ABB 1SDA054114R1 is a four-pole fixed SACE Tmax T4V 250 moulded case circuit breaker with front terminals, a 100 A PR222DS/P-LSIG electronic trip unit and 200 kA ultimate breaking capacity at 380–415 V AC.
£3,101.39
The ABB 1SDA054114R1 is a SACE Tmax T4V 250 four-pole moulded case circuit breaker designed for demanding low-voltage power distribution applications. It combines the high-breaking-capacity T4V platform with a 100 A PR222DS/P-LSIG electronic trip unit, providing electronic protection against overload, short-circuit and ground-fault conditions.
The PR222DS/P-LSIG electronic release provides long-time, short-time, instantaneous and ground-fault protection functions. This LSIG protection package extends conventional overcurrent protection with dedicated ground-fault functionality, supporting comprehensive protection and coordination within suitably engineered industrial, commercial and infrastructure distribution systems.
The 1SDA054114R1 features a fixed four-pole construction with front terminals and a rated operational voltage of up to 690 V AC. Its T4V performance level delivers an ultimate short-circuit breaking capacity of 200 kA at 380–415 V AC, providing substantial fault-interruption capability for installations with high prospective short-circuit currents.
The PR222DS/P-LSIG electronic trip unit provides four principal protection functions. Long-time protection responds to sustained overloads, short-time protection addresses higher fault currents while supporting selective coordination, instantaneous protection provides rapid interruption of severe short circuits, and ground-fault protection adds dedicated protection against earth-fault conditions.
Combined with the T4V platform's 200 kA ultimate breaking capacity at 380–415 V AC, the 100 A electronic release makes the ABB 1SDA054114R1 suitable for demanding distribution systems requiring sophisticated protection and very high fault-interruption capability. Its four-pole construction further supports applications where switching and protection across four conductors are required.
| Series | SACE Tmax T |
|---|---|
| Order code | 1SDA054114R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Frame / subtype | T4V 250 |
| Number of poles | 4 |
| Rated current (In) | 100 A |
| Rated uninterrupted current (Iu) | 250 A |
| Trip unit | PR222DS/P-LSIG |
| Trip technology | Electronic |
| Protection functions | LSIG – long-time, short-time, instantaneous and ground fault |
| Rated operational voltage (Ue) | up to 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Ultimate breaking capacity (Icu) at 220/230 V AC | 200 kA |
| Ultimate breaking capacity (Icu) at 380/400/415 V AC | 200 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 180 kA |
| Ultimate breaking capacity (Icu) at 500 V AC | 150 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 80 kA |
| Service breaking capacity (Ics) at 380/400/415 V AC | 200 kA |
| Service breaking capacity (Ics) at 440 V AC | 180 kA |
| Service breaking capacity (Ics) at 500 V AC | 150 kA |
| Service breaking capacity (Ics) at 690 V AC | 150 kA |
| Installation | Fixed circuit breaker |
| Terminal connection | Front |
| Electrical durability | 8,000 cycles |
| Mechanical durability | 20,000 cycles |
| Power loss at rated operating conditions | 1.7 W per pole |
| Test voltage | 3500 V |
| Product group | Tmax T4–T8 |
The ABB 1SDA054114R1 is a SACE Tmax T4V 250 four-pole fixed moulded case circuit breaker with front terminals and a 100 A PR222DS/P-LSIG electronic trip unit.
The LSIG designation identifies long-time, short-time, instantaneous and ground-fault protection, providing electronic protection against overload, short-circuit and earth-fault conditions.
The PR222DS/P-LSIG electronic trip unit fitted to the ABB 1SDA054114R1 has a rated current of 100 A, while the T4V 250 breaker platform has a rated uninterrupted current of 250 A.
The T4V 250 provides an ultimate short-circuit breaking capacity of 200 kA at 380–415 V AC. Additional Icu ratings include 200 kA at 220/230 V AC, 180 kA at 440 V AC, 150 kA at 500 V AC and 80 kA at 690 V AC.
Yes. The ABB 1SDA054114R1 is a four-pole fixed MCCB with front terminals, designed for integration into compatible low-voltage switchboards and distribution assemblies.
ABB SACE Tmax moulded case circuit breakers combine high short-circuit interruption capability with electronic trip technology, providing dependable protection for demanding industrial, commercial and infrastructure low-voltage distribution systems.