1sda054277r1  t4s 250 tma 200-2000 4 pole abb mccb

1sda054277r1 t4s 250 tma 200-2000 4 pole abb mccb

ABB 1SDA054277R1 SACE Tmax T4S 200 A four-pole moulded case circuit breaker with TMA thermomagnetic release, fully rated neutral and fixed front terminals for low voltage power distribution.

SKU: 1SDA054277R1Alt SKU: T4S 250 TMA 200-20MPN: 1SDA054277R1
Price
List Price £2,065.81 ex VAT
Your Price (ex VAT) Save 25%
£1,549.36 25% OFF
You save £516.45 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,549.36
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,549.36

Why Choose the ABB 1SDA054277R1 Tmax T4S Moulded Case Circuit Breaker?

The ABB 1SDA054277R1 is a high-performance Tmax T4S moulded case circuit breaker (MCCB) engineered to provide dependable protection for low voltage electrical distribution systems. As part of the trusted ABB SACE Tmax T series, this four-pole circuit breaker delivers reliable overload and short-circuit protection for industrial, commercial and OEM electrical installations.

Fitted with a TMA thermomagnetic trip unit, the breaker combines thermal overload protection with adjustable magnetic short-circuit protection. Its fully rated neutral (InN = 100% In) configuration makes it particularly suitable for four-pole systems where full neutral protection and isolation are required.

With a 200 A rated current, 250 A frame size, fixed front terminals and rated operation up to 690 V AC, the ABB 1SDA054277R1 provides dependable protection for switchboards, distribution panels, motor control centres and industrial machinery.

Key Advantages

  • Reliable ABB SACE Tmax T4S moulded case circuit breaker.
  • 200 A rated current for demanding industrial distribution systems.
  • Four-pole design with fully rated neutral.
  • TMA thermomagnetic trip unit for overload and short-circuit protection.
  • 50 kA breaking capacity at 400 V AC.
  • Fixed front terminal design simplifies switchboard installation.

Key Features

  • ABB SACE Tmax T series.
  • T4S 250 frame size.
  • 200 A rated current.
  • Four-pole MCCB configuration.
  • Fully rated neutral: InN = 100% In.
  • TMA thermomagnetic release.
  • Adjustable magnetic setting from 1000 to 2000 A.
  • Fixed version with front terminal connections.

Reliable Protection for Low Voltage Power Distribution

The ABB Tmax T4S range is designed to protect electrical installations against overloads and short-circuit faults while maintaining dependable operation under demanding industrial conditions. Rapid fault interruption helps reduce equipment damage, improve operational safety and minimise downtime.

Its fully rated neutral design makes this breaker particularly suitable for modern four-pole distribution systems where neutral conductors require the same level of protection as phase conductors, including commercial buildings, industrial facilities and OEM machinery.

Typical Applications

  • Industrial low voltage power distribution.
  • Electrical switchboards and distribution panels.
  • Commercial building electrical installations.
  • Motor control centres.
  • OEM machinery and automation systems.
  • Feeder and sub-distribution circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Current 200 A
Phase Three Phase
Poles 4-pole
Device Type MCCB
Breaking Capacity 50 kA
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax T
Model T4S 250 TMA 200-2000 4P F F InN=100%In
Product code 1SDA054277R1
Product type Moulded Case Circuit Breaker
Rated current (In) 200 A
Rated uninterrupted current (Iu) 250 A
Number of poles 4
Neutral rating Fully rated neutral, InN = 100% In
Trip unit TMA thermomagnetic release
Magnetic adjustment range 1000-2000 A
Rated operational voltage 690 V AC / 750 V DC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated ultimate breaking capacity (Icu) 50 kA at 400 V AC
Rated service breaking capacity (Ics) 50 kA at 400 V AC
Terminal type Fixed front terminals
Standards IEC 60947
Dimensions (H × W × D) approx. 205 × 140 × 103.5 mm
Weight approx. 3.05 kg

Frequently Asked Questions

What is the ABB 1SDA054277R1 used for?

This moulded case circuit breaker protects low voltage electrical systems against overloads and short-circuit faults in industrial and commercial installations.

What is the rated current of this breaker?

The ABB 1SDA054277R1 has a 200 A rated current.

How many poles does this MCCB have?

This model is a four-pole moulded case circuit breaker with a fully rated neutral.

What does InN = 100% In mean?

It means the neutral pole is rated at the same current as the phase poles, providing complete neutral protection and isolation.

What type of trip unit is fitted?

The breaker is fitted with a TMA thermomagnetic release providing thermal overload protection together with adjustable magnetic short-circuit protection.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are trusted worldwide for dependable circuit protection, high performance and long service life across industrial, commercial and OEM electrical installations.