1SDA054389R1 ABB T5V400 PR221DS-LS/I 400 A 4-Pole MCCB

1SDA054389R1 ABB T5V400 PR221DS-LS/I 400 A 4-Pole MCCB

ABB 1SDA054389R1 SACE Tmax T5V400 fixed four-pole 400 A moulded case circuit breaker with PR221DS-LS/I electronic trip unit for overload and short-circuit protection in demanding low-voltage distribution systems.

SKU: 1SDA054389R1Alt SKU: T5V400R400MPN: 1SDA054389R1
Price
List Price £5,824.74 ex VAT
Your Price (ex VAT) Save 25%
£4,368.56 25% OFF
You save £1,456.19 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,368.56
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,368.56

Why Choose the ABB T5V400 PR221DS-LS/I 400 A 1SDA054389R1 Circuit Breaker?

The ABB 1SDA054389R1 is a high-performance SACE Tmax T5V 400 moulded case circuit breaker (MCCB) designed for protection and isolation in demanding low-voltage electrical distribution systems. Configured as a fixed four-pole breaker with front terminals, it combines a 400 A rated current with ABB's PR221DS-LS/I electronic trip unit.

Part of the ABB SACE Tmax T5 series, the T5V400 provides electronic LS/I protection for overload and short-circuit conditions. The PR221DS release enables protection characteristics to be adapted to the electrical installation, supporting effective coordination with cables, connected equipment and other protective devices.

The T5V performance level is engineered for systems with exceptionally high prospective fault currents. With a 400 A electronic release, four-pole construction, fixed mounting and front terminals, the 1SDA054389R1 is particularly well suited to industrial switchboards, commercial distribution systems and other high-demand low-voltage installations.

Key Advantages

  • High-performance ABB SACE Tmax T5V 400 moulded case circuit breaker.
  • 400 A rated current for substantial industrial and commercial loads.
  • Four-pole configuration for multipole low-voltage distribution systems.
  • PR221DS-LS/I electronic trip unit for dependable electronic protection.
  • Provides long-time overload and short-circuit protection functions.
  • T5V high-breaking-performance design for demanding fault-current conditions.
  • Fixed construction for permanent switchboard installation.
  • Front terminals support practical integration into electrical distribution assemblies.

Key Features

  • ABB SACE Tmax T5V 400 circuit breaker platform.
  • 400 A rated current.
  • 400 A frame size.
  • 4-pole construction.
  • PR221DS-LS/I electronic release.
  • Long-time overload protection.
  • Short-circuit protection.
  • High T5V interruption-performance level.
  • Fixed mounting configuration.
  • Front-terminal connection arrangement.

Reliable Circuit Protection for Power Distribution

The ABB SACE Tmax T5V platform is designed for demanding low-voltage power distribution applications where dependable electronic protection and high interruption performance are required. With its 400 A frame and 400 A PR221DS-LS/I release, the 1SDA054389R1 is suited to protecting substantial feeders and distribution circuits in industrial and commercial installations.

The electronic trip unit provides protection against sustained overloads and short-circuit faults, helping safeguard conductors, switchgear and connected equipment. Its four-pole configuration, fixed installation format and front terminals provide a practical arrangement for incorporation into low-voltage switchboards and distribution panels.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main and sub-distribution switchboards.
  • Three-phase four-wire electrical distribution panels.
  • Manufacturing and process installations.
  • Commercial and infrastructure power distribution.
  • Installations with high prospective short-circuit currents.

Technical Specifications

Series SACE Tmax T5
ABB order code 1SDA054389R1
Product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker (MCCB)
Frame T5 400
Performance level V
Rated current (In) 400 A
Number of poles 4
Trip unit PR221DS-LS/I electronic release
Protection functions LS/I — long-time overload and short-circuit protection
Mounting type Fixed
Terminal type Front terminals

Frequently Asked Questions

What is the ABB 1SDA054389R1 used for?

The ABB 1SDA054389R1 is a 400 A four-pole electronic moulded case circuit breaker designed to protect and isolate demanding low-voltage electrical distribution circuits against overload and short-circuit conditions.

What is the current rating of the ABB T5V400 1SDA054389R1?

The ABB 1SDA054389R1 has a rated current of 400 A and is built on the SACE Tmax T5V 400 frame.

What protection does the PR221DS-LS/I trip unit provide?

The PR221DS-LS/I is an electronic trip unit providing long-time overload protection together with short-circuit protection for low-voltage electrical distribution circuits.

How many poles does the ABB 1SDA054389R1 have?

The 1SDA054389R1 is a four-pole MCCB, making it suitable for applications requiring four-pole switching and protection within low-voltage distribution systems.

How is the ABB 1SDA054389R1 installed?

The 1SDA054389R1 is a fixed circuit breaker with front terminals, designed for integration into low-voltage switchboards and electrical distribution panels.

Trusted Protection from ABB

ABB SACE Tmax moulded case circuit breakers combine robust interruption performance with dependable electronic protection, providing effective circuit protection for demanding industrial and commercial low-voltage distribution systems.