1sda054398r1  t5n 630 pr222ds/p-lsi in=630 3 pole abb mccb

1sda054398r1 t5n 630 pr222ds/p-lsi in=630 3 pole abb mccb

ABB 1SDA054398R1 Tmax T5N 630 moulded case circuit breaker with PR222DS/P-LSI electronic trip unit, 630 A rated current, three-pole configuration and fixed front terminals for industrial power distribution.

SKU: 1SDA054398R1Alt SKU: T5N 630 PR222DS/P-LSI In=630 3p F FMPN: 1SDA054398R1
Price
List Price £4,449.88 ex VAT
Your Price (ex VAT) Save 25%
£3,337.41 25% OFF
You save £1,112.47 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,337.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,337.41

Why Choose the ABB 1SDA054398R1 Tmax T5N 630 MCCB?

The ABB 1SDA054398R1 is a high-performance Tmax T5N moulded case circuit breaker (MCCB) designed for reliable protection in industrial power distribution systems, electrical switchboards and OEM control panels. Featuring a 630 A rated current, three-pole configuration and fixed front terminal design, this MCCB provides dependable protection for demanding low voltage electrical installations.

As part of the proven ABB SACE Tmax T series, this circuit breaker combines robust construction, compact dimensions and advanced electronic protection. The integrated PR222DS/P-LSI solid-state release provides long-time, short-time and instantaneous protection functions, helping improve selectivity, safety and reliability across industrial electrical networks.

With a rated operational voltage of up to 690 V AC, rated uninterrupted current of 630 A and compliance with IEC 60947, the ABB 1SDA054398R1 is suitable for panel builders, electrical contractors and maintenance engineers requiring dependable MCCB protection in three-phase commercial and industrial systems.

Key Advantages

  • Reliable ABB Tmax T5N moulded case circuit breaker for industrial protection.
  • 630 A rated current for high-load power distribution systems.
  • Three-pole configuration for three-phase electrical installations.
  • PR222DS/P-LSI electronic trip unit for advanced circuit protection.
  • Fixed front terminal design for switchboard and panel installation.
  • Designed to meet IEC 60947 low voltage circuit breaker standards.

Key Features

  • ABB SACE Tmax T5N series.
  • Product code: 1SDA054398R1.
  • Rated current: 630 A.
  • Three-pole moulded case circuit breaker.
  • PR222DS/P-LSI solid-state electronic release.
  • Rated operational voltage: up to 690 V AC.
  • Rated insulation voltage: 1000 V.
  • Compact fixed mounting design with front terminals.

Advanced Protection for High-Load Power Systems

The ABB Tmax T5N range is engineered to protect low voltage electrical installations from overload and short circuit conditions while supporting continuity of service. The PR222DS/P-LSI electronic release provides adjustable protection functions, making it suitable for applications where selectivity, reliability and accurate tripping performance are important.

The 1SDA054398R1 offers a strong combination of electrical performance, compact installation and durable ABB construction. Its three-pole design makes it suitable for three-phase distribution systems requiring reliable circuit protection in demanding industrial and commercial environments.

Typical Applications

  • Industrial switchboards and distribution panels.
  • Motor control centres and machinery panels.
  • Commercial building electrical distribution.
  • Manufacturing and processing facilities.
  • OEM electrical control systems.
  • Low voltage power protection applications.

Technical Specifications

Tick the specs you need, then view products that match.

Current 630 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Breaking Capacity 36 kA
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T5N 630 PR222DS/P-LSI In=630 3P F F
Product code 1SDA054398R1
EAN 8015644554965
Product type Moulded Case Circuit Breaker (MCCB)
Rated current (In) 630 A
Rated uninterrupted current (Iu) 630 A
Number of poles 3
Trip unit PR222DS/P-LSI electronic release
Release type Electronic
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated service breaking capacity (Ics) 36 kA at 400 V AC
Rated ultimate breaking capacity (Icu) 36 kA at 400 V AC
Short-time withstand current (Icw) 5 kA for 1 second
Short-circuit performance level N
Power loss 41 W per pole at rated operating conditions
Terminal type Fixed front terminals
Standards IEC 60947
Dimensions (H × W × D) approx. 205 × 140 × 103.5 mm
Weight approx. 5.1 kg

Frequently Asked Questions

What is the ABB 1SDA054398R1 used for?

It is used to protect low voltage three-phase electrical circuits, switchboards and industrial distribution systems against overload and short circuit conditions.

What is the rated current of this MCCB?

The ABB 1SDA054398R1 has a 630 A rated current.

How many poles does this circuit breaker have?

This model has a three-pole (3P) configuration for three-phase electrical systems.

What trip unit is fitted to the ABB 1SDA054398R1?

It is fitted with a PR222DS/P-LSI electronic trip unit, providing long-time, short-time and instantaneous protection functions.

Where is this MCCB typically installed?

It is commonly installed in electrical switchboards, power distribution panels, motor control centres and OEM machinery control panels.

Trusted by Industry Worldwide

ABB SACE Tmax moulded case circuit breakers are trusted by electrical engineers, panel builders and industrial operators worldwide for reliable circuit protection, high breaking performance and long-term dependability.