1SDA054423R1 ABB T5L630 PR222DS/P-LSIG 630 A 3-Pole MCCB

1SDA054423R1 ABB T5L630 PR222DS/P-LSIG 630 A 3-Pole MCCB

ABB 1SDA054423R1 SACE Tmax T5L630 fixed three-pole 630 A moulded case circuit breaker with PR222DS/P-LSIG electronic trip unit providing adjustable LSIG overload, short-circuit and earth-fault protection.

SKU: 1SDA054423R1MPN: 1SDA054423R1
Price
List Price £7,238.56 ex VAT
Your Price (ex VAT) Save 25%
£5,428.92 25% OFF
You save £1,809.64 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,428.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,428.92

Why Choose the ABB T5L630 PR222DS/P-LSIG 630 A 1SDA054423R1 Circuit Breaker?

The ABB 1SDA054423R1 is a high-performance SACE Tmax T5L 630 moulded case circuit breaker (MCCB) designed for protection and isolation in demanding low-voltage power distribution systems. Configured as a fixed three-pole breaker with front terminals, it combines a 630 A rated current with ABB's PR222DS/P-LSIG electronic trip unit.

Part of the established ABB SACE Tmax T5 series, the T5L630 provides comprehensive electronic LSIG protection, covering long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault conditions. This combination supports flexible protection coordination across industrial, commercial and infrastructure distribution networks.

The PR222DS/P-LSIG release provides a 252–630 A long-time overload adjustment range and short-circuit protection adjustable across a 945–5,985 A range. Combined with the high-breaking-performance T5L platform, the 1SDA054423R1 provides robust protection for substantial three-phase feeders and distribution circuits where high prospective fault currents and earth-fault protection must be addressed.

Key Advantages

  • High-performance ABB SACE Tmax T5L 630 moulded case circuit breaker.
  • 630 A rated current for substantial low-voltage distribution circuits.
  • Three-pole configuration for three-phase electrical systems.
  • PR222DS/P-LSIG electronic trip unit for flexible electronic protection.
  • LSIG protection covers overload, short-time, instantaneous and earth-fault conditions.
  • 252–630 A long-time overload adjustment range supports protection coordination.
  • High T5L interruption-performance level for demanding prospective fault currents.
  • Fixed mounting with front terminals for practical switchboard integration.

Key Features

  • ABB SACE Tmax T5L 630 circuit breaker platform.
  • 630 A rated current.
  • 3-pole construction.
  • PR222DS/P-LSIG electronic release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Electronic earth-fault protection.
  • Long-time adjustment from 252–630 A.
  • Short-circuit protection adjustment across 945–5,985 A.
  • Fixed circuit breaker configuration with front terminals.

Reliable Circuit Protection for Power Distribution

The ABB SACE Tmax T5L platform is designed for demanding low-voltage power distribution applications where substantial current capacity, strong interruption performance and flexible electronic protection are required. With a 630 A frame and rated current, the 1SDA054423R1 is suited to high-current feeders and distribution circuits in industrial, commercial and infrastructure installations.

Its PR222DS/P-LSIG electronic trip unit provides protection against sustained overloads, delayed and instantaneous short-circuit faults and earth faults. This LSIG functionality allows the breaker to address multiple fault conditions while supporting effective coordination with cables, downstream protective devices and connected electrical equipment.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and sub-main distribution switchboards.
  • High-current three-phase feeder circuits.
  • Manufacturing and process installations.
  • Commercial and infrastructure power distribution.
  • Applications requiring electronic earth-fault protection.

Technical Specifications

Series SACE Tmax T5
ABB order code 1SDA054423R1
Product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker (MCCB)
Frame T5 630
Performance level L
Rated current (In) 630 A
Number of poles 3
Trip unit PR222DS/P-LSIG electronic release
Protection functions LSIG — long-time, short-time, instantaneous and earth fault
Long-time overload adjustment 252–630 A
Short-circuit protection adjustment 945–5,985 A
Mounting type Fixed
Terminal type Front terminals

Frequently Asked Questions

What is the ABB 1SDA054423R1 used for?

The ABB 1SDA054423R1 is a 630 A three-pole electronic moulded case circuit breaker designed to protect and isolate demanding low-voltage distribution circuits against overload, short-circuit and earth-fault conditions.

What is the current rating of the ABB T5L630 1SDA054423R1?

The circuit breaker has a rated current of 630 A and is based on the ABB SACE Tmax T5L 630 platform.

What protection does the PR222DS/P-LSIG trip unit provide?

The PR222DS/P-LSIG provides LSIG protection comprising long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection.

What is the overload adjustment range of the ABB 1SDA054423R1?

The PR222DS/P-LSIG electronic release provides a long-time overload adjustment range of 252–630 A, allowing the protection threshold to be matched to the requirements of the protected circuit.

How is the ABB 1SDA054423R1 installed?

The 1SDA054423R1 is a fixed three-pole circuit breaker with front terminals, designed for integration into low-voltage switchboards and electrical distribution panels.

Trusted Protection from ABB

ABB SACE Tmax moulded case circuit breakers combine high interruption performance with flexible electronic protection, providing dependable overload, short-circuit and earth-fault protection for demanding industrial and commercial low-voltage distribution systems.