1SDA054515R1 ABB T4V250 PR222DS/P-LSI In100 3P MCCB

1SDA054515R1 ABB T4V250 PR222DS/P-LSI In100 3P MCCB

ABB 1SDA054515R1 T4V250 three-pole moulded case circuit breaker with a 100 A PR222DS/P-LSI electronic trip unit, adjustable LSI protection and a rated operational voltage of 1150 V AC.

SKU: 1SDA054515R1MPN: 1SDA054515R1
Price
List Price £3,731.36 ex VAT
Your Price (ex VAT) Save 25%
£2,798.52 25% OFF
You save £932.84 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,798.52
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,798.52

Why Choose the ABB T4V250 PR222DS/P-LSI In100 3P MCCB?

The ABB T4V250 PR222DS/P-LSI In100 3P, order code 1SDA054515R1, is a high-performance moulded case circuit breaker (MCCB) designed for reliable protection and isolation in demanding high-voltage AC electrical distribution systems. As part of the ABB SACE Tmax T4 series, this fixed three-pole circuit breaker combines the robust T4V250 platform with an advanced PR222DS/P-LSI electronic trip unit.

The integrated PR222DS/P-LSI solid-state electronic trip unit provides LSI protection functions covering overload, selective short-circuit and instantaneous short-circuit conditions. Its 100 A rating and adjustable protection settings enable the breaker to be configured for effective coordination and protection of electrical circuits and connected equipment.

Designed for demanding installations with an operational voltage up to 1150 V AC, the T4V250 is particularly suited to specialist industrial power distribution systems. Its fixed three-pole construction and front terminals for copper cables provide straightforward integration into switchboards, distribution panels and industrial electrical assemblies.

Key Advantages

  • High-performance ABB SACE Tmax T4 moulded case circuit breaker.
  • 100 A rated current for industrial circuit protection.
  • Three-pole configuration for three-phase AC electrical systems.
  • Advanced PR222DS/P-LSI electronic trip unit.
  • LSI protection functions provide overload and short-circuit protection.
  • Adjustable overload protection range of 40–100 A.
  • Adjustable short-time delayed short-circuit protection range of 60–1000 A.
  • Adjustable instantaneous short-circuit protection range of 150–1200 A.
  • Designed for applications up to 1150 V AC.
  • Fixed installation with front terminals for copper cables.

Key Features

  • ABB SACE Tmax T4 series.
  • T4V250 frame.
  • 100 A trip unit rated current.
  • Three-pole (3P) configuration.
  • PR222DS/P-LSI electronic trip unit.
  • Long-time overload protection with adjustable 40–100 A setting.
  • Short-time delayed short-circuit adjustment from 60–1000 A.
  • Instantaneous short-circuit adjustment from 150–1200 A.
  • 1150 V AC rated operational voltage.
  • 20 kA Icu at 1000 V AC.
  • 12 kA Icu at 1150 V AC.
  • Fixed construction with front terminals for copper cables.

Advanced Electronic Protection for Industrial Power Systems

Moulded case circuit breakers such as the ABB T4V250 protect electrical circuits and connected equipment against potentially damaging overload and short-circuit conditions. The PR222DS/P-LSI electronic trip unit provides adjustable long-time, short-time and instantaneous protection, enabling more precise protection settings and coordination than conventional fixed protection devices.

The Tmax T4 platform is engineered for industrial electrical distribution applications requiring dependable switching, high breaking performance and configurable circuit protection. With its 1150 V AC capability, fixed construction and electronic LSI protection, the 1SDA054515R1 is particularly suitable for specialist high-voltage AC distribution systems and industrial switchboards.

Typical Applications

  • Industrial electrical power distribution systems.
  • High-voltage AC distribution up to 1150 V AC.
  • Electrical switchboards and distribution panels.
  • Industrial machinery and process equipment.
  • Power generation and energy infrastructure.
  • Renewable energy installations.
  • Industrial plant electrical protection.
  • OEM electrical panels and control systems.

Technical Specifications

Series SACE Tmax T4
ABB product group 310511-T-Max T4 - T8
Order code 1SDA054515R1
Product type Moulded case circuit breaker (MCCB)
Frame T4V250
Trip unit rated current 100 A
Trip unit PR222DS/P-LSI electronic
Protection functions LSI
Overload release adjustment 40–100 A
Short-time delayed short-circuit adjustment 60–1000 A
Instantaneous short-circuit adjustment 150–1200 A
Number of poles 3
Rated operational voltage 1150 V AC
Ultimate breaking capacity (Icu) at 1000 V AC 20 kA
Ultimate breaking capacity (Icu) at 1150 V AC 12 kA
Service breaking capacity (Ics) at 1000 V AC 12 kA
Service breaking capacity (Ics) at 1150 V AC 6 kA
Construction Fixed built-in device
Main circuit connection Front terminals for copper cables
Protection unit Integrated
Integrated earth-fault protection No
Dimensions (H × W × D) 205 × 105 × 103.5 mm
Weight approx. 3.5 kg
Mechanical durability 20,000 cycles
Electrical durability 8,000 cycles
EAN 8015644556174

Frequently Asked Questions

What is the ABB 1SDA054515R1 used for?

The ABB 1SDA054515R1 is a three-pole moulded case circuit breaker designed to provide adjustable overload and short-circuit protection in demanding industrial AC electrical distribution systems.

What is the rated current of the ABB T4V250 PR222DS/P-LSI?

The circuit breaker is supplied with a 100 A PR222DS/P-LSI electronic trip unit, with overload protection adjustable from 40–100 A.

What protection does the PR222DS/P-LSI trip unit provide?

The PR222DS/P-LSI provides LSI protection, comprising long-time overload, short-time selective short-circuit and instantaneous short-circuit protection functions.

How many poles does the ABB 1SDA054515R1 have?

The 1SDA054515R1 is a three-pole (3P) moulded case circuit breaker designed for AC electrical distribution applications.

What voltage is the ABB T4V250 1SDA054515R1 designed for?

This T4V250 configuration is designed for operation at up to 1150 V AC, with an ultimate short-circuit breaking capacity of 12 kA at 1150 V AC.

Trusted ABB Circuit Protection

ABB SACE Tmax moulded case circuit breakers provide dependable switching and circuit protection for industrial electrical distribution systems, with electronic protection technology enabling flexible settings and effective coordination in demanding applications.