmax T4 circuit breaker assemblies.
  • Industrial switchboards and distribution panels.
  • High fault-level three-phase power distribution.
  • Industrial machinery and process installations.
  • Replacement and servicing of compatible Tmax T4 assemblies.
  • OEM electrical distribution and control equipment.

Technical Specifications

Series SACE Tmax T
ABB order code 1SDA054561R1
Product type Circuit breaker breaking unit / breaking part
Frame T4V 250
Performance level V
Rated uninterrupted current (Iu) 250 A
Number of poles 3
Rated operational voltage 690 V AC / 750 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated ultimate breaking capacity (Icu) at 220/230 V AC 200 kA
Rated ultimate breaking capacity (Icu) at 380/400/415 V AC 200 kA
Rated ultimate breaking capacity (Icu) at 440 V AC 180 kA
Rated ultimate breaking capacity (Icu) at 500 V AC 150 kA
Rated ultimate breaking capacity (Icu) at 690 V AC 150 kA
Rated service breaking capacity (Ics) at 400/415 V AC 200 kA
Rated service breaking capacity (Ics) at 690 V AC 150 kA
DC breaking capacity at 250 V DC, 2 poles in series 100 kA
DC breaking capacity at 500 V DC, 2 poles in series 70 kA
Installation Fixed
Terminal arrangement Front terminals
Electrical durability 8,000 cycles
Mechanical durability 20,000 cycles
Dimensions (H × W × D) 162 × 105 × 103.5 mm
Weight approx. 2.5 kg
Standard IEC
GTIN / EAN 8015644555993

Frequently Asked Questions

What is the ABB 1SDA054561R1?

The ABB 1SDA054561R1 is a T4V 250 three-pole fixed breaking unit with front terminals for compatible ABB SACE Tmax T4 moulded case circuit breaker configurations.

Is the ABB 1SDA054561R1 a complete circuit breaker?

No. It is a breaking part intended to form part of a compatible Tmax T4 circuit breaker assembly with the appropriate ABB trip unit and accessories.

What is the current rating of the T4V250 breaking part?

The breaking unit has a rated uninterrupted current of 250 A.

What is the breaking capacity of the ABB T4V250 breaking unit?

The T4V 250 breaking part provides an ultimate short-circuit breaking capacity of 200 kA at 400/415 V AC and 150 kA at 690 V AC.

How is the ABB T4V250 1SDA054561R1 installed?

It is a fixed three-pole breaking unit with front terminals, designed for integration into compatible industrial Tmax T4 circuit breaker assemblies.

Trusted ABB Circuit Breaker Components

ABB SACE Tmax breaking units provide a robust modular foundation for industrial moulded case circuit breaker assemblies, combining high short-circuit performance with flexible selection of compatible protection releases and accessories.