1SDA054116R1 ABB T4V250 PR222DS/P-LSIG 250 A 4-Pole MCCB

1SDA054116R1 ABB T4V250 PR222DS/P-LSIG 250 A 4-Pole MCCB

ABB 1SDA054116R1 SACE Tmax T4V250 fixed four-pole 250 A moulded case circuit breaker with PR222DS/P-LSIG electronic trip unit for high-performance low-voltage circuit protection.

SKU: 1SDA054116R1MPN: 1SDA054116R1
Price
List Price £5,763.49 ex VAT
Your Price (ex VAT) Save 25%
£4,322.62 25% OFF
You save £1,440.87 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,322.62
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,322.62

Why Choose the ABB T4V250 PR222DS/P-LSIG 1SDA054116R1 Circuit Breaker?

The ABB 1SDA054116R1 is a high-performance SACE Tmax T4V 250 moulded case circuit breaker (MCCB) designed for reliable protection and isolation of low-voltage electrical distribution systems. Configured as a fixed four-pole breaker with front terminals, it combines a 250 A rated current with ABB's electronic PR222DS/P-LSIG trip unit for comprehensive circuit protection.

Part of the ABB SACE Tmax T4 series, the T4V250 is engineered for industrial and commercial power distribution where high breaking capacity and flexible electronic protection are required. The PR222DS/P-LSIG release provides long-time, short-time, instantaneous and earth-fault protection functions, helping protect cables, equipment and distribution networks against overloads, short circuits and earth faults.

With its four-pole configuration, fixed installation and front terminals, the 1SDA054116R1 is suited to distribution boards, switchboards and industrial electrical panels. The T4V performance level provides an ultimate short-circuit breaking capacity of up to 200 kA at 380/415 V AC, making this breaker particularly suitable for installations where high prospective fault currents are present.

Key Advantages

  • High-performance ABB SACE Tmax T4V moulded case circuit breaker.
  • 250 A rated current for industrial and commercial power distribution.
  • Four-pole configuration for comprehensive circuit switching and protection.
  • Electronic PR222DS/P-LSIG trip unit with LSIG protection functions.
  • Ultimate breaking capacity of 200 kA at 380/415 V AC.
  • Fixed mounting with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax T4V 250 circuit breaker platform.
  • 250 A rated current.
  • 4-pole construction.
  • PR222DS/P-LSIG electronic release.
  • Long-time, short-time, instantaneous and ground-fault protection.
  • 200 kA Icu at 380/415 V AC.
  • Fixed circuit breaker configuration.
  • Front-terminal connection arrangement.
  • Designed for low-voltage power distribution protection.

Reliable Circuit Protection for Power Distribution

Moulded case circuit breakers such as the ABB SACE Tmax T4V protect electrical distribution circuits against damaging overcurrents while providing a convenient means of circuit isolation. The high breaking capacity of the T4V version enables it to interrupt substantial prospective short-circuit currents, supporting dependable protection in demanding industrial power systems.

The PR222DS/P-LSIG electronic trip unit adds adjustable electronic protection to the robust Tmax platform. Its LSIG functions provide protection against overload, short-time and instantaneous short-circuit conditions and earth faults, allowing the breaker to be coordinated with the requirements of the electrical distribution network.

Typical Applications

  • Industrial low-voltage distribution systems.
  • Main and sub-distribution switchboards.
  • Electrical control and distribution panels.
  • Commercial building power distribution.
  • Manufacturing and process installations.
  • Machinery and plant electrical distribution.

Technical Specifications

Series SACE Tmax T4
ABB order code 1SDA054116R1
Product group 310511-T-Max T4 - T8
Product type Moulded case circuit breaker (MCCB)
Frame T4 250
Rated current 250 A
Number of poles 4
Trip unit PR222DS/P-LSIG electronic release
Protection functions Long-time, short-time, instantaneous and ground-fault (LSIG)
Ultimate breaking capacity (Icu) at 220/230 V AC 200 kA
Ultimate breaking capacity (Icu) at 380/415 V AC 200 kA
Ultimate breaking capacity (Icu) at 440 V AC 180 kA
Ultimate breaking capacity (Icu) at 500 V AC 150 kA
Ultimate breaking capacity (Icu) at 690 V AC 80 kA
Mounting type Fixed
Terminal type Front terminals
Dimensions (H × W × D) approx. 205 × 140 × 103.5 mm
Weight approx. 3.84 kg

Frequently Asked Questions

What is the ABB 1SDA054116R1 used for?

The ABB 1SDA054116R1 is a 250 A moulded case circuit breaker designed to protect low-voltage electrical distribution circuits against overloads, short circuits and earth faults.

What is the current rating of the ABB T4V250 1SDA054116R1?

The circuit breaker has a rated current of 250 A and uses an ABB PR222DS/P-LSIG electronic trip unit.

What protection functions does the PR222DS/P-LSIG provide?

The PR222DS/P-LSIG electronic release provides long-time, short-time, instantaneous and ground-fault protection functions, commonly abbreviated as LSIG.

What is the breaking capacity of the ABB 1SDA054116R1?

The T4V version provides an ultimate short-circuit breaking capacity of 200 kA at 380/415 V AC, with breaking capacity varying according to the system operating voltage.

How is the ABB 1SDA054116R1 installed?

This model is a fixed four-pole circuit breaker with front terminals, designed for installation in electrical distribution panels and switchboards.

Trusted Protection from ABB

ABB SACE Tmax moulded case circuit breakers are engineered for dependable low-voltage power distribution, combining robust switching performance with flexible protection functions for industrial and commercial electrical systems.