1SDA054558R1 ABB T4S 250 Breaking Part 3P F F

1SDA054558R1 ABB T4S 250 Breaking Part 3P F F

ABB 1SDA054558R1 is a SACE Tmax T4S 250 fixed three-pole MCCB breaking part with front terminals, a 250 A rated uninterrupted current and 50 kA breaking capacity at 400/415 V AC.

SKU: 1SDA054558R1Alt SKU: T4S250MPN: 1SDA054558R1
Price
List Price £701.76 ex VAT
Your Price (ex VAT) Save 25%
£526.32 25% OFF
You save £175.44 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £526.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£526.32

Why Choose the ABB T4S 250 Breaking Part 3P F F?

The ABB T4S 250 Breaking Part 3P F F, order code 1SDA054558R1, is a fixed three-pole breaking unit for the ABB SACE Tmax T4 moulded case circuit breaker platform. Designed as the breaking part of a modular Tmax T4 circuit breaker assembly, it provides the current-carrying and fault-interruption capability required when combined with a compatible ABB T4 protection release.

This T4S 250 version has a rated uninterrupted current of 250 A and the ABB S short-circuit performance level. Its ultimate and service short-circuit breaking capacities are both 50 kA at 400/415 V AC, with rated operational voltage extending to 690 V AC and 750 V DC.

The 1SDA054558R1 features a fixed three-pole configuration with front terminals, making it suitable for integration into industrial switchboards and power-distribution assemblies. As a breaking part rather than a complete circuit breaker with trip release, it is intended to be combined with compatible ABB Tmax T4 components to create the required protection configuration.

Key Advantages

  • Genuine ABB SACE Tmax T4S 250 breaking part.
  • 250 A rated uninterrupted current.
  • Three-pole fixed configuration for three-phase systems.
  • 50 kA Icu and Ics at 400/415 V AC.
  • Operational capability up to 690 V AC and 750 V DC.
  • Front terminals for straightforward switchboard integration.
  • Designed for combination with compatible ABB Tmax T4 protection releases and accessories.

Key Features

  • ABB SACE Tmax T4 series.
  • T4S 250 breaking unit.
  • 250 A rated uninterrupted current (Iu).
  • Three-pole configuration.
  • S short-circuit performance level.
  • 50 kA breaking capacity at 400/415 V AC.
  • 1000 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • Fixed circuit-breaker configuration.
  • Front terminals.
  • Electrical durability of 8000 operating cycles.
  • Mechanical durability of 20000 operating cycles.

High-Performance Breaking Unit for ABB Tmax T4 Circuit Breaker Assemblies

The ABB T4S 250 breaking part forms the power switching and fault-interruption section of a compatible Tmax T4 circuit breaker assembly. Unlike a complete MCCB supplied with a protection release, this component is intended to be combined with the appropriate ABB Tmax T4 trip unit and associated components to provide the required overload and short-circuit protection characteristics.

Its S performance level provides substantial fault-interruption capability, including 50 kA at 400/415 V AC and 25 kA at 690 V AC. Together with a 250 A current rating, fixed construction and front terminals, the 1SDA054558R1 provides a robust foundation for configurable industrial distribution protection.

Typical Applications

  • ABB SACE Tmax T4 circuit breaker assemblies.
  • Industrial low-voltage distribution switchboards.
  • Main and sub-distribution panels.
  • Manufacturing and process plant electrical systems.
  • Commercial and infrastructure power distribution.
  • Replacement or configuration of compatible Tmax T4 MCCB assemblies.

Technical Specifications

Series SACE Tmax T4
Order code 1SDA054558R1
Product type MCCB breaking part
Frame T4 250
Short-circuit performance level S
Rated uninterrupted current (Iu) 250 A
Number of poles 3
Rated operational voltage up to 690 V AC / 750 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Icu / Ics at 220–230 V AC 85 kA / 85 kA
Icu / Ics at 380–415 V AC 50 kA / 50 kA
Icu / Ics at 440 V AC 40 kA / 40 kA
Icu / Ics at 500 V AC 30 kA / 30 kA
Icu / Ics at 690 V AC 25 kA / 25 kA
DC breaking capacity at 250 V DC 50 kA with 2 poles in series
DC breaking capacity at 500 V DC 36 kA with 2 poles in series
DC breaking capacity at 750 V DC 25 kA with 3 poles in series
Mounting Fixed
Terminal configuration Front terminals
Electrical durability 8000 cycles
Mechanical durability 20000 cycles
Dimensions (W × H × D) 105 × 162 × 103.5 mm
Net weight 2.35 kg
EAN 8015644555962
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA054558R1?

The ABB 1SDA054558R1 is a T4S 250 fixed three-pole breaking part with front terminals for the SACE Tmax T4 moulded case circuit breaker platform.

Is the ABB 1SDA054558R1 a complete circuit breaker?

No. The 1SDA054558R1 is the breaking part of a Tmax T4 circuit breaker assembly and is intended to be combined with a compatible ABB protection release and other required components.

What is the current rating of the ABB T4S 250 breaking part?

The T4S 250 breaking unit has a rated uninterrupted current of 250 A.

What is the breaking capacity of the ABB T4S 250 at 400 V AC?

The T4S 250 has an ultimate short-circuit breaking capacity and service short-circuit breaking capacity of 50 kA at 400 V AC.

How many poles does the ABB 1SDA054558R1 have?

The breaking unit has a three-pole configuration and is designed for fixed installation with front terminals.

What voltages can the ABB T4S 250 breaking unit support?

The unit has a rated operational voltage of up to 690 V AC and 750 V DC, subject to the applicable pole arrangement and circuit-breaker configuration.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax circuit breaker components are used in industrial and commercial power-distribution systems worldwide, providing configurable, robust and dependable solutions for switchboard protection and electrical distribution.