1sda054296r1  t4n 250ma 80-1120 3 pole abb mccb

1sda054296r1 t4n 250ma 80-1120 3 pole abb mccb

ABB 1SDA054296R1 Tmax T4N 250 three-pole moulded case circuit breaker with magnetic-only MA release, 80 A rated current, 480-1120 A instantaneous setting, fixed version and front terminals for low-voltage short-circuit protection.

SKU: 1SDA054296R1Alt SKU: T4N 250MA 80-1120 3p F FMPN: 1SDA054296R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA054296R1 Tmax T4N Moulded Case Circuit Breaker?

The ABB 1SDA054296R1 is a reliable Tmax T4N moulded case circuit breaker (MCCB) designed for low-voltage circuit protection in industrial and commercial electrical distribution systems. As part of the proven ABB SACE Tmax T4N 250 series, this fixed three-pole circuit breaker is suitable for switchboards, control panels, OEM machinery and power distribution assemblies.

This model features a magnetic-only MA release with an 80 A rated current and an instantaneous magnetic setting range of 480–1120 A. The magnetic release is designed for short-circuit protection, making the breaker well suited to applications where overload protection is handled separately, such as motor protection systems with external thermal overload relays.

With its fixed three-pole construction, front terminals and compact Tmax T4 frame, the ABB 1SDA054296R1 provides dependable installation flexibility and robust fault protection for demanding low-voltage electrical systems.

Key Advantages

  • High-quality ABB Tmax T4N moulded case circuit breaker.
  • 80 A rated current for low-voltage distribution and motor protection systems.
  • Magnetic-only MA release for short-circuit protection.
  • Instantaneous magnetic setting from 480–1120 A.
  • Three-pole fixed design with front terminals.
  • Ideal where overload protection is provided by a separate protection device.

Key Features

  • ABB SACE Tmax T4N 250 series.
  • Product code: 1SDA054296R1.
  • Rated current: 80 A.
  • Three-pole (3P) moulded case circuit breaker.
  • Magnetic-only MA trip unit.
  • Instantaneous setting: 480–1120 A.
  • Fixed breaker version.
  • Front terminal connection.
  • Designed for low-voltage switchboards, control panels and motor circuits.

Reliable Short-Circuit Protection for Low-Voltage Systems

Moulded case circuit breakers help protect electrical installations by disconnecting circuits during fault conditions. In magnetic-only versions such as the ABB 1SDA054296R1, the trip unit is focused on short-circuit protection, allowing overload protection to be managed by a separate device where required.

This makes the ABB 1SDA054296R1 particularly suitable for motor feeder applications, machinery panels and coordinated protection systems where separate overload relays are used alongside the MCCB.

Typical Applications

  • Motor feeder protection systems.
  • Industrial electrical distribution boards.
  • OEM machinery and automation equipment.
  • Control panels and switchgear assemblies.
  • Motor control centres.
  • Low-voltage short-circuit protection applications.

Technical Specifications

Tick the specs you need, then view products that match.

Current 80 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Magnetic only
Manufacturer ABB
Series SACE Tmax T4N
Model T4N 250 MA 80-1120 3P F F
Product code 1SDA054296R1
Product type Moulded Case Circuit Breaker
Frame size T4N 250
Number of poles 3
Rated current 80 A
Release type Magnetic only
Trip unit MA
Instantaneous setting 480–1120 A
Version Fixed
Terminal connection Front terminals
Rated operational voltage Up to 690 V AC
Mounting type Panel / switchboard mounting
Dimensions (H × W × D) Approx. 205 × 105 × 103.5 mm
Weight Approx. 2.35 kg
Product family ABB SACE Tmax T moulded case circuit breakers

Frequently Asked Questions

What is the ABB 1SDA054296R1 used for?

The ABB 1SDA054296R1 is used for short-circuit protection in low-voltage electrical systems, particularly where overload protection is provided separately.

How many poles does this circuit breaker have?

This model is a three-pole moulded case circuit breaker, suitable for three-phase circuit protection applications.

What type of trip unit does the ABB 1SDA054296R1 use?

It uses a magnetic-only MA release, which provides short-circuit protection without integrated thermal overload protection.

What is the rated current of this MCCB?

The ABB 1SDA054296R1 has a rated current of 80 A with an instantaneous magnetic setting range of 480–1120 A.

Where is this MCCB typically installed?

It is typically installed in motor feeder panels, switchboards, control panels, OEM machinery and low-voltage electrical assemblies.

Trusted by Electrical Professionals Worldwide

ABB Tmax moulded case circuit breakers are widely specified by panel builders, electrical contractors and industrial maintenance teams for dependable protection, compact installation and long-term reliability in low-voltage power distribution and motor protection systems.