ABB 1SDA054225R1 T4L 250 TMD is a 20 A three-pole fixed moulded case circuit breaker with a thermomagnetic trip unit and high short-circuit breaking capacity for industrial and commercial power distribution.
£1,184.35
The ABB 1SDA054225R1 is a high-performance SACE Tmax T4L moulded case circuit breaker (MCCB) designed for reliable protection and switching in industrial and commercial low-voltage electrical distribution systems. Part of the proven ABB SACE Tmax T series, this three-pole circuit breaker combines a compact T4 frame with a thermomagnetic TMD trip unit for dependable overload and short-circuit protection.
The T4L configuration provides a high short-circuit breaking capacity for demanding power distribution applications. Its TMD thermomagnetic release provides adjustable thermal overload protection together with fixed magnetic short-circuit protection, helping safeguard cables, switchgear and downstream electrical equipment against damaging overcurrents.
With a 20 A rated current, three-pole construction and fixed installation with front terminals, the 1SDA054225R1 is suitable for straightforward integration into switchboards and distribution panels. The T4L performance level provides an ultimate short-circuit breaking capacity of up to 120 kA at 380–415 V AC, making this MCCB particularly suitable for installations where high prospective fault currents are present.
Moulded case circuit breakers such as the ABB SACE Tmax T4L protect electrical distribution circuits against overloads and short circuits while also providing a convenient means of circuit isolation and switching. The TMD trip unit combines thermal overload protection with magnetic short-circuit protection, providing dependable protection without requiring a separate electronic trip system.
The T4L's high short-circuit performance makes it particularly well suited to industrial installations where prospective fault currents can be substantial. Its compact fixed configuration and front terminals simplify installation in switchboards, control panels and power distribution assemblies while maintaining the protection performance expected from the ABB SACE Tmax range.
| Series | SACE Tmax T |
|---|---|
| ABB order code | 1SDA054225R1 |
| Product group | 310511-T-Max T4 - T8 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame / subtype | T4 |
| Performance level | L |
| Rated current | 20 A |
| Number of poles | 3P |
| Trip unit | TMD thermomagnetic |
| Thermal protection | Adjustable, approximately 0.7–1 × In |
| Magnetic protection | Fixed |
| Rated operational voltage | up to 690 V AC / 750 V DC |
| Rated insulation voltage (Ui) | 1,000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Ultimate breaking capacity (Icu) at 220/230 V AC | 200 kA |
| Ultimate breaking capacity (Icu) at 380/400/415 V AC | 120 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 100 kA |
| Ultimate breaking capacity (Icu) at 500 V AC | 85 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 70 kA |
| DC breaking capacity at 250 V DC | 100 kA with 2 poles in series |
| DC breaking capacity at 500 V DC | 70 kA with 2 poles in series |
| DC breaking capacity at 750 V DC | 50 kA with 3 poles in series |
| Mounting type | Fixed |
| Terminal type | Front terminals |
| Power loss | 3.6 W per pole at rated operating conditions |
| Mechanical durability | 20,000 operating cycles |
| Electrical durability | 8,000 operating cycles |
| Dimensions (H × W × D) | 205 × 105 × 103.5 mm |
| Standards | IEC |
| EAN | 8015644553227 |
The ABB 1SDA054225R1 is a three-pole moulded case circuit breaker used to provide overload and short-circuit protection in industrial and commercial low-voltage power distribution systems.
The circuit breaker has a 20 A rated current and uses an ABB TMD thermomagnetic trip unit.
The T4L circuit breaker provides an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, with breaking capacity varying according to the operating voltage.
The 1SDA054225R1 uses a TMD thermomagnetic trip unit, combining adjustable thermal overload protection with fixed magnetic short-circuit protection.
This model is a fixed three-pole circuit breaker with front terminals, designed for installation in electrical switchboards, distribution panels and similar low-voltage assemblies.
ABB SACE Tmax moulded case circuit breakers are engineered for dependable circuit protection and switching in low-voltage power distribution systems, combining compact construction, flexible protection and high short-circuit performance for industrial and commercial installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.