Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA054540R1 T5V 400 PR221DS-I is a fixed three-pole 400 A moulded case circuit breaker with an electronic instantaneous short-circuit protection release for demanding industrial power distribution.
£4,481.06
The ABB T5V 400 PR221DS-I In=400 3P FFC, order code 1SDA054540R1, is a high-performance moulded case circuit breaker (MCCB) designed for reliable short-circuit protection in demanding industrial power-distribution systems. Part of the ABB SACE Tmax T5 series, this fixed three-pole breaker combines the T5V 400 platform with a 400 A PR221DS-I electronic trip unit.
The integrated PR221DS-I electronic release provides instantaneous short-circuit protection, making this configuration suitable for applications where overload protection is provided elsewhere or where dedicated short-circuit protection is required. Electronic trip technology provides accurate and repeatable fault detection while supporting coordination within complex electrical distribution systems.
With a 400 A rated current, three-pole configuration, fixed mounting and front terminals for copper cables, the T5V 400 is engineered for industrial switchboards, distribution assemblies and high-current feeder circuits. The V high-breaking-capacity performance level makes the breaker particularly suitable for installations with substantial prospective short-circuit currents.
Moulded case circuit breakers such as the ABB T5V 400 provide switching and fault interruption for high-current electrical distribution circuits. The PR221DS-I electronic release is dedicated to instantaneous short-circuit protection, enabling rapid disconnection when a severe fault current exceeds the configured protection threshold.
The ABB SACE Tmax T5 platform is designed for robust industrial and commercial power distribution. This T5V configuration combines electronic instantaneous protection, high short-circuit interruption performance, fixed mounting and front copper-cable terminals, making it well suited to feeder protection and switchboard applications where dependable fault clearance is essential.
| Series | SACE Tmax T5 |
|---|---|
| Order code | 1SDA054540R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame | T5 400 |
| Performance level | V |
| Rated current (In) | 400 A |
| Rated uninterrupted current (Iu) | 400 A |
| Number of poles | 3 |
| Trip unit | PR221DS-I electronic release |
| Protection function | Instantaneous short-circuit (I) |
| Mounting | Fixed |
| Terminal position | Front |
| Main connection | Front terminals for copper cables |
| Integrated earth-leakage protection | No |
| Standard | IEC 60947-2 |
The ABB 1SDA054540R1 is a SACE Tmax T5V 400 fixed three-pole moulded case circuit breaker equipped with a 400 A PR221DS-I electronic trip unit.
This T5V 400 circuit breaker has a rated current of 400 A.
The PR221DS-I electronic release provides instantaneous short-circuit protection, enabling rapid interruption when a high-level fault current is detected.
The circuit breaker has a three-pole configuration for use in suitable three-phase electrical distribution systems.
The V designation identifies the high-breaking-capacity performance version of the ABB SACE Tmax T5 circuit breaker platform, intended for demanding installations with high prospective fault currents.
The 1SDA054540R1 is a fixed-mounted circuit breaker with front terminals for copper cables, designed for integration into industrial switchboards and power-distribution assemblies.
ABB SACE Tmax moulded case circuit breakers are widely used in industrial and commercial power-distribution systems, combining robust construction, dependable fault interruption and electronic protection technology for demanding electrical installations.