1SDA054256R1 ABB T4V 250 TMA 100-1000 100 A 4-Pole MCCB

1SDA054256R1 ABB T4V 250 TMA 100-1000 100 A 4-Pole MCCB

ABB 1SDA054256R1 T4V 250 TMA 100-1000 is a 100 A four-pole fixed moulded case circuit breaker with front terminals, adjustable thermomagnetic protection and a 200 kA ultimate short-circuit breaking capacity at 380–415 V AC.

SKU: 1SDA054256R1MPN: 1SDA054256R1
Price
List Price £2,000.54 ex VAT
Your Price (ex VAT) Save 25%
£1,500.41 25% OFF
You save £500.14 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,500.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,500.41

Why Choose the ABB T4V 250 TMA 100-1000 Circuit Breaker?

The ABB T4V 250 TMA 100-1000, order code 1SDA054256R1, is a high-performance 4-pole moulded case circuit breaker (MCCB) designed for protection and switching in low-voltage electrical distribution systems. As part of the proven ABB Tmax T4 series, it combines a 100 A rated current with a TMA thermomagnetic trip unit for dependable protection of industrial and commercial power circuits.

The TMA thermomagnetic trip unit provides adjustable thermal overload and magnetic short-circuit protection without requiring an external power supply. Thermal protection is adjustable from 0.7 to 1 times the rated current, while magnetic protection is adjustable from 5 to 10 times the rated current, providing a magnetic trip adjustment range of 500–1000 A.

With a rated current of 100 A and an ultimate short-circuit breaking capacity of 200 kA at 380–415 V AC, the T4V 250 provides exceptionally high fault-current interruption capability. This configuration is a 4-pole fixed circuit breaker with front terminals, making it suitable for permanent installation in switchboards, distribution panels and demanding industrial electrical assemblies.

Key Advantages

  • High-performance ABB Tmax T4 moulded case circuit breaker.
  • 100 A rated current for industrial and commercial distribution circuits.
  • 200 kA ultimate breaking capacity at 380–415 V AC for installations with very high prospective fault currents.
  • TMA thermomagnetic release provides overload and short-circuit protection.
  • Adjustable thermal protection from 0.7–1 × In.
  • Adjustable magnetic protection from 5–10 × In.
  • 500–1000 A magnetic trip adjustment range.
  • 4-pole fixed construction with front terminals for straightforward switchboard integration.

Key Features

  • ABB Tmax T4V 250 circuit breaker.
  • 100 A rated current.
  • 4-pole configuration.
  • Fixed mounting execution.
  • Front terminals.
  • TMA thermomagnetic trip unit.
  • Adjustable thermal overload protection.
  • 500–1000 A adjustable magnetic short-circuit protection.
  • 200 kA Icu at 380–415 V AC.
  • Designed for demanding low-voltage electrical distribution applications.

High-Performance Thermomagnetic Circuit Protection

Moulded case circuit breakers such as the ABB Tmax T4 protect electrical installations by automatically interrupting excessive currents caused by overloads and short circuits. The T4V performance level combines compact construction with very high short-circuit interruption capability, making it particularly suitable for demanding industrial and commercial distribution systems.

The TMA release combines adjustable thermal overload protection with adjustable magnetic short-circuit protection. This enables the protection characteristics to be coordinated with the connected circuit while retaining the simplicity and reliability of a self-powered thermomagnetic protection system.

Typical Applications

  • Industrial low-voltage distribution boards.
  • Main and feeder circuit protection.
  • Manufacturing and process plant electrical systems.
  • Commercial and infrastructure switchboards.
  • Machinery and automation power distribution.
  • Four-pole circuits requiring adjustable thermomagnetic protection.
  • Installations with very high prospective short-circuit currents.

Technical Specifications

Series Tmax T4
ABB order code 1SDA054256R1
Product type Moulded case circuit breaker (MCCB)
Frame T4
Performance level V
Rated current (In) 100 A
Trip unit TMA thermomagnetic
Thermal protection setting 0.7–1 × In
Magnetic protection setting 5–10 × In
Magnetic trip adjustment range 500–1000 A
Number of poles 4
Ultimate short-circuit breaking capacity (Icu) at 220–230 V AC 200 kA
Ultimate short-circuit breaking capacity (Icu) at 380–415 V AC 200 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 180 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 80 kA
Mounting Fixed
Terminal arrangement Front terminals
Dimensions (H × W × D) 205 × 130 × 103.5 mm
Weight approx. 3.84 kg

Frequently Asked Questions

What is the ABB 1SDA054256R1?

The ABB 1SDA054256R1 is a Tmax T4V 250 fixed 4-pole moulded case circuit breaker with front terminals and a 100 A TMA thermomagnetic trip unit.

What is the rated current of this circuit breaker?

This T4V 250 configuration has a rated current of 100 A.

What protection does the TMA trip unit provide?

The TMA trip unit provides adjustable thermal overload and magnetic short-circuit protection, with this model offering a magnetic adjustment range of 500–1000 A.

What is the breaking capacity of the ABB T4V 250?

This configuration provides an ultimate short-circuit breaking capacity of 200 kA at 380–415 V AC, with the available breaking capacity varying according to operating voltage.

Where is the ABB T4V 250 TMA typically used?

It is typically installed in industrial and commercial low-voltage switchboards, machinery and distribution panels requiring 4-pole adjustable thermomagnetic protection and very high short-circuit breaking performance.

Trusted ABB Circuit Protection

ABB Tmax moulded case circuit breakers are widely used in industrial and commercial electrical distribution systems, providing dependable switching, adjustable thermomagnetic protection and high short-circuit performance for demanding low-voltage installations.